Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Mitigating unbalanced loss in entanglement assisted absorptive measurements with a phase-sensitive amplifier

Wei Du, Shidong Bao, Peiyu Yang, Yiquan Yang, Shuhe Wu, Jinxian Guo, Guzhi Bao, Weiping Zhang

Published Nov 15, 2024• 0 citations
Publisher

Abstract

Correlated interferometry offers various advantages in precision measurements, such as sub-shot noise sensitivity, high resolution, and prevention of detector saturation benefiting from dark output. In certain practical scenarios, e.g. absorptive measurement, there is usually unbalanced loss between the probe and reference beams, which destroys the correlation and remains a significant obstacle in the efficient application of entanglements. Here, we study the performance of a nonlinear interferometer whose arms experience unbalanced loss and demonstrate the use of a phase-sensitive amplifier in the sensing or reference arms to amplify or squeeze the light field, which can both reduce the degradation of quantum enhancement from unbalanced absorption in a lossy environment. We find that the loss after amplification, i.e. from imperfect interferometry and detection, can be mitigated when the phase-sensitive amplifier is placed at the sensing arm and functions as a noiseless amplifier. Our approach may be helpful to the practical application of quantum-enhanced absorptive measurement.

DOI
10.1364/oe.543620

Related papers

Efficient phase-sensitive compensation in lossy interferometry using optical amplification

Tingting Jiang, Jie Zhao, Feiyu Yao +5 more

Optical interferometers, as precision measurement tools, inevitably experience optical path losses in practical applications, which introduce unavoidable vacuum noise and reduce the sensitivity in the phase estimation. To mitigate the effects of losses on sensitivity, we propose an enhanced interferometer scheme that integrates a Raman amplifier. This amplifier is strategically positioned within the lossy interference arm to counteract the reduction in phase sensitivity caused by losses. Our research highlights the crucial role of amplifier positioning, revealing that pre-amplification (PRA, placing the amplifier before the lossy section) significantly outperforms post-amplification (POA, placing the amplifier after the lossy section). PRA effectively enhances sensitivity by increasing the number of phase-sensitive particles and minimizing noise amplification. As the loss increases, the superiority of PRA in mitigating loss effects becomes increasingly evident. To validate our approach, we conducted experimental demonstrations. When the losses reach 90%, PRA experimentally achieves a sensitivity improvement of 4.6 dB compared with the case of only loss without the amplifier, equivalent to increasing the input laser power by over 8 times. PRA can effectively improve the robustness against losses for the practical application solely through the use of a coherent amplifier, with a simple technical implementation yet remarkable enhancement effects. We believe that current PRA-enhanced interferometry facilitates the practical implementation of phase measurement in environments characterized by significant loss.

Optics Express•Apr 2, 2025•2 citations

Coherent Amplifier-Empowered Quantum Interferometer: Preserving Sensitivity and Quantum Advantage under High Loss

Jie Zhao, Zeliang Wu, Haoran Liu +6 more

Quantum interferometers offer phase measurement capabilities that surpass the standard quantum limit (SQL), with phase sensitivity and quantum enhancement factor serving as key performance metrics. However, practical implementations face severe degradation of both metrics due to unavoidable losses, representing the foremost challenge in advancing quantum interferometry toward real-world applications. To address this challenge, we propose a coherent-amplifier-empowered quantum interferometer. The coherent amplifier dramatically suppresses the decay of both sensitivity and quantum enhancement under high-loss conditions, maintaining phase sensitivity beyond the original SQL even for losses exceeding 90%. Using an injected 4.2 dB squeezed-vacuum state in experimental demonstration, our scheme reduces the quantum enhancement degradation under 90% loss from 3.7 dB in a conventional quantum interferometer (CQI) to only 1.5 dB. More importantly, the phase sensitivity degradation under the same loss is limited to 4.0 dB, markedly outperforming the 11.2 dB degradation observed in a CQI. This improvement is enabled by the coherent amplifier's phase-sensitive photon amplification and its protection of the quantum state. This breakthrough in amplifier-empowered quantum interferometry overcomes the critical barrier to practical deployment, enabling robust quantum-enhanced measurements in lossy environments.

quant-pharXiv:2601.17876•Jan 27, 2026•0 citations

Overcoming detection inefficiency in squeezing-assisted interferometers

Gaetano Frascella, Sascha Agne, Farid Ya Khalili +1 more

Squeezing-assisted interferometers achieve sub-shot-noise sensitivity to phase shifts, but losses can strongly degrade their performance. Here we present the first experimental demonstration of detection-loss tolerance for this class of interferometers employing degenerate optical parametric amplification at one output port. For $50\%$ detection efficiency, the phase sensitivity of any interferometer with coherent and squeezed vacuum inputs would not overcome the shot-noise limit, but in our case the output amplification gives $6$ dB sub-shot-noise sensitivity. We further demonstrate that robustness increases with higher gain of the output amplifier: sub-shot-noise sensitivity is achieved for detection efficiency as low as $13\%$. We believe that overcoming detection inefficiency will become crucial to take full advantage of quantum metrology, for example in gravitational-wave detection, quantum sensing and imaging.

•May 18, 2020•0 citations

Loss-tolerant interferometry with squeezed light

Maria V. Chekhova, Gaetano Frascella, Sascha Agne +1 more

An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.

Emerging Imaging and Sensing Technologies for Security and Defence; and Advanced Manufacturing Technologies for Micro- and Nanosystems in Security and Defence•Sep 18, 2020•0 citations

Detection Loss Tolerant Supersensitive Phase Measurement with an SU(1,1) Interferometer

Mathieu Manceau, Gerd Leuchs, Farid Ya Khalili +1 more

In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.

arXiv:1705.02662•Physical Review Letters•Nov 29, 2017•171 citations

Nonlinear Interferometry for Quantum-Enhanced Measurements of Multiphoton Absorption

S. Panahiyan, Carlos Sánchez Muñoz, Maria V. Chekhova +1 more

Multiphoton absorption is of vital importance in many spectroscopic, microscopic, or lithographic applications. However, given that it is an inherently weak process, the detection of multiphoton absorption signals typically requires large field intensities, hindering its applicability in many practical situations. In this Letter, we show that placing a multiphoton absorbent inside an imbalanced nonlinear interferometer can enhance the precision of multiphoton cross section estimation with respect to strategies based on photon-number measurements using coherent or even squeezed light directly transmitted through the medium. In particular, the power scaling of the sensitivity with photon flux can be increased by 1 order compared with transmission measurements of the sample with coherent light, such that the measurement precision at any given intensity can be greatly enhanced. Furthermore, we show that this enhanced measurement precision is robust against experimental imperfections leading to photon losses, which usually tend to degrade the detection sensitivity. We trace the origin of this enhancement to an optimal degree of squeezing which has to be generated in a nonlinear SU(1,1) interferometer.

arXiv:2209.02697•Physical Review Letters•May 19, 2023•22 citations
Correlated interferometry offers various advantages in precision measurements, such as sub-shot noise sensitivity, high resolution, and prevention of detector saturation benefiting from dark output. In certain practical scenarios, e.g. absorptive measurement, there is usually unbalanced loss between the probe and reference beams, which destroys the correlation and remains a significant obstacle in the efficient application of entanglements. Here, we study the performance of a nonlinear interferometer whose arms experience unbalanced loss and demonstrate the use of a phase-sensitive amplifier in the sensing or reference arms to amplify or squeeze the light field, which can both reduce the degradation of quantum enhancement from unbalanced absorption in a lossy environment. We find that the loss after amplification, i.e. from imperfect interferometry and detection, can be mitigated when the phase-sensitive amplifier is placed at the sensing arm and functions as a noiseless amplifier. Our approach may be helpful to the practical application of quantum-enhanced absorptive measurement.
Optical interferometers, as precision measurement tools, inevitably experience optical path losses in practical applications, which introduce unavoidable vacuum noise and reduce the sensitivity in the phase estimation. To mitigate the effects of losses on sensitivity, we propose an enhanced interferometer scheme that integrates a Raman amplifier. This amplifier is strategically positioned within the lossy interference arm to counteract the reduction in phase sensitivity caused by losses. Our research highlights the crucial role of amplifier positioning, revealing that pre-amplification (PRA, placing the amplifier before the lossy section) significantly outperforms post-amplification (POA, placing the amplifier after the lossy section). PRA effectively enhances sensitivity by increasing the number of phase-sensitive particles and minimizing noise amplification. As the loss increases, the superiority of PRA in mitigating loss effects becomes increasingly evident. To validate our approach, we conducted experimental demonstrations. When the losses reach 90%, PRA experimentally achieves a sensitivity improvement of 4.6 dB compared with the case of only loss without the amplifier, equivalent to increasing the input laser power by over 8 times. PRA can effectively improve the robustness against losses for the practical application solely through the use of a coherent amplifier, with a simple technical implementation yet remarkable enhancement effects. We believe that current PRA-enhanced interferometry facilitates the practical implementation of phase measurement in environments characterized by significant loss.
Quantum interferometers offer phase measurement capabilities that surpass the standard quantum limit (SQL), with phase sensitivity and quantum enhancement factor serving as key performance metrics. However, practical implementations face severe degradation of both metrics due to unavoidable losses, representing the foremost challenge in advancing quantum interferometry toward real-world applications. To address this challenge, we propose a coherent-amplifier-empowered quantum interferometer. The coherent amplifier dramatically suppresses the decay of both sensitivity and quantum enhancement under high-loss conditions, maintaining phase sensitivity beyond the original SQL even for losses exceeding 90%. Using an injected 4.2 dB squeezed-vacuum state in experimental demonstration, our scheme reduces the quantum enhancement degradation under 90% loss from 3.7 dB in a conventional quantum interferometer (CQI) to only 1.5 dB. More importantly, the phase sensitivity degradation under the same loss is limited to 4.0 dB, markedly outperforming the 11.2 dB degradation observed in a CQI. This improvement is enabled by the coherent amplifier's phase-sensitive photon amplification and its protection of the quantum state. This breakthrough in amplifier-empowered quantum interferometry overcomes the critical barrier to practical deployment, enabling robust quantum-enhanced measurements in lossy environments.
Squeezing-assisted interferometers achieve sub-shot-noise sensitivity to phase shifts, but losses can strongly degrade their performance. Here we present the first experimental demonstration of detection-loss tolerance for this class of interferometers employing degenerate optical parametric amplification at one output port. For 50%50\%50% detection efficiency, the phase sensitivity of any interferometer with coherent and squeezed vacuum inputs would not overcome the shot-noise limit, but in our case the output amplification gives 666 dB sub-shot-noise sensitivity. We further demonstrate that robustness increases with higher gain of the output amplifier: sub-shot-noise sensitivity is achieved for detection efficiency as low as 13%13\%13%. We believe that overcoming detection inefficiency will become crucial to take full advantage of quantum metrology, for example in gravitational-wave detection, quantum sensing and imaging.
An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.
In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.
Multiphoton absorption is of vital importance in many spectroscopic, microscopic, or lithographic applications. However, given that it is an inherently weak process, the detection of multiphoton absorption signals typically requires large field intensities, hindering its applicability in many practical situations. In this Letter, we show that placing a multiphoton absorbent inside an imbalanced nonlinear interferometer can enhance the precision of multiphoton cross section estimation with respect to strategies based on photon-number measurements using coherent or even squeezed light directly transmitted through the medium. In particular, the power scaling of the sensitivity with photon flux can be increased by 1 order compared with transmission measurements of the sample with coherent light, such that the measurement precision at any given intensity can be greatly enhanced. Furthermore, we show that this enhanced measurement precision is robust against experimental imperfections leading to photon losses, which usually tend to degrade the detection sensitivity. We trace the origin of this enhancement to an optimal degree of squeezing which has to be generated in a nonlinear SU(1,1) interferometer.