Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Coherent population trapping magnetometer by differential detecting magneto–optic rotation effect

Fan Zhang, Yuan Tian, Yi Zhang, Sihong Gu

Published Aug 30, 2016• 12 citations
Publisher

Abstract

A pocket coherent population trapping (CPT) atomic magnetometer scheme that uses a vertical cavity surface emitting laser as a light source is proposed and experimentally investigated. Using the differential detecting magneto–optic rotation effect, a CPT spectrum with the background canceled and a high signal-to-noise ratio is obtained. The experimental results reveal that the sensitivity of the proposed scheme can be improved by half an order, and the ability to detect weak magnetic fields is extended one-fold. Therefore, the proposed scheme is suited to realize a pocket-size CPT magnetometer.

DOI
10.1088/1674-1056/25/9/094206

Related papers

Noise suppression in coherent population-trapping atomic clock by differential magneto-optic rotation detection

Bozhong Tan, Yuan Tian, Huifang Lin +2 more

We propose and investigate a scheme for differential detection of the magneto-optic rotation (MOR) effect, where a linearly polarized bichromatic laser field is coherent population-trapping (CPT)-resonant with alkali atoms, and discuss the application of this effect to CPT-based atomic clocks. The results of our study indicate that laser noise in a vertical cavity surface-emitting laser-based CPT atomic clock can be effectively suppressed by the proposed scheme. The proposed scheme promises to realize a packaged MOR-CPT atomic clock that has significantly better frequency stability coupled with similar power consumption, volume, and cost when compared with currently available packaged CPT atomic clocks.

Optics Letters•Jul 30, 2015•31 citations

Differential detection scheme for compact CPT atomic clocks

Huifang Lin, Yuan Tian, Bozhong Tan +1 more

A scheme is investigated for a coherent population trapping (CPT) atomic clock, wherein the polarization of a beam produced by a vertical-cavity surface-emitting laser is converted to an elliptically polarized beam that interacts with alkali atoms, where the CPT signal is extracted by differentially detecting the magneto-optically rotated light within the transmitted beam. The scheme eliminates the spin-polarized trap state of the atoms and the unwanted background signal, and suppresses in the CPT signal the noise converted from the laser noise. This result reveals the promise of this scheme for realizing a compact CPT atomic clock possessing a significantly improved frequency stability compared to current compact CPT atomic clock devices, coupled with similar power consumption, volume, and cost therewith.

Europhysics Letters (EPL)•Jul 1, 2017•11 citations

Magneto-optic rotation detection scheme for miniaturized coherent population trapping atomic clock

Suping Qu, Yi Yin, De-Huan Cai +1 more

In order to suppress the effects of carrier and high-order sidebands on the coherent population trapping (CPT) signal, a scheme of interaction between an elliptically polarized beam and alkali atoms using the magneto-optic rotation detection is examined. By canceling the spin-polarized dark state in the CPT state preparation, a CPT resonance signal with a contrast of 32.5% is obtained. Our scheme requires minor modifications of the optical path in the prevalent scheme, and the short-term frequency stability of our scheme is five times better than that of the prevalent scheme, making it ideal for miniaturized CPT atomic clock applications.

Applied Optics•Dec 10, 2019•2 citations

High contrast atomic magnetometer based on coherent population trapping

Ailin Yang, Guoqing Yang, Yunfei Xu +1 more

We present an experimental and theoretical investigation of the coherent population trapping (CPT) resonance excited on the D1 line of 87 Rb atoms by bichromatic linearly polarized laser light. The experimental results show that a lin ‖ lin transition scheme is a promising alternative to the conventional circular—circular transition scheme for an atomic magnetometer. Compared with the circular light transition scheme, linear light accounts for high-contrast transmission resonances, which makes this excitation scheme promising for high-sensitivity magnetometers. We also use linear light and circular light to detect changes of a standard magnetic field, separately.

Chinese Physics B•Feb 1, 2014•12 citations

Simultaneous improvement of the sensitivity and resolution of CPT magnetometers based on phase delay and differential method

Jiahao Yuan, Pengcheng Du, Feifan Yang +2 more

We report a method to enhance the sensitivity of coherent population trapping (CPT) magnetometers using a combination of left-handed and right-handed circularly polarized light phase-delay detection and a differential detection scheme. The approach can achieve a four third-fold enhancement of the CPT dispersion signal slope and a three-fold reduction in noises. The proposed method experimentally exhibits a four third-fold magnetic field resolution enhancement in CPT open-loop measurements, and the differential method could achieve a sensitivity of 1 pT/Hz at 10 Hz and a sensitivity of 0.4 pT/Hz at 50–100 Hz in the CPT closed-loop measurement, which is a four-fold sensitivity enhancement compared to the single-transmitted CPT magnetometer.

Optics Letters•Jun 6, 2024•8 citations

All optical automated magnetic field monitoring based on coherent population trapping produced by a frequency-modulated diode laser

Jacopo Belfi, G. Bevilacqua, V. Biancalana +2 more

A fully automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) effect produced by a multi-frequency excitation. It has an all optical sensor connected only by an optical fiber to the laser head. This allows truly remote sensing and minimization of the field perturbation. The CPT resonance is observed when a frequency comb, generated by a diode laser current modulation, excites a sample of Cs atoms confined in a cell with 2 Torr of buffer gas. In differential sensor configuration, allowing for common-mode noise cancellation, the sensitivity of 45pT/square root of Hz is obtained.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 2, 2007•0 citations
A pocket coherent population trapping (CPT) atomic magnetometer scheme that uses a vertical cavity surface emitting laser as a light source is proposed and experimentally investigated. Using the differential detecting magneto–optic rotation effect, a CPT spectrum with the background canceled and a high signal-to-noise ratio is obtained. The experimental results reveal that the sensitivity of the proposed scheme can be improved by half an order, and the ability to detect weak magnetic fields is extended one-fold. Therefore, the proposed scheme is suited to realize a pocket-size CPT magnetometer.
We propose and investigate a scheme for differential detection of the magneto-optic rotation (MOR) effect, where a linearly polarized bichromatic laser field is coherent population-trapping (CPT)-resonant with alkali atoms, and discuss the application of this effect to CPT-based atomic clocks. The results of our study indicate that laser noise in a vertical cavity surface-emitting laser-based CPT atomic clock can be effectively suppressed by the proposed scheme. The proposed scheme promises to realize a packaged MOR-CPT atomic clock that has significantly better frequency stability coupled with similar power consumption, volume, and cost when compared with currently available packaged CPT atomic clocks.
A scheme is investigated for a coherent population trapping (CPT) atomic clock, wherein the polarization of a beam produced by a vertical-cavity surface-emitting laser is converted to an elliptically polarized beam that interacts with alkali atoms, where the CPT signal is extracted by differentially detecting the magneto-optically rotated light within the transmitted beam. The scheme eliminates the spin-polarized trap state of the atoms and the unwanted background signal, and suppresses in the CPT signal the noise converted from the laser noise. This result reveals the promise of this scheme for realizing a compact CPT atomic clock possessing a significantly improved frequency stability compared to current compact CPT atomic clock devices, coupled with similar power consumption, volume, and cost therewith.
In order to suppress the effects of carrier and high-order sidebands on the coherent population trapping (CPT) signal, a scheme of interaction between an elliptically polarized beam and alkali atoms using the magneto-optic rotation detection is examined. By canceling the spin-polarized dark state in the CPT state preparation, a CPT resonance signal with a contrast of 32.5% is obtained. Our scheme requires minor modifications of the optical path in the prevalent scheme, and the short-term frequency stability of our scheme is five times better than that of the prevalent scheme, making it ideal for miniaturized CPT atomic clock applications.
We present an experimental and theoretical investigation of the coherent population trapping (CPT) resonance excited on the D1 line of 87 Rb atoms by bichromatic linearly polarized laser light. The experimental results show that a lin ‖ lin transition scheme is a promising alternative to the conventional circular—circular transition scheme for an atomic magnetometer. Compared with the circular light transition scheme, linear light accounts for high-contrast transmission resonances, which makes this excitation scheme promising for high-sensitivity magnetometers. We also use linear light and circular light to detect changes of a standard magnetic field, separately.
We report a method to enhance the sensitivity of coherent population trapping (CPT) magnetometers using a combination of left-handed and right-handed circularly polarized light phase-delay detection and a differential detection scheme. The approach can achieve a four third-fold enhancement of the CPT dispersion signal slope and a three-fold reduction in noises. The proposed method experimentally exhibits a four third-fold magnetic field resolution enhancement in CPT open-loop measurements, and the differential method could achieve a sensitivity of 1 pT/Hz at 10 Hz and a sensitivity of 0.4 pT/Hz at 50–100 Hz in the CPT closed-loop measurement, which is a four-fold sensitivity enhancement compared to the single-transmitted CPT magnetometer.
A fully automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) effect produced by a multi-frequency excitation. It has an all optical sensor connected only by an optical fiber to the laser head. This allows truly remote sensing and minimization of the field perturbation. The CPT resonance is observed when a frequency comb, generated by a diode laser current modulation, excites a sample of Cs atoms confined in a cell with 2 Torr of buffer gas. In differential sensor configuration, allowing for common-mode noise cancellation, the sensitivity of 45pT/square root of Hz is obtained.