It is shown that the canonical correlation method used with the intrinsic degrees of coherence (IDOCs) to describe coherence properties of partially polarized light is effective to identify relevant properties of the photo-detection correlations of a two-photon source described with its density operator. The results are compared with other global correlation measures.
It is shown that the canonical correlation method used with the intrinsic degrees of coherence (IDOCs) to describe coherence properties of partially polarized light is effective to identify relevant properties of the photo-detection correlations of a two-photon source described with its density operator. The results are compared with other global correlation measures.
Measurements have been made of the distribution in time of arrival of photons produced in a low-pressure Hg198 discharge. Sufficient calibration was done so that the measurements could be directly compared with the predictions of a calculation of G(2)(x1,x2,x2,x1), the second-order coherence function. Correlations were observed in a mixture of light from two independent sources and between orthogonally polarized components of a beam initially in a pure polarization state.
Coherence and correlations represent two related properties of a compound system. The system can be, for instance, the polarization of a photon, which forms part of a polarization-entangled two-photon state, or the spatial shape of a coherent beam, where each spatial mode bears different polarizations. Whereas a local unitary transformation of the system does not affect its coherence, global unitary transformations modifying both the system and its surroundings can enhance its coherence, transforming mutual correlations into coherence. The question naturally arises of what is the best measure that quantifies the correlations that can be turned into coherence, and how much coherence can be extracted. We answer both questions, and illustrate its application for some typical simple systems, with the aim at illuminating the general concept of enhancing coherence by modifying correlations.
We measure the recently introduced electromagnetic temporal degree of coherence of a stationary, partially polarized, classical optical beam. Instead of recording the visibility of intensity fringes, the spectrum, or the polarization characteristics, we introduce a novel technique based on two-photon absorption. Using a Michelson interferometer equipped with polarizers and a specific GaAs photocount tube, we obtain the two fundamental quantities pertaining to the fluctuations of light: the degree of coherence and the degree of polarization. We also show that the electromagnetic intensity-correlation measurements with two-photon absorption require that the polarization dynamics, i.e., the time evolution of the instantaneous polarization state, is properly taken into account. We apply the technique to unpolarized and polarized sources of amplified spontaneous emission (Gaussian statistics) and to a superposition of two independent, narrow-band laser beams of different mid frequencies (non-Gaussian statistics). For these two sources femtosecond-range coherence times are found that are in good agreement with the traditional spectral measurements. Although previously employed for laser pulses, two-photon absorption provides a new physical principle to study electromagnetic coherence phenomena in classical and quantum continuous-wave light at extremely short time scales.
Optical parametric down-conversion is a common source for the generation of nonclassical correlated photonic states. Using a parametric down-conversion source and photon-number-resolving detectors, we measure the two-mode photon-number distribution of up to 10 photons for different degrees of correlation. The degree of correlation is controlled by collecting different spatial and spectral single modes for each polarization and varying the amount of spectral and spatial overlap between them. Clear evidence for photon-number correlations is presented despite detector imperfections such as low detection efficiency and other distorting effects. Two criteria, derived directly from the raw data, are shown to be good measures for the degree of correlation. Additionally, using a fitting technique, we find a connection between the measured photon-number distribution and the degree of correlation of the reconstructed original two-mode state. These observations are only possible as a result of the detection of high photon number events.
Two-photon correlation measurement provides a promising way to experimentally demonstrate the statistical nature of a light source, which is very significant for the deep understanding of the photon-generating process and the diagnosing of the coherence property. Quantitatively two- photon correlation is described by second-order coherence. Usually the behavior of the second-order coherence against any of the parameters defining the phase volume is different for different photon statistics. The Poisson photon statistics for coherent light gives its second-order coherence as a flat response; The Bose-Einstein photon statistics for chaotic light gives its second-order coherence as a bunching effect; While the Sub-Poisson photon statistics for non-classical light gives its second-order coherence as an anti-bunching effect. Therefore the measurement of two-photon correlation is proved to be a good finger print to check whether light is in coherent state or incoherent state such as thermal state or non-classical state. Historically the measurement of two-photon correlation was first performed by Hanbury-Brown and Twiss (HBT) in 1956. They used a linear mixer to realize the correlation of the two currents from the photoelectric detectors illuminated by a stationary thermal light souece, a mercury arc, and the photo-bunching effect was first successfully observed in the visible region of 435.8 nm. HBT method is no doubt a good way to extract the small excess two-photon correlation for a stationary light because the background, that is the DC components, has been cut off automatically by the broad band amplifiers, which is in fact the key of the success of HBT experiment. However there exists a general problem, to which no attention has ever been paid, in measuring the two-photon correlation of non-stationary light such as synchrotron radiation (SR) by the HBT method. Here the "non-stationary" means a sense of classical mechanics that the observed intensity has some deterministic time structure. The systematic time structure of SR decided by the bunch distribution of the electric current in a storage ring will give rise to a large amount of unexpected accidental correlation, which in fact has nothing to do with the inherent photon statistics of light source and usually l000~l0000 times larger than the true two-photon correlation due to the short bunch separation length (2ns) and the short coherence time (~0.1ps) which is not comparable to the time resolution (1ns) of the measuring system. The existence of the accidental correlation would severely prevent us from observing the bunching effect of the true two-photon correlation. Therefore to suppress the much larger accidental correlation and to extract the small true two-photon correlation, a novel intensity interferometer has been developed for soft X-ray synchrotron radiation. This intensity interferometer consists of an optical vacuum chamber and an electric correlator. All the essential optical elements which includes a wire scanner, a precise diffraction slit, a grating monochromator with a coherence time modulator, a beam divider and two fast-response photon detectors (microchannel plates) are mounted in this high vacuum chamber. The electric correlator completes the multiplication of the two broad band electric currents coming from the photoelectric detectors. The basic idea to suppress the much larger accidental correlation is to modulate the coherence time by modulating the entrance slit width of the monochromator by a piezoclectric translator. The two sets of light intensity are simultaneously modulated too. When the frequency of modulation is f, the third harmonics 3f is detected with a loch-in amplifier because the 3f components include only the true two-photon correlation. Practically it is difficult to modulate with frequency f without any higher order harmonics distortion which might add some false 3f components. To overcome this difficulty we have used a sharp bandpass filter of l00~350 MHz in each branch of the correlator, which is lower than the RF frequency 500 MHz and much higher than 1.6 MHz, the revolution frequency of the stored beam of the 2.5 GeV storage ring. This new apparatus has been operated successfully in the measurement of the horizontal two-photon correlation for the first harmonic of undulator radiation with photon energy of 70 eV at the Photon Factory, KEK. By narrowing the precise slit width which correspondingly changes the spatial coherence of the incident SR, a bunching effect of the normalized excess two-photon correlation has been clearly observed. This explicit bunching effect implies that synchrotron radiation is chaotic radiation. Further investigation shows that although second-order coherence is completely determined by the first-order coherence for the case of chaotic light, the measured information from the light source is essentially different. The two-photon correlation of synchrotron radiation does not depend on the response time of the detectors but gives the information of instantaneous emittance of the stored beam with the time scale of coherence time τC. By fitting the experimental data, the horizontal instantaneous emittance of the stored beam is estimated to be 40nmrad. This intensity interferometer can be utilized to characterize the coherence properties of incomplete FELs, such as SASE, because if they are fully coherent light sources the normalized excess two-photon correlation would have a flat response, but not showing a photon-bunching effect.
Abstract A theoretical analysis is given of the correlation to be expected between the fluctuations in the outputs of two photoelectric detectors when these detectors are illuminated with partially coherent light. It is shown how this correlation depends upon the parameters of the equipment and upon the geometry of the experiment. The correlation may be detected either by linear multiplication of the fluctuations in the two outputs or by a coincidence counter which counts the simultaneous arrival of photons at the detectors. The theory is given for both these techniques and it is shown that they are closely equivalent. A laboratory test is described in which two photomultipliers were illuminated with partially coherent light and the correlation between the fluctuations in their outputs measured as a function of the degree of coherence. The results of this experiment are compared with the theory and it is shown that they agree within the limits of accuracy of the test; it is concluded that if there is any systematic error in the theory it is unlikely to exceed a few parts per cent.