This study presents a high-gain broadband balanced homodyne detector, utilizing cascade amplification to generate continuous-variable quantum random numbers. The innovative approach of distributed parameter circuit analysis and optimization simulation is introduced into the circuit design of the broadband balanced homodyne detector. The objective is to enhance the transmission attributes of the ultra-high-frequency circuit. This is realized by optimally combining different elements and selecting key electronic components, guided by system stability indicators. Hence, a balanced homodyne detector was developed with a bandwidth surpassing 1.65 GHz and gain flatness of ±2 dB within the 0.2?930 MHz range. This study proposes a novel design perspective for broadband balanced homodyne detectors. The enhanced features of the detectors facilitate a more efficient derivation of continuous-variable quantum state random entropy sources, thereby propelling the rate enhancement and practical advancement of continuous-variable quantum random number generators.
This study presents a high-gain broadband balanced homodyne detector, utilizing cascade amplification to generate continuous-variable quantum random numbers. The innovative approach of distributed parameter circuit analysis and optimization simulation is introduced into the circuit design of the broadband balanced homodyne detector. The objective is to enhance the transmission attributes of the ultra-high-frequency circuit. This is realized by optimally combining different elements and selecting key electronic components, guided by system stability indicators. Hence, a balanced homodyne detector was developed with a bandwidth surpassing 1.65 GHz and gain flatness of ±2 dB within the 0.2?930 MHz range. This study proposes a novel design perspective for broadband balanced homodyne detectors. The enhanced features of the detectors facilitate a more efficient derivation of continuous-variable quantum state random entropy sources, thereby propelling the rate enhancement and practical advancement of continuous-variable quantum random number generators.
True random numbers are extracted through measurements of vacuum fluctuations in quantum state components. We propose an improved scheme utilizing an optimization-based simulation methodology to enhance the temporal resolution of quantum state detection and processing efficiency of vacuum fluctuation signals in continuous-variable quantum random number generators (CV-QRNGs), while simultaneously maximizing the entropy content of quantum noise sources. This work presents the first application of optimization simulation methodology to balanced homodyne detector (BHD) circuit design, with particular emphasis on improving high-frequency transmission characteristics. The design framework prioritizes system stability and S-parameter sensitivity to optimize both circuit architecture and critical component parameters. The AC amplifier circuit was implemented through ADS high-frequency simulations using two ABA-52563 RF amplifiers in a cascaded configuration, with circuit modeling performed on Rogers 4350 substrate optimized for high-frequency applications. This approach enabled the development of a switched-configuration BHD featuring: 1) 1.9 GHz bandwidth, 2) 41.5 dB signal-to-noise ratio at 1.75 GHz, 3) 30 dB common-mode rejection ratio at 100 MHz, and 4) frequency response flatness within 1.5 dB across 1.3-1.7 GHz. Additionally, the Husimi function is employed for entropy analysis to reconstruct vacuum state phase-space distributions, validating the detector's quantum measurement fidelity. The implemented system demonstrates a collective generation rate of 20.0504 Gbps across four parallel channels, with all output streams successfully passing NIST SP 800-22 statistical testing requirements.
In this paper, a model for simulating the shot noise power and the electronic noise power of a balanced homodyne detector (BHD) using cascaded low noise amplifiers (LNAs) is presented. Moreover, the factors influencing the enhancement of BHD gain flatness are analyzed. Based on these theories, a BHD with a large clearance between shot noise and electronic noise, along with a flat broadband frequency response, is designed using LNAs and an optimized printed circuit board design. According to the experimental measurements, the bandwidth for 1 dB flatness reaches 1.4 GHz with the -3 dB bandwidth extending up to 1.55 GHz. With a 4 mW optical signal input, a signal-to-noise ratio of 12 dB is obtained at 1 GHz. The BHD exhibits excellent linearity for shot noise output up to an 8 mW optical signal input and a tested common mode rejection ratio of 63 dB. This developed BHD is well-suited for applications in high-speed continuous variable quantum key distribution and quantum random number generation.
Balanced homodyne detector (BHD) that can measure the field quadratures of coherent states has been widely used in a range of quantum information technologies. Generally, the BHD tends to suffer from narrow bands and an expanding bandwidth behavior usually traps into a compromise with the gain, electronic noise, and quantum to classical noise ratio, etc. In this paper, we design and construct a wideband BHD based on radio frequency and integrated circuit technology. Our BHD shows bandwidth behavior up to 1.2 GHz and its quantum to classical noise ratio is around 18 dB. Simultaneously, the BHD has a linear performance with a gain of 4.86 k and its common mode rejection ratio has also been tested as 57.9 dB. With this BHD, the secret key rate of continuous-variable quantum key distribution system has a potential to achieve 66.55 Mb/s and 2.87 Mb/s, respectively, at the transmission distance of 10 and 45 km. Besides, with this BHD, the generation rate of quantum random number generator could reach up to 6.53 Gb/s.
ObjectiveHigh performance balanced homodyne detectors with high bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio are critical in the fields of high-speed quantum communication, broadband squeezed light and entangled light detection, and broadband quantum precision measurement. However, it is challenging to design and develop GHz bandwidth balanced homodyne detectors with overall high performance. For example, the actually achieved bandwidth and gain are usually limited by the distributed capacitance of the circuit board. Furthermore, high common-mode rejection ratio, linear response and low noise performance are also technically challenging due to fabrication and soldering processes of the printed circuit board (PCB).MethodsIn comparison with other high bandwidth balanced homodyne detectors developed in previous works, we have adopted a design that separates alternating current (AC) and direct current (DC). The DC output helps us monitor the optical power and ensures the balance of the two photodiodes, which is crucial for balanced homodyne detection in quantum optical experiments. Our circuit board design involves placing two photodiodes on opposite sides of the PCB. This makes it easier to ensure the circuit lengths of the two photodiodes are exactly the same and reduce the distributed capacitance of the circuit board. This is important for enhancing the detector bandwidth and improving the common-mode rejection ratio. Additionally, this design is more convenient for quantum optical experiment operations.Results and DiscussionsWe used two photodiodes with 95% quantum efficiency, low capacitance and dark current for our balanced homodyne detector. The DC gain of the balanced homodyne detector is 1003.6 V/W, which is at a reasonable level for optical power monitor. We also took the noise power spectra of the balanced homodyne detector at different optical powers. We demonstrate the detector response is linear at five different frequencies. An effective bandwidth of 1 GHz and a maximum signal-to-noise ratio of 12 dB were realized at 1550 nm. The common-mode rejection ratio of the homodyne detector was tested by modulating the input beam with an electro-optical modulator. By placing two photodiodes symmetrically on the front and back sides of the double-sided PCB board, a common-mode rejection ratio of 60.65 dB at 20 MHz was achieved. Subsequently, the balanced homodyne detector was used to measure 1550 nm quadrature amplitude squeezed light. Up to -2.5 dB squeezing was observed over a bandwidth range from 3.5 MHz to 71.5 MHz.ConclusionsIn this paper, we designed and developed a balanced homodyne detector with GHz bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio. The results show that the balanced homodyne detector with high bandwidth and high common-mode rejection ratio are useful in broadband squeezed state measurement.
Objective The balanced homodyne detector (BHD) is widely used in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous-variable quantum key distribution, and quantum random number generation. Highly sensitive to the amplitude and phase of the incident light, the BHD can reliably extract quantum fluctuations, suppress the classical common-mode noise, and amplify quantum fluctuations to the macro level. However, the performance of the BHD is limited by the bandwidth, signal-to-noise ratio (SNR), and common-mode rejection ratio (CMRR) of the detector. The optimal design of the BHD has always been a research hotspot. The transimpedance circuit based on a direct current (DC) coupled circuit is not suitable for detecting quantum noise. The reason is that as the power of the incident light increases, the unbalanced DC increases rapidly, and the transimpedance amplifier is saturated, which significantly reduces the dynamic range of the BHD. The BHD based on an inductor-capacitor (L-C) coupled circuit generates higher electronic noise at an analyzing frequency in the kHz range. It is not suitable for low-frequency measurements due to the parasitic effect of the inductor and the low impedance of the inductor at an analyzing frequency in the kHz range. In this paper, the noise sources of the BHD are analyzed theoretically, and a resistor-capacitor (R-C) coupled transimpedance circuit is used to improve the performance of the BHD at an analyzing frequency in the kHz range. Furthermore, the transimpedance circuit is optimized to increase the bandwidth to 200 MHz. The CMRR of the BHD is improved by designing a self-subtraction photodetector scheme, a variable optical attenuator, and an adjustable reverse bias voltage. These designs allow the BHD to meet the low-frequency and high-frequency measurements with high SNR and CMRR in quantum noise measurement. Methods To enable the BHD to measure both low-frequency and high-frequency signals with high sensitivity, this paper adopts the BHD based on an R-C coupled transimpedance circuit. Two photodiodes are connected in series, and the balanced current signal in the two photodiodes is divided into a DC signal and an alternating current (AC) signal by the R-C coupled structure. The AC signal is converted into a voltage signal by a transimpedance amplifier (TIA) and is further used to measure the shot-noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and is then used to measure the balance between the two incident lights. To reduce the crosstalk between the DC circuit and the AC circuit, an isolation amplifier is added after the load resistor. An adjustable bias voltage (BV) circuit is used to adjust the junction capacitance of the photodiodes and further improve the CMRR. To compensate for the difference in the amplitude of the two photodiodes and thereby improve the CMRR of the BHD, the paper also utilizes a variable optical attenuator based on fiber bending, where variable attenuation is achieved by changing the radius of the bent fiber. The attenuation of the fiber is precisely adjusted to balance the photocurrent. In addition, an equivalent noise model is constructed. The electronic noise from the TIA circuit includes four parts, i.e., the noise introduced by the dark current in the photodiodes, the thermal noise in the feedback resistor, the noise generated by the input current noise in the TIA, and the noise produced by the input voltage noise. On the basis of theoretical analysis, reasonable DC load resistance and feedback capacitance, photodiodes with low dark current and low junction capacitance, and a TIA with low input noise are selected to reduce the electronic noise and improve the SNR of the BHD. Results and Discussions A BHD with an R-C coupled circuit structure is designed (Fig. 1). A test device is built to test the performance of the BHD. The AC output is connected with a spectrometer to measure the bandwidth and the SNR of the BHD. The DC output is connected with an oscilloscope to make sure that the power of the two incident lights is balanced (Fig. 3). When the incident optical power is 8, 4, 2, and 1 mW, respectively, the paper tests the shot-noise spectrum and the electronic noise spectrum of the BHD with different analyzing frequencies. The test results show that the 3-dB bandwidth of the BHD is 1 kHz-200 MHz. The resolution bandwidth (RBW) and the video bandwidth (VBW) of the spectrum analyzer are set to 10 Hz and 1 Hz, respectively, and the number of averaging times is set to 40. In this case, the SNR is 12 dB at the analyzing frequency of 5 kHz under an incident optical power of 8 mW. The SNR is 20 dB at the analyzing frequency of 100 MHz when the RBW is 200 kHz and the VBW is 100 Hz. Moreover, in the analyzing frequency range of 10 kHz-200 MHz, the shot-noise power decreases by about 3 dB when the incident optical power decreases by half, indicating that the AC output of the BHD has favorable linear gain characteristics in the range of 1 mW to 8 mW (Fig. 4). In addition, 5 kHz and 100 MHz sinusoidal signals are loaded into an electro-optical amplitude modulator to modulate the incident light and thereby test the CMRR. The results show that the CMRR is 70 dB at the analyzing frequency of 5 kHz and 66 dB at the analyzing frequency of 100 MHz (Fig. 5). Conclusions By analyzing the noise sources of the BHD, adopting the R-C coupled transimpedance circuit, and optimizing the TIA circuit, this paper implements a broadband balanced homodyne detector that works in the bandwidth range from 1 kHz to 200 MHz with low noise and high CMRR. In the case of an incident optical power of 8 mW@1550 nm, the shot-noise power is 12 dB higher than the electronic noise power and the CMRR reaches 70 dB at the analyzing frequency of 5 kHz, and the shot-noise power is 20 dB higher than the electronic noise power and the CMRR reaches 66 dB at the analyzing frequency of 100 MHz. Such a homodyne detector can serve as a high-performance detection tool in various applications, such as low-frequency gravitational wave detection, high-speed continuous-variable quantum key distribution, and high-speed quantum random number generation.
We present a high-performance, fully discrete balanced homodyne detector (BHD) with a 2.5 GHz bandwidth, exceptional gain flatness, and superior common-mode rejection ratio. The design leverages a Rogers 4350B-based printed circuit board, a broadband multi-section RF choke bias network, and inter-stage π-section attenuators, complemented by precise photodiode matching and phase-magnitude compensation to ensure signal integrity and suppress common-mode noise. Experimental results show a -3 dB bandwidth of 2.5 GHz and 1 dB gain flatness up to 2.4 GHz-significantly exceeding our prior 1.55 GHz/1.4 GHz implementation and representing state-of-the-art performance among discrete BHDs. At 16 mW optical input, the detector delivers a 16.5 dB signal-to-noise ratio at 2 GHz while maintaining excellent linearity, and achieves a 66 dB common-mode rejection ratio at the same frequency. This cost-effective and flexible BHD is ideally suited for high-speed continuous-variable quantum key distribution and quantum random number generation.