Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Japanese Journal of Applied Physics

Simultaneous observation of semi-continuous and Ramsey-coherent population trapping resonances using the Ramsey pulse sequence with drive current modulation

Masahiro Fukuoka, Shigeyoshi Goka

Published Dec 15, 2023• 4 citations
Publisher

Abstract

Abstract In this study, we proposed a method to observe the semi-cw excited coherent population trapping (SCW-CPT) and the Ramsey-CPT resonance during a Ramsey pulse sequence. By simultaneously observing the Ramsey-CPT and SCW-CPT resonances, which have distinct light shift coefficients, it is easy to detect light shift from the resonance frequency ratio of these two atomic resonances. Experimental results demonstrated the capability of the proposed method to simultaneously observe both the Ramsey-CPT and SCW-CPT resonances. The frequency difference attributable to the light shift was 308.9 Hz, indicating the successful detection of the light shift. Long-term measurements revealed that the frequency drift rates of the two atomic resonances differ by a factor of 3.5, and the variation in the frequency ratio enabled the detection of fluctuations in these two resonance frequencies.

DOI
10.35848/1347-4065/ad160a

Related papers

Estimation of a Light Shift Using Various Atomic Resonances in Ramsey-Coherent Population Trapping Sequence

Masahiro Fukuoka, Sigeyoshi Goka

This study aimed to detect the light shift by utilizing various atomic resonances observed under pulsed excitation with drive current modulation (DCM). Light shift degrades the performance of atomic clocks, and several studies have attempted to mitigate or correct it. Pulsed excitation with DCM facilitates the observation of various Ramsey-coherent population trapping (CPT) resonances owing to wavelength variation. Further, in the Ramsey-CPT sequence, a semi-continuous wave CPT resonance (SCW-CPT resonance), which is a continuous wave CPT resonance from pulsed lasers, is also observed. As these atomic resonances exhibit different frequency sensitivities to laser intensity, the frequency shifts differ based on the changes in laser intensity. This facilitates the detection of the light shift. By simultaneously measuring the resonance frequencies of two Ramsey-CPT resonances and the SCW-CPT resonance while varying the laser intensity to induce light shifts, we measured the resulting frequency changes. Each resonance exhibited a different frequency shift in response to the light shift. Therefore, this study conformed the feasibility of detecting and estimating the light shift in an operational atomic clock.

IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS)•Sep 22, 2024•0 citations

Ramsey–CPT Resonance Observation Using Different Laser Sideband Combinations for the Two Interrogation Pulses

Masahiro Fukuoka, Shigeyoshi Goka

SummaryWe investigated the Ramsey–coherent population trapping (CPT) characteristics of a new observation method that employs different laser sideband combinations as the two interrogation pulses during Ramsey–CPT resonance observation. In an experimental setup using a gas cell containing Cs atoms, Ramsey–CPT resonance was observed using the 1st-1stsideband combination for the common preparation pulse and the 1st-1stand C-2nd sideband combinations for the detection pulse. The Ramsey–CPT spectral shapes were inverted to each other. The light shift characteristic was 2.7 times different to its light sensitivity. This difference in the light shift characteristics is expected to allow the estimation of the light frequency shift in the Ramsey–CPT atomic clock during operation.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 24, 2022•2 citations

Light shift of Ramsey coherent population trapping resonance using drive current modulation

Masahiro Fukuoka, Shigeyoshi Goka, Masatoshi Kajita +1 more

Abstract We investigated the light shift of Ramsey coherent population trapping (CPT) resonance by drive current modulation (DCM), which can be realized with low power consumption in a small system, to improve the performance of a CPT atomic clock. The light shift makes the greatest contribution to the degradation of long-term frequency stability of a CPT atomic clock. We also devised digitizer-based DCM to reduce the uncertainty in the frequency of light shift due to wavelength variation at the time of observation. The results show that light shift with DCM is reduced compared with cw excitation and is consistent with theoretical calculations. The estimated frequency uncertainty of the light shift due to wavelength variation using the proposed method is 2.1 × 10−13, which is approximately 165 times better than that of the conventional method without a digitizer, thus demonstrating the effectiveness of the proposed method for future small atomic clocks.

Japanese Journal of Applied Physics•Nov 16, 2023•5 citations

Investigation on light shift in CPT-Ramsey resonance for compact atomic clocks

Yuichiro Yano, Wujie Gao, Shigeyoshi Goka +1 more

This paper presents a theoretical and experimental investigation on the light shift (AC Stark shift) of the 62S1/2(F = 3 ↔ 4) transition in133Cs, as observed through coherent population trapping (CPT) under a pulsed excitation. The calculated results are good agreement in the experimental results on various parameters and show that the light shift under pulsed excitation is 20∼30 times less than that under continuous excitation. In addition, this paper also presents a two-step pulse method for suppressing the light shift.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•0 citations

Protocol for Light-Shift Compensation in a Continuous-Wave Microcell Atomic Clock

Moustafa Abdel Hafiz, Rémy Vicarini, Nicolas Passilly +7 more

Light shifts are known to be an important limitation to the mid- and long-term fractional frequency stability of different types of atomic clocks. In this article, we demonstrate the experimental implementation of an anti-light-shift interrogation protocol onto a continuous-wave (cw) microcell atomic clock based on coherent population trapping (CPT). The method, inspired by the autobalanced Ramsey spectroscopy technique demonstrated in pulsed atomic clocks, consists in the extraction of atomic based information from two successive light-shifted clock frequencies obtained at two different laser-power values. Two error signals, computed from the linear combination of signals acquired along a symmetric sequence, are managed in a dual-loop configuration to generate a clock frequency free from light shift. Using this method, the sensitivity of the clock frequency to both laser-power and microwave-power variations can be reduced by more than an order of magnitude compared to normal operation. In the present experiment, the consideration of the nonlinear light-shift dependence allows enhancement of the light-shift mitigation. The implemented technique allows an improvement of the clock Allan deviation for time scales higher than 1000 s. This method can be applied in various kinds of atomic clocks such as CPT-based atomic clocks, double-resonance $\mathrm{Rb}$ clocks, or cell-stabilized lasers.

arXiv:2005.05096•Physical Review Applied•Sep 8, 2020•38 citations

Operation of a Ramsey-CPT microcell atomic clock with driving current-based power modulation of a VCSEL

C. M. Rivera-Aguilar, Martin Callejo, Andrei Mursa +6 more

We report on the operation of a coherent population trapping (CPT) microcell atomic clock using a pulsed Ramsey-like interrogation. The Ramsey-CPT sequence, defined by two-step optical pulses separated by a free-evolution dark time, is produced by switching on and off the output power of a low-power vertical-cavity surface-emitting laser, through direct modulation of its driving current. High-contrast and narrow Ramsey-CPT fringes are detected without the use of any external optical modulator stage. We demonstrate closed-loop operation of the clock based on high-speed digital signal processing implemented in a field programmable gate array board. The clock's short-term fractional frequency stability is 1.3 × 10−10τ−1/2 until 2000 s. A power light-shift coefficient of 8 × 10−11/μW, in relative value, is obtained for a dark time of 150 μs. This value is about ten times lower than in the continuous regime. These results show the feasibility of fully integrated atomic clocks based on Ramsey spectroscopy, which could provide enhanced long-term stability.

Applied Physics Letters•Mar 11, 2024•9 citations
Abstract In this study, we proposed a method to observe the semi-cw excited coherent population trapping (SCW-CPT) and the Ramsey-CPT resonance during a Ramsey pulse sequence. By simultaneously observing the Ramsey-CPT and SCW-CPT resonances, which have distinct light shift coefficients, it is easy to detect light shift from the resonance frequency ratio of these two atomic resonances. Experimental results demonstrated the capability of the proposed method to simultaneously observe both the Ramsey-CPT and SCW-CPT resonances. The frequency difference attributable to the light shift was 308.9 Hz, indicating the successful detection of the light shift. Long-term measurements revealed that the frequency drift rates of the two atomic resonances differ by a factor of 3.5, and the variation in the frequency ratio enabled the detection of fluctuations in these two resonance frequencies.
This study aimed to detect the light shift by utilizing various atomic resonances observed under pulsed excitation with drive current modulation (DCM). Light shift degrades the performance of atomic clocks, and several studies have attempted to mitigate or correct it. Pulsed excitation with DCM facilitates the observation of various Ramsey-coherent population trapping (CPT) resonances owing to wavelength variation. Further, in the Ramsey-CPT sequence, a semi-continuous wave CPT resonance (SCW-CPT resonance), which is a continuous wave CPT resonance from pulsed lasers, is also observed. As these atomic resonances exhibit different frequency sensitivities to laser intensity, the frequency shifts differ based on the changes in laser intensity. This facilitates the detection of the light shift. By simultaneously measuring the resonance frequencies of two Ramsey-CPT resonances and the SCW-CPT resonance while varying the laser intensity to induce light shifts, we measured the resulting frequency changes. Each resonance exhibited a different frequency shift in response to the light shift. Therefore, this study conformed the feasibility of detecting and estimating the light shift in an operational atomic clock.
SummaryWe investigated the Ramsey–coherent population trapping (CPT) characteristics of a new observation method that employs different laser sideband combinations as the two interrogation pulses during Ramsey–CPT resonance observation. In an experimental setup using a gas cell containing Cs atoms, Ramsey–CPT resonance was observed using the 1st-1stsideband combination for the common preparation pulse and the 1st-1stand C-2nd sideband combinations for the detection pulse. The Ramsey–CPT spectral shapes were inverted to each other. The light shift characteristic was 2.7 times different to its light sensitivity. This difference in the light shift characteristics is expected to allow the estimation of the light frequency shift in the Ramsey–CPT atomic clock during operation.
Abstract We investigated the light shift of Ramsey coherent population trapping (CPT) resonance by drive current modulation (DCM), which can be realized with low power consumption in a small system, to improve the performance of a CPT atomic clock. The light shift makes the greatest contribution to the degradation of long-term frequency stability of a CPT atomic clock. We also devised digitizer-based DCM to reduce the uncertainty in the frequency of light shift due to wavelength variation at the time of observation. The results show that light shift with DCM is reduced compared with cw excitation and is consistent with theoretical calculations. The estimated frequency uncertainty of the light shift due to wavelength variation using the proposed method is 2.1 × 10−13, which is approximately 165 times better than that of the conventional method without a digitizer, thus demonstrating the effectiveness of the proposed method for future small atomic clocks.
This paper presents a theoretical and experimental investigation on the light shift (AC Stark shift) of the 62S1/2(F = 3 ↔ 4) transition in133Cs, as observed through coherent population trapping (CPT) under a pulsed excitation. The calculated results are good agreement in the experimental results on various parameters and show that the light shift under pulsed excitation is 20∼30 times less than that under continuous excitation. In addition, this paper also presents a two-step pulse method for suppressing the light shift.
Light shifts are known to be an important limitation to the mid- and long-term fractional frequency stability of different types of atomic clocks. In this article, we demonstrate the experimental implementation of an anti-light-shift interrogation protocol onto a continuous-wave (cw) microcell atomic clock based on coherent population trapping (CPT). The method, inspired by the autobalanced Ramsey spectroscopy technique demonstrated in pulsed atomic clocks, consists in the extraction of atomic based information from two successive light-shifted clock frequencies obtained at two different laser-power values. Two error signals, computed from the linear combination of signals acquired along a symmetric sequence, are managed in a dual-loop configuration to generate a clock frequency free from light shift. Using this method, the sensitivity of the clock frequency to both laser-power and microwave-power variations can be reduced by more than an order of magnitude compared to normal operation. In the present experiment, the consideration of the nonlinear light-shift dependence allows enhancement of the light-shift mitigation. The implemented technique allows an improvement of the clock Allan deviation for time scales higher than 1000 s. This method can be applied in various kinds of atomic clocks such as CPT-based atomic clocks, double-resonance Rb\mathrm{Rb}Rb clocks, or cell-stabilized lasers.
We report on the operation of a coherent population trapping (CPT) microcell atomic clock using a pulsed Ramsey-like interrogation. The Ramsey-CPT sequence, defined by two-step optical pulses separated by a free-evolution dark time, is produced by switching on and off the output power of a low-power vertical-cavity surface-emitting laser, through direct modulation of its driving current. High-contrast and narrow Ramsey-CPT fringes are detected without the use of any external optical modulator stage. We demonstrate closed-loop operation of the clock based on high-speed digital signal processing implemented in a field programmable gate array board. The clock's short-term fractional frequency stability is 1.3 × 10−10τ−1/2 until 2000 s. A power light-shift coefficient of 8 × 10−11/μW, in relative value, is obtained for a dark time of 150 μs. This value is about ten times lower than in the continuous regime. These results show the feasibility of fully integrated atomic clocks based on Ramsey spectroscopy, which could provide enhanced long-term stability.