Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics & Laser Technology

A coherent population trapping magnetometer using a phase-delayed differential detection method

Pengcheng Du, Jiahao Yuan, Feifan Yang, Xianyang Huo, Jin Li

Published Apr 30, 2024• 6 citations
Publisher
DOI
10.1016/j.optlastec.2024.111078

Related papers

The Measurement of Simulative Weak Magnetic Field with a Cesium Magnetometer Based on Coherent Population Trapping

温馨 Wen Xin, 刘智 Liu Zhi, 王杰英 WANG Jie-ying +3 more

Acta Sinica Quantum Optica•Jan 1, 2013•0 citations

Coherent Population Trapping - Ein Quanteninterferenzeffekt als Basis optischer Magnetometer

Roland Lammegger

•Jan 1, 2006•4 citations

Simultaneous improvement of the sensitivity and resolution of CPT magnetometers based on phase delay and differential method

Jiahao Yuan, Pengcheng Du, Feifan Yang +2 more

We report a method to enhance the sensitivity of coherent population trapping (CPT) magnetometers using a combination of left-handed and right-handed circularly polarized light phase-delay detection and a differential detection scheme. The approach can achieve a four third-fold enhancement of the CPT dispersion signal slope and a three-fold reduction in noises. The proposed method experimentally exhibits a four third-fold magnetic field resolution enhancement in CPT open-loop measurements, and the differential method could achieve a sensitivity of 1 pT/Hz at 10 Hz and a sensitivity of 0.4 pT/Hz at 50–100 Hz in the CPT closed-loop measurement, which is a four-fold sensitivity enhancement compared to the single-transmitted CPT magnetometer.

Optics Letters•Jun 6, 2024•9 citations

Differentially detected coherent population trapping resonances excited by orthogonally polarized laser fields

M. Rosenbluh, Vishal Shah, Svenja A. Knappe +1 more

We demonstrate the excitation and low-noise differential detection of a coherent population trapping (CPT) resonance with two modulated optical fields with orthogonal circular polarizations. When a microwave phase delay of lambda/4 is introduced in the optical path of one of the fields, the difference in the power transmitted through the cell in each polarization shows a narrow, dispersive resonance. The differential detection allows a high degree of suppression of laser-induced noise and will enable nearly shot-noise-limited operation of atomic frequency references and magnetometers based on CPT.

Optics Express•Jan 1, 2006•38 citations

Phase dependent Coherent Population Trapping

Wolfgang Maichen, Rainer Gaggl, Eugeny Korsunsky +1 more

•Jan 1, 1995•0 citations

Phase dependent and transient coherent population trapping

Wolfgang Maichen, Rainer Gaggl, Ferruccio Renzoni +4 more

•Jan 1, 1996•0 citations
We report a method to enhance the sensitivity of coherent population trapping (CPT) magnetometers using a combination of left-handed and right-handed circularly polarized light phase-delay detection and a differential detection scheme. The approach can achieve a four third-fold enhancement of the CPT dispersion signal slope and a three-fold reduction in noises. The proposed method experimentally exhibits a four third-fold magnetic field resolution enhancement in CPT open-loop measurements, and the differential method could achieve a sensitivity of 1 pT/Hz at 10 Hz and a sensitivity of 0.4 pT/Hz at 50–100 Hz in the CPT closed-loop measurement, which is a four-fold sensitivity enhancement compared to the single-transmitted CPT magnetometer.
We demonstrate the excitation and low-noise differential detection of a coherent population trapping (CPT) resonance with two modulated optical fields with orthogonal circular polarizations. When a microwave phase delay of lambda/4 is introduced in the optical path of one of the fields, the difference in the power transmitted through the cell in each polarization shows a narrow, dispersive resonance. The differential detection allows a high degree of suppression of laser-induced noise and will enable nearly shot-noise-limited operation of atomic frequency references and magnetometers based on CPT.