Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Effects of system parameters on a single-beam synthetic gradiometer with a dual-cell structure

Zinan Wu, Jialong Zhang, Wei Chen, Zhonghua Ou, Huimin Yue, Chunyue Cheng, Yong Liu

Published Apr 18, 2024• 8 citations
Publisher

Abstract

We report a single-beam synthetic gradiometer operated in the spin-exchange-relaxation free (SERF) regime, using the structure of two separate atomic vapor cells spaced 2 cm apart. To improve the capability of the gradiometer in suppressing the common-mode magnetic field noise, we are aiming at investigating the effects of the system parameters on the gradiometer common-mode rejection ratio (CMRR). The mathematical expression for the relationship between the gradiometer CMRR and the two variables including the linewidth ratio and the pumping factor ratio is constructed for the first time, to our knowledge. This means that the CMRR can be optimized by controlling the linewidth and the pumping factor, which is easy to implement in the operation process. As a result, a CMRR of 246 is achieved and a gradiometer sensitivity of 4.5 fT/cm/Hz 1/2 is also measured. This method provides a theoretical and experimental basis for the automated operation of gradiometers, and the gradiometer system performance can be tuned to a desired state by simply controlling the linewidth and the incident light intensity.

DOI
10.1364/ol.518697

Related papers

Spin-exchange relaxation-free magnetic gradiometer with dual-beam and closed-loop Faraday modulation

Jiancheng Fang, Shuangai Wan, Jie Qin +2 more

Spin-exchange relaxation-free (SERF) atomic magnetometers usually adopt Faraday modulation to achieve better performance but suffer from laser intensity noise, thermal noise generated by the Faraday modulator, and nonmagnetic technical noise. These noises limit the sensitivity of the SERF magnetometer. We demonstrate a SERF magnetic gradiometer with dual-beam and closed-loop Faraday modulation. Operating in the SERF regime, the gradiometer utilizes an additional Faraday modulator rotation feedback to suppress probe laser intensity noise and thermal noise associated with the Faraday modulator, and it simultaneously uses dual-beam difference to cancel common-mode nonmagnetic technical noises. A gradient sensitivity of 14 fT/Hz1/2 per 1 cm gradiometer base length was achieved using Cs atoms.

Journal of the Optical Society of America B•Feb 12, 2014•24 citations

Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer

Yaxiang Wang, Tao Shi, Weiyong Zhou +5 more

In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm3.

Optics Express•Jun 7, 2022•14 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•62 citations

Single-beam highly sensitive magnetic field gradiometer based on the atomic spin-exchange relaxation-free effect

Yang Li, Yuxuan Ren, Huihui Zhai +3 more

This paper presents a single-beam atomic magnetic field measurement gradiometer, which is a highly sensitive magnetic field gradient measuring instrument based on the atom spin-exchange relaxation-free (SERF) effect. The reflective detection optical path structure is adopted. The spin precession signals of an atom under incident and reflected light are different. There is also a difference in the corresponding magnetic field distribution. The final measurement of magnetic field gradients is conducted based on the different magnetic field distributions. The single-beam high-sensitive magnetic field gradiometers based on the atomic SERF effect are more sensitive than conventional two-probe magnetic field gradiometers or two-beam magnetic field gradiometers. The gradiometers are not affected by a difference in the detected optical power in the single-beam detection light measurements. The reflector uses an angular cone prism for two-dimensional magnetic field gradient measurements and is simple to construct. The single-beam highly sensitive magnetic field gradient measurement instrument based on the atomic SERF effect has a reflective detection optical path structure. It uses a quarter-wave plate to achieve the initial signal phase elimination of both incident and reflected signal and an angular cone prism as a reflector to achieve two-dimensional measurement.

Applied Optics•Dec 6, 2021•4 citations

The Characterization of Atomic Vapor Cells for High-Sensitivity Magnetic Field Measurements in SERF Regime

Murat Salim Karabinaoğlu, Berfin Muhlise Caklı, Mehmet Hüseyin Sevim

Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.

IEEE Sensors Letters•Feb 24, 2025•5 citations

A microfabricated optically-pumped magnetic gradiometer

D. Sheng, Abigail R. Perry, Sean Krzyzewski +3 more

We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.

arXiv:1701.03236•Applied Physics Letters•Jan 16, 2017•179 citations
We report a single-beam synthetic gradiometer operated in the spin-exchange-relaxation free (SERF) regime, using the structure of two separate atomic vapor cells spaced 2 cm apart. To improve the capability of the gradiometer in suppressing the common-mode magnetic field noise, we are aiming at investigating the effects of the system parameters on the gradiometer common-mode rejection ratio (CMRR). The mathematical expression for the relationship between the gradiometer CMRR and the two variables including the linewidth ratio and the pumping factor ratio is constructed for the first time, to our knowledge. This means that the CMRR can be optimized by controlling the linewidth and the pumping factor, which is easy to implement in the operation process. As a result, a CMRR of 246 is achieved and a gradiometer sensitivity of 4.5 fT/cm/Hz 1/2 is also measured. This method provides a theoretical and experimental basis for the automated operation of gradiometers, and the gradiometer system performance can be tuned to a desired state by simply controlling the linewidth and the incident light intensity.
Spin-exchange relaxation-free (SERF) atomic magnetometers usually adopt Faraday modulation to achieve better performance but suffer from laser intensity noise, thermal noise generated by the Faraday modulator, and nonmagnetic technical noise. These noises limit the sensitivity of the SERF magnetometer. We demonstrate a SERF magnetic gradiometer with dual-beam and closed-loop Faraday modulation. Operating in the SERF regime, the gradiometer utilizes an additional Faraday modulator rotation feedback to suppress probe laser intensity noise and thermal noise associated with the Faraday modulator, and it simultaneously uses dual-beam difference to cancel common-mode nonmagnetic technical noises. A gradient sensitivity of 14 fT/Hz1/2 per 1 cm gradiometer base length was achieved using Cs atoms.
In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm3.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
This paper presents a single-beam atomic magnetic field measurement gradiometer, which is a highly sensitive magnetic field gradient measuring instrument based on the atom spin-exchange relaxation-free (SERF) effect. The reflective detection optical path structure is adopted. The spin precession signals of an atom under incident and reflected light are different. There is also a difference in the corresponding magnetic field distribution. The final measurement of magnetic field gradients is conducted based on the different magnetic field distributions. The single-beam high-sensitive magnetic field gradiometers based on the atomic SERF effect are more sensitive than conventional two-probe magnetic field gradiometers or two-beam magnetic field gradiometers. The gradiometers are not affected by a difference in the detected optical power in the single-beam detection light measurements. The reflector uses an angular cone prism for two-dimensional magnetic field gradient measurements and is simple to construct. The single-beam highly sensitive magnetic field gradient measurement instrument based on the atomic SERF effect has a reflective detection optical path structure. It uses a quarter-wave plate to achieve the initial signal phase elimination of both incident and reflected signal and an angular cone prism as a reflector to achieve two-dimensional measurement.
Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.