Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Design of tightly linked dual ring antenna and imaging of magnetic field distribution using a diamond fiber probe

Qing-Yun 青云 Ye 叶, Ya-Wen 雅文 Xue 薛, Fei-Yue 飞越 He 何, Xu-Tong 旭彤 Zhao 赵, Yu-Chen 雨辰 Bian 卞, Wen-Tao 文韬 Lu 卢, Jin-Xu 金旭 Wang 王, Hong-Hao 鸿浩 Chen 陈, Sheng-Kai Xia, Ming-Jing 明菁 Zeng 曾, Guanxiang Du

Published Oct 27, 2023• 2 citations
Publisher

Abstract

A tightly linked dual ring antenna is designed, and it is specifically tailored for uniformly coupling the microwave magnetic field to the nitrogen-vacancy (NV) center. The designed antenna operates at a center frequency of about 2.87 GHz, with a bandwidth of around 200 MHz, allowing it to address multiple resonance peaks in the optically detected magnetic resonance (ODMR) spectrum in an external magnetic field. Moreover, the antenna generates a fairly uniform magnetic field in a range with a radius of 0.75 mm. High resolution imaging of the magnetic field distribution on the surface of the antenna is conducted by using a fiber diamond probe. We also investigate the effect of magnetic field uniformity on the linewidth of ODMR, so as to provide insights into reducing the inhomogeneous broadening of ODMR.

DOI
10.1088/1674-1056/ad0772

Related papers

Design of compact integrated diamond nitrogen–vacancy center quantum probe

Sheng-Kai Xia, Wen-Tao 文韬 Lu 卢, Xu-Tong 旭彤 Zhao 赵 +10 more

An integrated quantum probe for magnetic field imaging is proposed, where the nitrogen–vacancy (NV) center fixed at the fiber tip is located on the periphery of flexible ring resonator. Using flexible polyimide (PI) as the substrate medium, we design a circular microstrip antenna, which can achieve a bandwidth of 140 MHz at Zeeman splitting frequency of 2.87 GHz, specifically suitable for NV center experiments. Subsequently, this antenna is seamlessly fixed at a three-dimensional-printed cylindrical support, allowing the optical fiber tip to extend out of a dedicated aperture. To mitigate errors originating from processing, precise tuning within a narrow range can be achieved by adjusting the conformal amplitude. Finally, we image the microwave magnetic field around the integrated probe with high resolution, and determine the suitable area for placing the fiber tip (SAP).

Chinese Physics B•Feb 22, 2024•6 citations

Tunable double split-ring resonator for quantum sensing using nitrogen-vacancy centers in diamond

Yan Yang, Qin Wu, Yangpeng Wang +5 more

For quantum sensing based on nitrogen-vacancies (NV) ensembles, microwave antennas can couple the microwave field to the NV center, which leads it to becoming the core of spin manipulation and can directly affect the sensitivity of quantum sensing. The double split-ring resonator is a widely used microwave device for NV ensembles due to the advantages of high radiation efficiency and uniform magnetic field in millimeter-scale areas. But the bandwidth (30 MHz) is quite narrow which limits the application in quantum sensing with NV ensembles. Here, we experimentally achieve continuous tuning of the resonant frequency of the double split-ring resonator by changing the copper sheet position on the edge of the outer ring. The frequency tuning range can reach 80 MHz, up to 2-3 times the bandwidth, which can cover the transition of the electron spin under different magnetic field conditions. The performance of the tunable antenna in the quantum operation of NV centers is verified by optically detected magnetic resonance and Rabi oscillation. This tunable antenna is promising in the fabrication of integrated and arrayed quantum sensors based on NV ensembles.

Optics Continuum•May 16, 2023•10 citations

High-frequency resolution diamond nitrogen-vacancy center wide-spectrum imaging technology

Yuanyuan Shen, Bo Wang, Dongqian Ke +10 more

High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.

Acta Physica Sinica•Jan 1, 2024•0 citations

High-resolution magnetic field imaging with a nitrogen-vacancy diamond sensor integrated with a photonic-crystal fiber

И. В. Федотов, Sean M. Blakley, Evgenii E. Serebryannikov +3 more

We demonstrate high-resolution magnetic field imaging with a scanning fiber-optic probe which couples nitrogen-vacancy (NV) centers in diamond to a high-numerical-aperture photonic-crystal fiber integrated with a two-wire microwave transmission line. Magnetic resonance excitation of NV centers driven by the microwave field is read out through optical interrogation through the photonic-crystal fiber to enable high-speed, high-sensitivity magnetic field imaging with sub 30 μm spatial resolution.

Optics Letters•Jan 22, 2016•50 citations

Broadband AC Magnetic Field Sensing via Continuous wave optically detected magnetic resonance with NV Centers in diamond

Ryohei Dokai, Ryusei Okaniwa, Miku Ishizaki +2 more

The nitrogen-vacancy (NV) center in diamond has attracted considerable attention as a highly sensitive quantum sensor that can operate at room temperature. In particular, continuous-wave optically detected magnetic resonance (CW-ODMR) is promising for a wide range of applications because of its simplicity. However, conventional AC magnetic-field sensing schemes based on CW-ODMR suffer from a limited detection bandwidth: the detectable frequency is either fixed by intrinsic physical parameters of the NV center or, even when tunable, restricted to a narrow range of only a few MHz. Here, we propose a broadband AC magnetometry scheme based on CW-ODMR with NV centers using microwave-driven dressed states.Through theoretical analysis and numerical simulations, we show that the proposed scheme enables the detection of AC magnetic fields with frequencies up to the order of 100 MHz, which has been difficult to achieve using conventional CW-ODMR-based methods.

quant-pharXiv:2606.05928•Japanese Journal of Applied Physics•Jun 5, 2026•0 citations

High efficiency radio frequency antennas for amplifier free quantum sensing applications

Sheikh Shahparan Mahtab, Peker Milas, D. Tim Veal +2 more

Radio frequency (RF) signals are frequently used in emerging quantum applications due to their spin state manipulation capability. Efficient coupling of RF signals into a particular quantum system requires the utilization of carefully designed and fabricated antennas. Nitrogen vacancy (NV) defects in diamond are commonly utilized platforms in quantum sensing experiments with the optically detected magnetic resonance (ODMR) method, where an RF antenna is an essential element. We report on the design and fabrication of high efficiency coplanar RF antennas for quantum sensing applications. Single and double ring coplanar RF antennas were designed with -37 dB experimental return loss at 2.87 GHz, the zero-field splitting frequency of the negatively charged NV defect in diamond. The efficiency of both antennas was demonstrated in magnetic field sensing experiments with NV color centers in diamond. An RF amplifier was not needed, and the 0 dB output of a standard RF signal generator was adequate to run the ODMR experiments due to the high efficiency of the RF antennas.

Review of Scientific Instruments•Apr 1, 2023•5 citations
A tightly linked dual ring antenna is designed, and it is specifically tailored for uniformly coupling the microwave magnetic field to the nitrogen-vacancy (NV) center. The designed antenna operates at a center frequency of about 2.87 GHz, with a bandwidth of around 200 MHz, allowing it to address multiple resonance peaks in the optically detected magnetic resonance (ODMR) spectrum in an external magnetic field. Moreover, the antenna generates a fairly uniform magnetic field in a range with a radius of 0.75 mm. High resolution imaging of the magnetic field distribution on the surface of the antenna is conducted by using a fiber diamond probe. We also investigate the effect of magnetic field uniformity on the linewidth of ODMR, so as to provide insights into reducing the inhomogeneous broadening of ODMR.
An integrated quantum probe for magnetic field imaging is proposed, where the nitrogen–vacancy (NV) center fixed at the fiber tip is located on the periphery of flexible ring resonator. Using flexible polyimide (PI) as the substrate medium, we design a circular microstrip antenna, which can achieve a bandwidth of 140 MHz at Zeeman splitting frequency of 2.87 GHz, specifically suitable for NV center experiments. Subsequently, this antenna is seamlessly fixed at a three-dimensional-printed cylindrical support, allowing the optical fiber tip to extend out of a dedicated aperture. To mitigate errors originating from processing, precise tuning within a narrow range can be achieved by adjusting the conformal amplitude. Finally, we image the microwave magnetic field around the integrated probe with high resolution, and determine the suitable area for placing the fiber tip (SAP).
For quantum sensing based on nitrogen-vacancies (NV) ensembles, microwave antennas can couple the microwave field to the NV center, which leads it to becoming the core of spin manipulation and can directly affect the sensitivity of quantum sensing. The double split-ring resonator is a widely used microwave device for NV ensembles due to the advantages of high radiation efficiency and uniform magnetic field in millimeter-scale areas. But the bandwidth (30 MHz) is quite narrow which limits the application in quantum sensing with NV ensembles. Here, we experimentally achieve continuous tuning of the resonant frequency of the double split-ring resonator by changing the copper sheet position on the edge of the outer ring. The frequency tuning range can reach 80 MHz, up to 2-3 times the bandwidth, which can cover the transition of the electron spin under different magnetic field conditions. The performance of the tunable antenna in the quantum operation of NV centers is verified by optically detected magnetic resonance and Rabi oscillation. This tunable antenna is promising in the fabrication of integrated and arrayed quantum sensors based on NV ensembles.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
The nitrogen-vacancy (NV) center in diamond has attracted considerable attention as a highly sensitive quantum sensor that can operate at room temperature. In particular, continuous-wave optically detected magnetic resonance (CW-ODMR) is promising for a wide range of applications because of its simplicity. However, conventional AC magnetic-field sensing schemes based on CW-ODMR suffer from a limited detection bandwidth: the detectable frequency is either fixed by intrinsic physical parameters of the NV center or, even when tunable, restricted to a narrow range of only a few MHz. Here, we propose a broadband AC magnetometry scheme based on CW-ODMR with NV centers using microwave-driven dressed states.Through theoretical analysis and numerical simulations, we show that the proposed scheme enables the detection of AC magnetic fields with frequencies up to the order of 100 MHz, which has been difficult to achieve using conventional CW-ODMR-based methods.
Radio frequency (RF) signals are frequently used in emerging quantum applications due to their spin state manipulation capability. Efficient coupling of RF signals into a particular quantum system requires the utilization of carefully designed and fabricated antennas. Nitrogen vacancy (NV) defects in diamond are commonly utilized platforms in quantum sensing experiments with the optically detected magnetic resonance (ODMR) method, where an RF antenna is an essential element. We report on the design and fabrication of high efficiency coplanar RF antennas for quantum sensing applications. Single and double ring coplanar RF antennas were designed with -37 dB experimental return loss at 2.87 GHz, the zero-field splitting frequency of the negatively charged NV defect in diamond. The efficiency of both antennas was demonstrated in magnetic field sensing experiments with NV color centers in diamond. An RF amplifier was not needed, and the 0 dB output of a standard RF signal generator was adequate to run the ODMR experiments due to the high efficiency of the RF antennas.