Chinese Physics B

Terahertz high-sensitivity SIS mixer based on Nb–AlN–NbN hybrid superconducting tunnel junctions

Bo-Liang 博梁 Liu 刘, Dong 冬 Liu 刘, Ming Yao, Jun-Da 骏达 Jin 金, Zheng 争 Wang 王, Jing 婧 Li 李, Sheng-Cai 生才 Shi 史, Artem M. Chekushkin, M. Yu. Fominsky, Lyudmila V. Filippenko, V. P. Koshelets

Published Feb 22, 2024• 5 citations
Publisher

Abstract

The terahertz band, a unique segment of the electromagnetic spectrum, is crucial for observing the cold, dark universe and plays a pivotal role in cutting-edge scientific research, including the study of cosmic environments that support life and imaging black holes. High-sensitivity superconductor–insulator–superconductor (SIS) mixers are essential detectors for terahertz astronomical telescopes and interferometric arrays. Compared to the commonly used classical Nb/AlO x /Nb superconducting tunnel junction, the Nb/AlN/NbN hybrid superconducting tunnel junction has a higher energy gap voltage and can achieve a higher critical current density. This makes it particularly promising for the development of ultra-wideband, high-sensitivity coherent detectors or mixers in various scientific research fields. In this paper, we present a superconducting SIS mixer based on Nb/AlN/NbN parallel-connected twin junctions (PCTJ), which has a bandwidth extending up to 490 GHz–720 GHz. The best achieved double-sideband (DSB) noise temperature (sensitivity) is below three times the quantum noise level.

DOI
10.1088/1674-1056/ad2bf7

Related papers

0.5-THz waveguide SIS mixers with NbN/AlN/NbN technology

Jing Li, Masanori Takeda, Zhen Wang +1 more

Heterodyne mixers based on superconducting SIS (superconductor-insulator-superconductor) tunnel junctions have been demonstrated to be the most sensitive coherent detectors at millimeter and submillimeter wavelengths. In fact, conventional superconducting SIS mixers with Nb/AlOx/Nb junction and Nb/SiO2/Nb tuning circuit have shown good performances with the noise temperature reaching as low as three times the quantum limit below 0.7THz, which is the gap frequency of Nb-based SIS junctions. However, due to the large loss in Nb thin-film superconducting microstrip lines, the noise performance of Nb SIS mixers deteriorates significantly above 0.7THz. With a gap frequency double that of Nb-based SIS junctions, NbN-based SIS junctions are of particular interest for the development of heterodyne mixers in the terahertz region. Considering the bandwidth and output power of local-oscillator (LO) signal sources are quite limited around 1THz, we firstly develop a waveguide NbN-based SIS mixer at 0.5THz. Three types of SIS junctions, i.e., long junction, parallel-connected tunnel junction (PCTJ) and distributed junction array (DJ) are investigated. They are all comprised of NbN-AlN-NbN tri-layer fabricated on an MgO substrate and have the same current density (Jc) of 10kA/cm2. In this paper, we describe their design, fabrication and preliminary experimental results.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 29, 2007•3 citations

Noise performance of a 200–280 GHz mixer with Nb-AlN-NbN superconducting tunnel junctions

Boliang Liu, Dong Liu, Ming Yao +6 more

Superconductor–insulator–superconductor (SIS) mixers remain the choice of heterodyne mixers for single-dish telescopes and interferometers at millimeter and submillimeter wavelengths. Compared with conventional Nb/AlOx/Nb superconducting tunnel junctions, Nb/AlN/NbN ones have larger gap voltage and may reach critical-current density beyond 10kA/cm2, which are both of particularly interest in developing broadband SIS mixers. Here we report on the design and measurement of an SIS mixer based on Nb/AlN/NbN parallel connected twin junctions (PCTJ) incorporating NbTiN/SiO2/Al microstrip circuit. The junctions have a gap voltage of 3.18mV and a critical-current density of 15kA/cm2. The measured receiver noise temperature reach 5hν/kB among 200-260GHz band, and the mixer’s fractional bandwidth is about 40% centered at 230GHz.

Infrared, Millimeter-Wave, and Terahertz Technologies•Dec 16, 2022•0 citations

0.5-THz waveguide SIS mixers with NbN/AlN/NbN technology - art. no. 684013

Jing Li, Takeda Masanon, Zhen Wang

Heterodyne mixers based on superconducting SIS (superconductor-insulator-superconductor) tunnel junctions have been demonstrated to be the most sensitive coherent detectors at millimeter and submillimeter wavelengths. In fact, conventional superconducting SIS mixers with Nb/AIO(x)/Nb junction and Nb/SiO2/Nb tuning circuit have shown good performances with the noise temperature reaching as low as three times the quantum limit below 0.7THz, which is the gap frequency of Nb-based SIS junctions. However, due to the large loss in Nb thin-film superconducting microstrip lines, the noise performance of Nb SIS mixers deteriorates significantly above 0.7THz. With a gap frequency double that of Nb-based SIS junctions, NbN-based SIS junctions are of particular interest for the development of heterodyne mixers in the terahertz region.

•Jan 1, 2008•0 citations

Three Quanta Sensitivity Superconductor–Insulator–Superconductor Mixer for the 0.78–0.95 THz Band

Takafumi Kojima, M. Kroug, Masanori Takeda +5 more

We have successfully demonstrated a low-noise 0.78–0.95-THz waveguide mixer based on Nb/AlO x /Nb superconductor–insulator–superconductor (SIS) junctions integrated with an NbTiN/SiO 2 /Al superconducting inverted microstrip. The mixer employs a twin-junction tuning circuit and an impedance transformer which are designed to achieve both low noise and wideband operation. Corrected for optical input losses in front of the mixer, the double-sideband (DSB) noise temperature is below 120 K (<3 hf / k B ) around the local oscillator (LO) frequency of 0.88 THz and at an operating temperature of 2 K. The results represent state-of-the-art performance for mixers in the terahertz frequency range.

Applied Physics Express•Oct 9, 2009•26 citations

Low-noise submillimeter-wave NbTiN superconducting tunnel junction mixers

Jonathan H. Kawamura, Jian Chen, David Miller +5 more

We have developed a low-noise 850 GHz superconductor–insulator–superconductor quasiparticle mixer with NbTiN thin-film microstrip tuning circuits and hybrid Nb/AlN/NbTiN tunnel junctions. The mixer uses a quasioptical configuration with a planar twin-slot antenna feeding a two-junction tuning circuit. At 798 GHz, we measured an uncorrected double-sideband receiver noise temperature of TRX=260 K at 4.2 K bath temperature. This mixer outperforms current Nb SIS mixers by a factor of nearly 2 near 800 GHz. The high-gap frequency and low loss at 800 GHz make NbTiN an attractive material with which to fabricate tuning circuits for SIS mixers. NbTiN mixers can potentially operate up to the gap frequency, 2Δ/h∼1.2 THz.

Applied Physics Letters•Dec 20, 1999•81 citations

Terahertz high-sensitivity superconducting detectors

Shi Sheng-Cai, Jing Li, Wen Zhang +1 more

The terahertz regime, as a last radio window, remains to be fully explored, and astronomical and atmospheric observations in this regime are scientifically important. Like other frequency regimes, developing high-sensitivity detectors (coherent and incoherent) is of particular significance for both ground-based and space-borne facilities. As the coherent detector of choice below 1.4 THz, superconductor-insulator-superconductor (SIS) heterodyne mixers have achieved as high a sensitivity as five times the quantum limit around 1.4 THz. It is, however, still a challenge to developing SIS mixers at frequencies beyond 1.4 THz with considerable transmission loss in superconducting circuits due to the Cooper-pair breaking by energetic photons and increased many difficulties in designing and fabricating. So far, superconducting hot electron bolometer (HEB) mixers have been the most sensitive heterodyne detectors at frequencies above 1.5 THz, and successfully used to detect molecular spectral lines up to 2.5 THz from ground-based and space telescopes. Although spiral-antenna coupled NbN HEB mixers show a good sensitivity in the whole THz frequency range, the directly measured spectral response with Fourier transform spectrometer falls quickly as frequency increases, especially above 3 THz. The terahertz band is also of particular importance to observe astronomical objects such as cosmic microwave background, early distant objects, cold objects and dusty objects. Aiming at such objects, we develop a terahertz imaging array system by combining advanced superconducting detectors such as transition edge sensor (TES) and microwave kinetic inductance detectors (MKIDs), thus the system has a frequency band centred at 350 m, an operational temperature of 0.3 K, and a sensitivity reaching background limit performance for ground-based applications. In addition, it is expected to have some breakthroughs in ultra-sensitive superconducting TES and MKID, low noise multi-channel readout and multiplexing, efficient terahertz-wave coupling technology, and large-scale array system integration. The developed terahertz imaging array system will serve as the next-generation instrument of Dome A 5 m terahertz telescope, conducting a 350 m-band legacy survey for studying the planets, stars, galaxies and cosmology. Besides the application in astronomy, the developed terahertz imaging array system can also be applied to some areas requiring rapid detection such as security, deep space exploration, and biomedical imaging. In this paper, we mainly introduce the superconducting detectors developed at Purple Mountain Observatory and those for international collaborative projects.

Acta Physica Sinica•Jan 1, 2015•8 citations
The terahertz band, a unique segment of the electromagnetic spectrum, is crucial for observing the cold, dark universe and plays a pivotal role in cutting-edge scientific research, including the study of cosmic environments that support life and imaging black holes. High-sensitivity superconductor–insulator–superconductor (SIS) mixers are essential detectors for terahertz astronomical telescopes and interferometric arrays. Compared to the commonly used classical Nb/AlO x /Nb superconducting tunnel junction, the Nb/AlN/NbN hybrid superconducting tunnel junction has a higher energy gap voltage and can achieve a higher critical current density. This makes it particularly promising for the development of ultra-wideband, high-sensitivity coherent detectors or mixers in various scientific research fields. In this paper, we present a superconducting SIS mixer based on Nb/AlN/NbN parallel-connected twin junctions (PCTJ), which has a bandwidth extending up to 490 GHz–720 GHz. The best achieved double-sideband (DSB) noise temperature (sensitivity) is below three times the quantum noise level.
Heterodyne mixers based on superconducting SIS (superconductor-insulator-superconductor) tunnel junctions have been demonstrated to be the most sensitive coherent detectors at millimeter and submillimeter wavelengths. In fact, conventional superconducting SIS mixers with Nb/AlOx/Nb junction and Nb/SiO2/Nb tuning circuit have shown good performances with the noise temperature reaching as low as three times the quantum limit below 0.7THz, which is the gap frequency of Nb-based SIS junctions. However, due to the large loss in Nb thin-film superconducting microstrip lines, the noise performance of Nb SIS mixers deteriorates significantly above 0.7THz. With a gap frequency double that of Nb-based SIS junctions, NbN-based SIS junctions are of particular interest for the development of heterodyne mixers in the terahertz region. Considering the bandwidth and output power of local-oscillator (LO) signal sources are quite limited around 1THz, we firstly develop a waveguide NbN-based SIS mixer at 0.5THz. Three types of SIS junctions, i.e., long junction, parallel-connected tunnel junction (PCTJ) and distributed junction array (DJ) are investigated. They are all comprised of NbN-AlN-NbN tri-layer fabricated on an MgO substrate and have the same current density (Jc) of 10kA/cm2. In this paper, we describe their design, fabrication and preliminary experimental results.
Superconductor–insulator–superconductor (SIS) mixers remain the choice of heterodyne mixers for single-dish telescopes and interferometers at millimeter and submillimeter wavelengths. Compared with conventional Nb/AlOx/Nb superconducting tunnel junctions, Nb/AlN/NbN ones have larger gap voltage and may reach critical-current density beyond 10kA/cm2, which are both of particularly interest in developing broadband SIS mixers. Here we report on the design and measurement of an SIS mixer based on Nb/AlN/NbN parallel connected twin junctions (PCTJ) incorporating NbTiN/SiO2/Al microstrip circuit. The junctions have a gap voltage of 3.18mV and a critical-current density of 15kA/cm2. The measured receiver noise temperature reach 5hν/kB among 200-260GHz band, and the mixer’s fractional bandwidth is about 40% centered at 230GHz.
Heterodyne mixers based on superconducting SIS (superconductor-insulator-superconductor) tunnel junctions have been demonstrated to be the most sensitive coherent detectors at millimeter and submillimeter wavelengths. In fact, conventional superconducting SIS mixers with Nb/AIO(x)/Nb junction and Nb/SiO2/Nb tuning circuit have shown good performances with the noise temperature reaching as low as three times the quantum limit below 0.7THz, which is the gap frequency of Nb-based SIS junctions. However, due to the large loss in Nb thin-film superconducting microstrip lines, the noise performance of Nb SIS mixers deteriorates significantly above 0.7THz. With a gap frequency double that of Nb-based SIS junctions, NbN-based SIS junctions are of particular interest for the development of heterodyne mixers in the terahertz region.
We have successfully demonstrated a low-noise 0.78–0.95-THz waveguide mixer based on Nb/AlO x /Nb superconductor–insulator–superconductor (SIS) junctions integrated with an NbTiN/SiO 2 /Al superconducting inverted microstrip. The mixer employs a twin-junction tuning circuit and an impedance transformer which are designed to achieve both low noise and wideband operation. Corrected for optical input losses in front of the mixer, the double-sideband (DSB) noise temperature is below 120 K (<3 hf / k B ) around the local oscillator (LO) frequency of 0.88 THz and at an operating temperature of 2 K. The results represent state-of-the-art performance for mixers in the terahertz frequency range.
We have developed a low-noise 850 GHz superconductor–insulator–superconductor quasiparticle mixer with NbTiN thin-film microstrip tuning circuits and hybrid Nb/AlN/NbTiN tunnel junctions. The mixer uses a quasioptical configuration with a planar twin-slot antenna feeding a two-junction tuning circuit. At 798 GHz, we measured an uncorrected double-sideband receiver noise temperature of TRX=260 K at 4.2 K bath temperature. This mixer outperforms current Nb SIS mixers by a factor of nearly 2 near 800 GHz. The high-gap frequency and low loss at 800 GHz make NbTiN an attractive material with which to fabricate tuning circuits for SIS mixers. NbTiN mixers can potentially operate up to the gap frequency, 2Δ/h∼1.2 THz.
The terahertz regime, as a last radio window, remains to be fully explored, and astronomical and atmospheric observations in this regime are scientifically important. Like other frequency regimes, developing high-sensitivity detectors (coherent and incoherent) is of particular significance for both ground-based and space-borne facilities. As the coherent detector of choice below 1.4 THz, superconductor-insulator-superconductor (SIS) heterodyne mixers have achieved as high a sensitivity as five times the quantum limit around 1.4 THz. It is, however, still a challenge to developing SIS mixers at frequencies beyond 1.4 THz with considerable transmission loss in superconducting circuits due to the Cooper-pair breaking by energetic photons and increased many difficulties in designing and fabricating. So far, superconducting hot electron bolometer (HEB) mixers have been the most sensitive heterodyne detectors at frequencies above 1.5 THz, and successfully used to detect molecular spectral lines up to 2.5 THz from ground-based and space telescopes. Although spiral-antenna coupled NbN HEB mixers show a good sensitivity in the whole THz frequency range, the directly measured spectral response with Fourier transform spectrometer falls quickly as frequency increases, especially above 3 THz. The terahertz band is also of particular importance to observe astronomical objects such as cosmic microwave background, early distant objects, cold objects and dusty objects. Aiming at such objects, we develop a terahertz imaging array system by combining advanced superconducting detectors such as transition edge sensor (TES) and microwave kinetic inductance detectors (MKIDs), thus the system has a frequency band centred at 350 m, an operational temperature of 0.3 K, and a sensitivity reaching background limit performance for ground-based applications. In addition, it is expected to have some breakthroughs in ultra-sensitive superconducting TES and MKID, low noise multi-channel readout and multiplexing, efficient terahertz-wave coupling technology, and large-scale array system integration. The developed terahertz imaging array system will serve as the next-generation instrument of Dome A 5 m terahertz telescope, conducting a 350 m-band legacy survey for studying the planets, stars, galaxies and cosmology. Besides the application in astronomy, the developed terahertz imaging array system can also be applied to some areas requiring rapid detection such as security, deep space exploration, and biomedical imaging. In this paper, we mainly introduce the superconducting detectors developed at Purple Mountain Observatory and those for international collaborative projects.