Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2005.05096 · Physical Review Applied

Protocol for Light-Shift Compensation in a Continuous-Wave Microcell Atomic Clock

Moustafa Abdel Hafiz, Rémy Vicarini, Nicolas Passilly, Claudio Eligio Calosso, Vincent N. Maurice, J.W. Pollock, A.V. Taichenachev, V.I. Yudin, J. Kitching, Rodolphe Boudot

Published Sep 8, 2020• 38 citations
arXivHTMLPDF

Abstract

Light shifts are known to be an important limitation to the mid- and long-term fractional frequency stability of different types of atomic clocks. In this article, we demonstrate the experimental implementation of an anti-light-shift interrogation protocol onto a continuous-wave (cw) microcell atomic clock based on coherent population trapping (CPT). The method, inspired by the autobalanced Ramsey spectroscopy technique demonstrated in pulsed atomic clocks, consists in the extraction of atomic based information from two successive light-shifted clock frequencies obtained at two different laser-power values. Two error signals, computed from the linear combination of signals acquired along a symmetric sequence, are managed in a dual-loop configuration to generate a clock frequency free from light shift. Using this method, the sensitivity of the clock frequency to both laser-power and microwave-power variations can be reduced by more than an order of magnitude compared to normal operation. In the present experiment, the consideration of the nonlinear light-shift dependence allows enhancement of the light-shift mitigation. The implemented technique allows an improvement of the clock Allan deviation for time scales higher than 1000 s. This method can be applied in various kinds of atomic clocks such as CPT-based atomic clocks, double-resonance $\mathrm{Rb}$ clocks, or cell-stabilized lasers.

DOI
10.1103/physrevapplied.14.034015

Related papers

Light-shift mitigation in a microcell-based atomic clock with symmetric auto-balanced Ramsey spectroscopy

Moustafa Abdel Hafiz, Clément Carlé, Nicolas Passilly +3 more

The mid-term fractional frequency stability of miniaturized atomic clocks can be limited by light-shift effects. In this Letter, we demonstrate the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence in a microcell-based atomic clock based on coherent population trapping. Using this advanced protocol, the sensitivity of the clock frequency to laser power, microwave power, and laser frequency variations is reduced, at least by one order of magnitude, in comparison with continuous-wave or Ramsey interrogation schemes. Light-shift mitigation obtained with the SABR sequence benefits greatly to the clock Allan deviation for integration times between 102 and 105 s. These results demonstrate that such interrogation techniques are of interest to enhance the timekeeping performance of chip-scale atomic clocks.

arXiv:2112.07492•Applied Physics Letters•Feb 7, 2022•17 citations

Exploring the Use of Ramsey-CPT Spectroscopy for a Microcell-Based Atomic Clock

Clément Carlé, Michael Petersen, Nicolas Passilly +3 more

We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and$450~\mu \text{s}$, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of$450~\mu \text{s}$, a clock fractional frequency stability of$3.8 \times 10^{-12}$at 104s is obtained, in comparison with the level of$8\times 10^{-11}$obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jun 2, 2021•17 citations

Reduction of light shifts in Ramsey spectroscopy with a combined error signal

M. Shuker, J. W. Pollock, Rodolphe Boudot +4 more

Light-induced frequency shifts can be a key limiting contribution to the mid- and long-term frequency instabilities in atomic clocks. In this letter, we demonstrate the experimental implementation of the combined error signal interrogation protocol to a cold-atom clock based on coherent population trapping (CPT) and Ramsey spectroscopy. The method uses a single error signal that results from the normalized combination of two error signals extracted from two Ramsey sequences of different dark periods. The single combined error signal is used to stabilize the atomic clock frequency. Compared to the standard Ramsey-CPT interrogation, this method reduces the clock frequency sensitivity to light-shift variations by more than one order of magnitude. This method can be applied in various kinds of Ramsey-based atomic clocks, sensors, and instruments.

arXiv:1903.00566•Applied Physics Letters•Apr 8, 2019•27 citations

Symmetric autobalanced Ramsey interrogation for high-performance coherent-population-trapping vapor-cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, M. Petersen +4 more

We report a high-performance pulsed coherent population trapping (CPT) Cs cell atomic clock using the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence. The latter method is found to reduce the light-power induced frequency shift by an order of magnitude compared to a previous experiment using a simple auto-balanced Ramsey interrogation. The contribution of this shift to the clock frequency stability is now rejected in the 10−16 range at 104 s averaging time. Additional tricks, including a compensation method to reduce the laser amplitude noise contribution and the generation of novel error signals for local oscillator frequency and phase correction, have been implemented using a FPGA-based digital electronics board in order to improve the clock short-term stability by a of factor 2. The Allan deviation of the SABR-CPT clock, extracted from a selected 3 × 104 s-long dataset, is 2 × 10−13 τ−1∕2 and averages down to the level of 2.5 × 10−15 at 104 s. These results are encouraging to stimulate the development of hot cell CPT-based clocks for industrial, scientific, and instrumentation applications.

Applied Physics Letters•Jun 11, 2018•72 citations

Reduction of light shifts in a cold-atom CPT clock

Maojie Li, Zhu Ma, Jiatao Wu +5 more

Abstract Light shifts induced during atom–light interactions significantly affect the medium- and long-term frequency stability of atomic clocks. Here, we employ composite laser pulse sequences to mitigate interrogation-induced light shifts in a cold-atom coherent-population-trapping clock. We obtain the anti-symmetry error signal via modulating the local oscillator phase in the free-evolution time of Ramsey interferometry. Utilizing this signal, we employ two feedback loops to simultaneously eliminate light shifts and stabilize the clock frequency using the auto-balanced Ramsey (ABR) spectroscopy scheme. Our experimental results demonstrate that this approach can reduce the clock frequency’s sensitivity to variations in light shifts by implementing four Ramsey sub-sequences. Furthermore, we show that the ABR spectroscopy scheme enhances the long-term frequency stability of the atomic clock when the averaging time τ > 5000 s.

Journal of Physics B Atomic Molecular and Optical Physics•Apr 23, 2024•3 citations

Pulsed-CPT Cs-Ne microcell atomic clock with frequency stability below 2 × 10 −12 at 10 5 s

Clément Carlé, Moustafa Abdel Hafiz, Shervin Keshavarzi +3 more

We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.

Optics Express•Feb 10, 2023•29 citations
Light shifts are known to be an important limitation to the mid- and long-term fractional frequency stability of different types of atomic clocks. In this article, we demonstrate the experimental implementation of an anti-light-shift interrogation protocol onto a continuous-wave (cw) microcell atomic clock based on coherent population trapping (CPT). The method, inspired by the autobalanced Ramsey spectroscopy technique demonstrated in pulsed atomic clocks, consists in the extraction of atomic based information from two successive light-shifted clock frequencies obtained at two different laser-power values. Two error signals, computed from the linear combination of signals acquired along a symmetric sequence, are managed in a dual-loop configuration to generate a clock frequency free from light shift. Using this method, the sensitivity of the clock frequency to both laser-power and microwave-power variations can be reduced by more than an order of magnitude compared to normal operation. In the present experiment, the consideration of the nonlinear light-shift dependence allows enhancement of the light-shift mitigation. The implemented technique allows an improvement of the clock Allan deviation for time scales higher than 1000 s. This method can be applied in various kinds of atomic clocks such as CPT-based atomic clocks, double-resonance Rb\mathrm{Rb}Rb clocks, or cell-stabilized lasers.
The mid-term fractional frequency stability of miniaturized atomic clocks can be limited by light-shift effects. In this Letter, we demonstrate the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence in a microcell-based atomic clock based on coherent population trapping. Using this advanced protocol, the sensitivity of the clock frequency to laser power, microwave power, and laser frequency variations is reduced, at least by one order of magnitude, in comparison with continuous-wave or Ramsey interrogation schemes. Light-shift mitigation obtained with the SABR sequence benefits greatly to the clock Allan deviation for integration times between 102 and 105 s. These results demonstrate that such interrogation techniques are of interest to enhance the timekeeping performance of chip-scale atomic clocks.
We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and450 μs450~\mu \text{s}450 μs, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of450 μs450~\mu \text{s}450 μs, a clock fractional frequency stability of3.8×10−123.8 \times 10^{-12}3.8×10−12at 104s is obtained, in comparison with the level of8×10−118\times 10^{-11}8×10−11obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.
Light-induced frequency shifts can be a key limiting contribution to the mid- and long-term frequency instabilities in atomic clocks. In this letter, we demonstrate the experimental implementation of the combined error signal interrogation protocol to a cold-atom clock based on coherent population trapping (CPT) and Ramsey spectroscopy. The method uses a single error signal that results from the normalized combination of two error signals extracted from two Ramsey sequences of different dark periods. The single combined error signal is used to stabilize the atomic clock frequency. Compared to the standard Ramsey-CPT interrogation, this method reduces the clock frequency sensitivity to light-shift variations by more than one order of magnitude. This method can be applied in various kinds of Ramsey-based atomic clocks, sensors, and instruments.
We report a high-performance pulsed coherent population trapping (CPT) Cs cell atomic clock using the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence. The latter method is found to reduce the light-power induced frequency shift by an order of magnitude compared to a previous experiment using a simple auto-balanced Ramsey interrogation. The contribution of this shift to the clock frequency stability is now rejected in the 10−16 range at 104 s averaging time. Additional tricks, including a compensation method to reduce the laser amplitude noise contribution and the generation of novel error signals for local oscillator frequency and phase correction, have been implemented using a FPGA-based digital electronics board in order to improve the clock short-term stability by a of factor 2. The Allan deviation of the SABR-CPT clock, extracted from a selected 3 × 104 s-long dataset, is 2 × 10−13 τ−1∕2 and averages down to the level of 2.5 × 10−15 at 104 s. These results are encouraging to stimulate the development of hot cell CPT-based clocks for industrial, scientific, and instrumentation applications.
Abstract Light shifts induced during atom–light interactions significantly affect the medium- and long-term frequency stability of atomic clocks. Here, we employ composite laser pulse sequences to mitigate interrogation-induced light shifts in a cold-atom coherent-population-trapping clock. We obtain the anti-symmetry error signal via modulating the local oscillator phase in the free-evolution time of Ramsey interferometry. Utilizing this signal, we employ two feedback loops to simultaneously eliminate light shifts and stabilize the clock frequency using the auto-balanced Ramsey (ABR) spectroscopy scheme. Our experimental results demonstrate that this approach can reduce the clock frequency’s sensitivity to variations in light shifts by implementing four Ramsey sub-sequences. Furthermore, we show that the ABR spectroscopy scheme enhances the long-term frequency stability of the atomic clock when the averaging time τ > 5000 s.
We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.