Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement

Light shift cross-sectional distribution measurement and suppression in SERF atomic magnetometers

Yuhao Wang, Ziqi Yuan, Shudong Lin, Yi Xu, Junjian Tang, Yueyang Zhai, Ying Liu

Published Oct 15, 2025• 2 citations
Publisher
DOI
10.1016/j.measurement.2025.119325

Related papers

Measurement and suppression of tensor light shift for nonlinear magneto-optical rotating atomic magnetometers

Mengnan Tian, Liwei Jiang, Yanchao Chai +5 more

Sensors and Actuators A Physical•Apr 21, 2025•2 citations

Suppression of light shift in dual-pump three-axis vector atomic magnetometers

Lin Li, Junjian Tang, Binbin Zhao +1 more

Optics & Laser Technology•Aug 7, 2023•2 citations

Analysis and suppression of the three-axis crosstalk effect in the modulated SERF atomic magnetometer

Lin Li, Junjian Tang, Binbin Zhao +3 more

Measurement•Jun 7, 2023•20 citations

Transverse light-shift in a spin-exchange relaxation-free co-magnetometer: measurement, decoupling, and suppression

Sixun Liu, Ruigang Wang, Linlin Yuan +6 more

The transverse light-shift can induce non-negligible polarization error in the output signal of spin-exchange relaxation-free (SERF) co-magnetometer. In this paper, a novel method for rapid measurement of transverse light-shift based on the error of steady-state response of co-magnetometer is proposed firstly, then the sources of transverse light-shift in a compact SERF co-magnetometer is modeled and analyzed from three aspects: the non-ideal linear polarization of probe laser, the circular dichroism of the atomic spin ensembles, and the stress-induced birefringence effect of the cell wall. Furthermore, the decoupling and suppression methods of transverse light-shift based on a degree of circular polarization (DOCP) regulation scheme is presented, to realize the decoupling measurement of the transverse light-shift introduced by the whole co-magnetometer cell, and cancel it out with the non-ideal linear polarization of the probe laser. Eventually, the DOCP regulation scheme suggested in this paper achieves more than a 67% suppression ratio in transverse light-shift, and the short- and long-term performance of SERF co-magnetometer are improved due to the reduction of the coupling effect between the probe laser power and transverse field. Moreover, the measurement, decoupling and suppression methods provided in this paper also have the potential to be applied to other atomic sensors, such as the SERF magnetometers and nuclear spin co-magnetometers.

Optics Express•Apr 8, 2022•32 citations

High sensitivity detuned single-light-source orthogonal pump-probe SERF atomic magnetometer

Yuhao Wang, Ying Liu, Ziqian Yue +4 more

Optics and Lasers in Engineering•Feb 10, 2025•1 citation

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang +2 more

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

IEEE Sensors Journal•Jan 7, 2025•2 citations
The transverse light-shift can induce non-negligible polarization error in the output signal of spin-exchange relaxation-free (SERF) co-magnetometer. In this paper, a novel method for rapid measurement of transverse light-shift based on the error of steady-state response of co-magnetometer is proposed firstly, then the sources of transverse light-shift in a compact SERF co-magnetometer is modeled and analyzed from three aspects: the non-ideal linear polarization of probe laser, the circular dichroism of the atomic spin ensembles, and the stress-induced birefringence effect of the cell wall. Furthermore, the decoupling and suppression methods of transverse light-shift based on a degree of circular polarization (DOCP) regulation scheme is presented, to realize the decoupling measurement of the transverse light-shift introduced by the whole co-magnetometer cell, and cancel it out with the non-ideal linear polarization of the probe laser. Eventually, the DOCP regulation scheme suggested in this paper achieves more than a 67% suppression ratio in transverse light-shift, and the short- and long-term performance of SERF co-magnetometer are improved due to the reduction of the coupling effect between the probe laser power and transverse field. Moreover, the measurement, decoupling and suppression methods provided in this paper also have the potential to be applied to other atomic sensors, such as the SERF magnetometers and nuclear spin co-magnetometers.
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.