Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics & Laser Technology

Response signal enhancement for single-beam SERF atomic magnetometer with magneto-optical misalignment phenomenon

Renjie Li, Ying Liu, Jiajie Li, Qian Cao, Binyue Huang, Yueyang Zhai

Published May 30, 2024• 11 citations
Publisher
DOI
10.1016/j.optlastec.2024.111217

Related papers

Comprehensive analysis of the impact of optical magnetic misalignment on the performance of the SERF co-magnetometer

Ze Yu Cai, Lihong Duan, Shimiao Fan +2 more

The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.

Optics Express•Apr 10, 2025•4 citations

Spin-feedback enhancement method for modulated dual-axis SERF atomic magnetometer

Yujian Ma, Ziqi Yuan, Shudong Lin +2 more

Measurement•Aug 18, 2026•0 citations

Single-Beam Atomic Magnetometer Enhanced With Elliptically Polarized Reflected Light

An‐Ning Xu, Jin Peng, Yiran Yin +1 more

The ultra-sensitivity magnetometer plays an important role in fundamental physics and applications, including magnetoencephalography (MEG) and magnetocardiography (MCG). The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has great sensitivity but is limited by the relatively complicated dual-beam structure for application, leading to the development of the compact AM based on one single laser beam. Compared with the single-beam optically pumped magnetometer (OPM) detecting the absorption of the circularly polarized beam, the SERF AM based on an elliptically polarized single beam detecting the optical rotation angle of polarization has a better response, lower laser power, and no need for signal modulation or demodulation. Here, we would like to report an elliptically-polarized single-beam SERF AM enhanced by reflecting the probe beam, increasing the light-atom interaction. Moreover, unlike the previous reflecting AM using the beam splitter, we used a D-shape mirror to extract the reflected beam, avoiding power losses of both incident and reflected beam and destruction of polarization. The sensitivity of our device in the reflecting scheme reaches 5 fT/Hz1/2 at 9–60 Hz, satisfying the need to measure the human MEG/MCG or search for the fifth force. Our research paves the way for developing the compact SERF AM for multiple future applications.

IEEE Sensors Journal•Jun 27, 2024•7 citations

High sensitivity detuned single-light-source orthogonal pump-probe SERF atomic magnetometer

Yuhao Wang, Ying Liu, Ziqian Yue +4 more

Optics and Lasers in Engineering•Feb 10, 2025•1 citation

Light shift cross-sectional distribution measurement and suppression in SERF atomic magnetometers

Yuhao Wang, Ziqi Yuan, Shudong Lin +4 more

Measurement•Oct 15, 2025•2 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•62 citations
The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.
The ultra-sensitivity magnetometer plays an important role in fundamental physics and applications, including magnetoencephalography (MEG) and magnetocardiography (MCG). The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has great sensitivity but is limited by the relatively complicated dual-beam structure for application, leading to the development of the compact AM based on one single laser beam. Compared with the single-beam optically pumped magnetometer (OPM) detecting the absorption of the circularly polarized beam, the SERF AM based on an elliptically polarized single beam detecting the optical rotation angle of polarization has a better response, lower laser power, and no need for signal modulation or demodulation. Here, we would like to report an elliptically-polarized single-beam SERF AM enhanced by reflecting the probe beam, increasing the light-atom interaction. Moreover, unlike the previous reflecting AM using the beam splitter, we used a D-shape mirror to extract the reflected beam, avoiding power losses of both incident and reflected beam and destruction of polarization. The sensitivity of our device in the reflecting scheme reaches 5 fT/Hz1/2 at 9–60 Hz, satisfying the need to measure the human MEG/MCG or search for the fifth force. Our research paves the way for developing the compact SERF AM for multiple future applications.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.