Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Simultaneous detection of multi-channel signals in MHz bandwidth using nitrogen-vacancy centers in a diamond

Bo Wang, Yuanyuan Shen, Dongqian Ke, Zhonghao Li, Huanfei Wen, Hao Guo, Jun Tang, Yanjun Li, Zongmin Ma, Jun Liu

Published Dec 14, 2023• 6 citations
Publisher

Abstract

In this paper, we propose a method for simultaneously recovering multiple radio wave signals based on nitrogen-vacancy (NV) centers in diamond combining optically detected magnetic resonance (ODMR) spectrum. A controlled magnetic field gradient applied to the laser excitation area on the surface of diamond widens the detectable ODMR bandwidth to 200 MHz. Three different frequency-modulated (FM) signals with distinct carrier frequencies falling within the resonance frequency range are received and demodulated in real-time. Subsequently, the FM signal reception capability of this system is further investigated by measuring baseband signal frequencies ranging from 0.1 Hz to 200 Hz and adjusting the carrier power within a dynamic range from -10 dBm to 30 dBm. This proposal, which accomplishes multi-channel demodulation using a compact and single device, has potential applications in fields such as wireless communication, radar and navigation.

DOI
10.1364/oe.511283

Related papers

Simultaneous Identification of Multiple Microwave Signals in 313-MHz Continuous Bandwidth Using Nitrogen-Vacancy Centers in Diamond

Y. W. Jin, Huan Fei Wen, Ding Wang +8 more

The efficient and reliable detection of microwave signals is a key element of the breakthrough in new-generation communication technology. In this article, we proposed an approach for the simultaneous identification of multiple microwave signals in a continuous frequency range based on the spectral hole-burning effect of nitrogen-vacancy (NV) centers. The protocol combines the quantum wide-field imaging method with magnetic gradient means, breaking the narrowband and discrete detection limitations of conventional optically detected magnetic resonance (ODMR) techniques. The frequencies of multiple microwave signals can be accurately decoupled by locating the relevant gaps on resonance frequency curves. Meanwhile, the effects induced by fixed-frequency signals with different powers on the resonance frequency curves were systematically analyzed. The experimental results indicated that the system realized a multiple-frequency resolution of 1 MHz and a minimum detectable power of 1 mW over a continuous bandwidth of 313-MHz. This proposal is capable of real-time and simultaneous detection of multiple microwave signals, which remarkably improves the utilization efficiency of spectrum resources.

IEEE Transactions on Microwave Theory and Techniques•Jul 30, 2024•0 citations

Wide bandwidth instantaneous radio frequency spectrum analyzer based on nitrogen vacancy centers in diamond

Mayeul Chipaux, Loïc Toraille, C. Larat +4 more

We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz, associated to a frequency resolution of 7 MHz , and a refresh rate of 4 ms. With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz, only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs.

arXiv:1509.01395•Applied Physics Letters•Dec 7, 2015•58 citations

Optical Detection of Multi‐Channel Digital Signals Using Nitrogen‐Vacancy Centers Array

Wenyuan Hao, Y. W. Jin, Huan Fei Wen +10 more

Abstract The efficient detection of digital signals plays a vital role in optimizing the reliability and stability of communication systems. This paper demonstrates a method to optically measure digital signals based on solid‐state quantum spin. The digital signals are non‐intrusively characterized by taking advantage of the optical readability of the spin states of the nitrogen‐vacancy (NV) centers array. Meanwhile, the resonance frequencies of optically detected magnetic resonance (ODMR) spectra are spatially encoded by means of an external magnetic field gradient, thereby realizing the simultaneous acquisition of three‐channel digital signals. Over a continuous detection bandwidth of 258 MHz, digital signals can be detected with a time resolution of 3 ms and a minimum signal strength of 0 dBm. Afterward, the ability of this system to capture digital signals is further substantiated by measuring signals in other channels. This proposal is competent for the simultaneous analysis of multi‐channel signals in real‐time and provides a valuable reference for radio spectrum monitoring, and signal intelligence reconnaissance.

Advanced Quantum Technologies•Jun 25, 2025•1 citation

High-frequency resolution diamond nitrogen-vacancy center wide-spectrum imaging technology

Yuanyuan Shen, Bo Wang, Dongqian Ke +10 more

High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.

Acta Physica Sinica•Jan 1, 2024•0 citations

Simultaneous Determination of Multiple Microwave Signals With High-Frequency Resolution Using Quantum Sensing Technique

Rui Zhao, Ding Wang, Huan Fei Wen +4 more

This article presents a method to simultaneously determine multiple microwave signals using the hole-burning effect based on nitrogen-vacancy (NV) centers in diamonds. Tracking the anomalous peaks caused by fixed-frequency microwave signals in the optically detected magnetic resonance spectrum, the frequencies under test can be detected with high precision and accuracy in real time. Meanwhile, the applicability of the scheme in detecting microwave signals of different power is evaluated systematically by adjusting the power of measured fixed-frequency microwave signals. In addition, the frequency resolution of the system is characterized by modulating the frequency of one of the microwave signals. The experiment results indicate that the frequency resolution is as small as 5 kHz and the recognition deviation is less than 0.40 kHz. The method will provide a new idea in the field of electromagnetic compatibility testing, radio signal processing, and Internet of Things Engineering.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2024•2 citations

Frequency-tunable magnetic field sensing using continuous-wave optically detected magnetic resonance with nitrogen-vacancy centers in diamond

Ryusei Okaniwa, Takumi Mikawa, Yuichiro Matsuzaki +8 more

The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetometry using continuous-wave optically detected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF)-dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with RF fields at two different frequencies. One creates the RF-dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF-dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on the RF field with a single frequency. The estimated bandwidth is 7.5 MHz, higher than that of the conventional method using the RF-dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.

arXiv:2305.12141•Journal of Applied Physics•Jan 22, 2024•7 citations
In this paper, we propose a method for simultaneously recovering multiple radio wave signals based on nitrogen-vacancy (NV) centers in diamond combining optically detected magnetic resonance (ODMR) spectrum. A controlled magnetic field gradient applied to the laser excitation area on the surface of diamond widens the detectable ODMR bandwidth to 200 MHz. Three different frequency-modulated (FM) signals with distinct carrier frequencies falling within the resonance frequency range are received and demodulated in real-time. Subsequently, the FM signal reception capability of this system is further investigated by measuring baseband signal frequencies ranging from 0.1 Hz to 200 Hz and adjusting the carrier power within a dynamic range from -10 dBm to 30 dBm. This proposal, which accomplishes multi-channel demodulation using a compact and single device, has potential applications in fields such as wireless communication, radar and navigation.
The efficient and reliable detection of microwave signals is a key element of the breakthrough in new-generation communication technology. In this article, we proposed an approach for the simultaneous identification of multiple microwave signals in a continuous frequency range based on the spectral hole-burning effect of nitrogen-vacancy (NV) centers. The protocol combines the quantum wide-field imaging method with magnetic gradient means, breaking the narrowband and discrete detection limitations of conventional optically detected magnetic resonance (ODMR) techniques. The frequencies of multiple microwave signals can be accurately decoupled by locating the relevant gaps on resonance frequency curves. Meanwhile, the effects induced by fixed-frequency signals with different powers on the resonance frequency curves were systematically analyzed. The experimental results indicated that the system realized a multiple-frequency resolution of 1 MHz and a minimum detectable power of 1 mW over a continuous bandwidth of 313-MHz. This proposal is capable of real-time and simultaneous detection of multiple microwave signals, which remarkably improves the utilization efficiency of spectrum resources.
We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz, associated to a frequency resolution of 7 MHz , and a refresh rate of 4 ms. With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz, only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs.
Abstract The efficient detection of digital signals plays a vital role in optimizing the reliability and stability of communication systems. This paper demonstrates a method to optically measure digital signals based on solid‐state quantum spin. The digital signals are non‐intrusively characterized by taking advantage of the optical readability of the spin states of the nitrogen‐vacancy (NV) centers array. Meanwhile, the resonance frequencies of optically detected magnetic resonance (ODMR) spectra are spatially encoded by means of an external magnetic field gradient, thereby realizing the simultaneous acquisition of three‐channel digital signals. Over a continuous detection bandwidth of 258 MHz, digital signals can be detected with a time resolution of 3 ms and a minimum signal strength of 0 dBm. Afterward, the ability of this system to capture digital signals is further substantiated by measuring signals in other channels. This proposal is competent for the simultaneous analysis of multi‐channel signals in real‐time and provides a valuable reference for radio spectrum monitoring, and signal intelligence reconnaissance.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
This article presents a method to simultaneously determine multiple microwave signals using the hole-burning effect based on nitrogen-vacancy (NV) centers in diamonds. Tracking the anomalous peaks caused by fixed-frequency microwave signals in the optically detected magnetic resonance spectrum, the frequencies under test can be detected with high precision and accuracy in real time. Meanwhile, the applicability of the scheme in detecting microwave signals of different power is evaluated systematically by adjusting the power of measured fixed-frequency microwave signals. In addition, the frequency resolution of the system is characterized by modulating the frequency of one of the microwave signals. The experiment results indicate that the frequency resolution is as small as 5 kHz and the recognition deviation is less than 0.40 kHz. The method will provide a new idea in the field of electromagnetic compatibility testing, radio signal processing, and Internet of Things Engineering.
The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetometry using continuous-wave optically detected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF)-dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with RF fields at two different frequencies. One creates the RF-dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF-dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on the RF field with a single frequency. The estimated bandwidth is 7.5 MHz, higher than that of the conventional method using the RF-dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.