Optics Letters
Simultaneous improvement of the sensitivity and resolution of CPT magnetometers based on phase delay and differential method
Jiahao Yuan, Pengcheng Du, Feifan Yang, Wei Quan, Li Jin
Abstract
We report a method to enhance the sensitivity of coherent population trapping (CPT) magnetometers using a combination of left-handed and right-handed circularly polarized light phase-delay detection and a differential detection scheme. The approach can achieve a four third-fold enhancement of the CPT dispersion signal slope and a three-fold reduction in noises. The proposed method experimentally exhibits a four third-fold magnetic field resolution enhancement in CPT open-loop measurements, and the differential method could achieve a sensitivity of 1 pT/Hz at 10 Hz and a sensitivity of 0.4 pT/Hz at 50–100 Hz in the CPT closed-loop measurement, which is a four-fold sensitivity enhancement compared to the single-transmitted CPT magnetometer.