Applied Physics Letters

Operation of a Ramsey-CPT microcell atomic clock with driving current-based power modulation of a VCSEL

C. M. Rivera-Aguilar, Martin Callejo, Andrei Mursa, Clément Carlé, Rémy Vicarini, Moustafa Abdel Hafiz, Jean‐Michel Friedt, Nicolas Passilly, Rodolphe Boudot

Published Mar 11, 2024• 9 citations
Publisher

Abstract

We report on the operation of a coherent population trapping (CPT) microcell atomic clock using a pulsed Ramsey-like interrogation. The Ramsey-CPT sequence, defined by two-step optical pulses separated by a free-evolution dark time, is produced by switching on and off the output power of a low-power vertical-cavity surface-emitting laser, through direct modulation of its driving current. High-contrast and narrow Ramsey-CPT fringes are detected without the use of any external optical modulator stage. We demonstrate closed-loop operation of the clock based on high-speed digital signal processing implemented in a field programmable gate array board. The clock's short-term fractional frequency stability is 1.3 × 10−10τ−1/2 until 2000 s. A power light-shift coefficient of 8 × 10−11/μW, in relative value, is obtained for a dark time of 150 μs. This value is about ten times lower than in the continuous regime. These results show the feasibility of fully integrated atomic clocks based on Ramsey spectroscopy, which could provide enhanced long-term stability.

DOI
10.1063/5.0196975

Related papers

Microcell atomic clock using laser current-actuated power modulation with 10−12 range stability at 1 day

C. M. Rivera-Aguilar, Andrei Mursa, Clément Carlé +5 more

We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a single FPGA-based digital electronics board. A key aspect of proper clock operation was the implementation of a real-time tracking of the atomic signal detection window. The clock frequency dependence on laser power, microwave power, laser frequency, and timing of the detection window has been measured, obtaining sensitivity coefficients lower than those obtained with Ramsey-CPT spectroscopy. The Allan deviation of the SABR-CPT clock, based on a microfabricated cell with low-permeation glass windows, is 8 × 10 −10 at 1 s and averages down in the 10 −12 range at 1 day. These results might stimulate the development of chip-scale atomic clocks using Ramsey-based sequences, with reduced light-shift sensitivity, and enhanced long-term stability performances.

Scientific Reports•Oct 15, 2025•1 citation

Microcell CPT atomic clock using laser current-actuated power modulation with 10$^{-12}$ range stability at 1 day

C. M. Rivera-Aguilar, Andrei Mursa, Clément Carlé +5 more

We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a single FPGA-based digital electronics board. A key aspect of proper clock operation was the implementation of a real-time tracking of the atomic signal detection window. The clock frequency dependence on laser power, microwave power, laser frequency, and timing of the detection window has been measured, obtaining sensitivity coefficients lower than those obtained with Ramsey-CPT spectroscopy. The Allan deviation of the SABR-CPT clock, based on a microfabricated cell with low-permeation glass windows, is 1.1~$\times$~10$^{-9}$ at 1~s and averages down to the low 10$^{-12}$ range at 1 day integration time. These results pave the way towards the development of Ramsey-CPT chip-scale atomic clocks with enhanced timekeeping performances.

arXiv:2503.01681•Mar 3, 2025•0 citations

Exploring the Use of Ramsey-CPT Spectroscopy for a Microcell-Based Atomic Clock

Clément Carlé, Michael Petersen, Nicolas Passilly +3 more

We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and$450~\mu \text{s}$, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of$450~\mu \text{s}$, a clock fractional frequency stability of$3.8 \times 10^{-12}$at 104s is obtained, in comparison with the level of$8\times 10^{-11}$obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jun 2, 2021•17 citations

A high-performance Raman-Ramsey Cs vapor cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, Peter Yun +3 more

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.

arXiv:1703.04720•Journal of Applied Physics•Mar 10, 2017•86 citations

Protocol for Light-Shift Compensation in a Continuous-Wave Microcell Atomic Clock

Moustafa Abdel Hafiz, Rémy Vicarini, Nicolas Passilly +7 more

Light shifts are known to be an important limitation to the mid- and long-term fractional frequency stability of different types of atomic clocks. In this article, we demonstrate the experimental implementation of an anti-light-shift interrogation protocol onto a continuous-wave (cw) microcell atomic clock based on coherent population trapping (CPT). The method, inspired by the autobalanced Ramsey spectroscopy technique demonstrated in pulsed atomic clocks, consists in the extraction of atomic based information from two successive light-shifted clock frequencies obtained at two different laser-power values. Two error signals, computed from the linear combination of signals acquired along a symmetric sequence, are managed in a dual-loop configuration to generate a clock frequency free from light shift. Using this method, the sensitivity of the clock frequency to both laser-power and microwave-power variations can be reduced by more than an order of magnitude compared to normal operation. In the present experiment, the consideration of the nonlinear light-shift dependence allows enhancement of the light-shift mitigation. The implemented technique allows an improvement of the clock Allan deviation for time scales higher than 1000 s. This method can be applied in various kinds of atomic clocks such as CPT-based atomic clocks, double-resonance $\mathrm{Rb}$ clocks, or cell-stabilized lasers.

arXiv:2005.05096•Physical Review Applied•Sep 8, 2020•38 citations

A CPT-based Cs vapor cell atomic clock with a short-term fractional frequency stability of 3 x 10-13τ-1/2

Moustafa Abdel Hafiz, Xiaochi Liu, Stéphane Guérandel +2 more

This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.

Journal of Physics Conference Series•Jun 1, 2016•6 citations
We report on the operation of a coherent population trapping (CPT) microcell atomic clock using a pulsed Ramsey-like interrogation. The Ramsey-CPT sequence, defined by two-step optical pulses separated by a free-evolution dark time, is produced by switching on and off the output power of a low-power vertical-cavity surface-emitting laser, through direct modulation of its driving current. High-contrast and narrow Ramsey-CPT fringes are detected without the use of any external optical modulator stage. We demonstrate closed-loop operation of the clock based on high-speed digital signal processing implemented in a field programmable gate array board. The clock's short-term fractional frequency stability is 1.3 × 10−10τ−1/2 until 2000 s. A power light-shift coefficient of 8 × 10−11/μW, in relative value, is obtained for a dark time of 150 μs. This value is about ten times lower than in the continuous regime. These results show the feasibility of fully integrated atomic clocks based on Ramsey spectroscopy, which could provide enhanced long-term stability.
We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a single FPGA-based digital electronics board. A key aspect of proper clock operation was the implementation of a real-time tracking of the atomic signal detection window. The clock frequency dependence on laser power, microwave power, laser frequency, and timing of the detection window has been measured, obtaining sensitivity coefficients lower than those obtained with Ramsey-CPT spectroscopy. The Allan deviation of the SABR-CPT clock, based on a microfabricated cell with low-permeation glass windows, is 8 × 10 −10 at 1 s and averages down in the 10 −12 range at 1 day. These results might stimulate the development of chip-scale atomic clocks using Ramsey-based sequences, with reduced light-shift sensitivity, and enhanced long-term stability performances.
Microcell CPT atomic clock using laser current-actuated power modulation with 10−12^{-12}−12 range stability at 1 day
We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a single FPGA-based digital electronics board. A key aspect of proper clock operation was the implementation of a real-time tracking of the atomic signal detection window. The clock frequency dependence on laser power, microwave power, laser frequency, and timing of the detection window has been measured, obtaining sensitivity coefficients lower than those obtained with Ramsey-CPT spectroscopy. The Allan deviation of the SABR-CPT clock, based on a microfabricated cell with low-permeation glass windows, is 1.1~×\times×~10−9^{-9}−9 at 1~s and averages down to the low 10−12^{-12}−12 range at 1 day integration time. These results pave the way towards the development of Ramsey-CPT chip-scale atomic clocks with enhanced timekeeping performances.
We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and450 μs450~\mu \text{s}450 μs, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of450 μs450~\mu \text{s}450 μs, a clock fractional frequency stability of3.8×10−123.8 \times 10^{-12}3.8×10−12at 104s is obtained, in comparison with the level of8×10−118\times 10^{-11}8×10−11obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
Light shifts are known to be an important limitation to the mid- and long-term fractional frequency stability of different types of atomic clocks. In this article, we demonstrate the experimental implementation of an anti-light-shift interrogation protocol onto a continuous-wave (cw) microcell atomic clock based on coherent population trapping (CPT). The method, inspired by the autobalanced Ramsey spectroscopy technique demonstrated in pulsed atomic clocks, consists in the extraction of atomic based information from two successive light-shifted clock frequencies obtained at two different laser-power values. Two error signals, computed from the linear combination of signals acquired along a symmetric sequence, are managed in a dual-loop configuration to generate a clock frequency free from light shift. Using this method, the sensitivity of the clock frequency to both laser-power and microwave-power variations can be reduced by more than an order of magnitude compared to normal operation. In the present experiment, the consideration of the nonlinear light-shift dependence allows enhancement of the light-shift mitigation. The implemented technique allows an improvement of the clock Allan deviation for time scales higher than 1000 s. This method can be applied in various kinds of atomic clocks such as CPT-based atomic clocks, double-resonance Rb\mathrm{Rb}Rb clocks, or cell-stabilized lasers.
This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.