Preliminary studies of Rb microfabricated cells for a two-photon Rb optical frequency reference

Martin Callejo, Rémy Vicarini, Philippe Abbé, Nicolas Passilly, Rodolphe Boudot

Published May 15, 2023• 0 citations
OpenAlex

Abstract

Doppler-free two-photon absorption spectroscopy is employed to characterize the purity of rubidium vapor micro-fabricated cells. The observed broadening suggests the presence of impurities and contaminants in the cell.

Related papers

Rb microfabricated cells for a two-photon optical frequency reference

Martin Callejo, Rémy Vicarini, Andrei Mursa +4 more

Miniaturized vapor cell optical clocks based on the use of the two photon absorption transition (TPT) of the Rb atom at 778 nm have recently demonstrated remarkable stability results.

•Jun 18, 2023•0 citations

Short-term stability of a microcell optical reference based on Rb atom two-photon transition at 778 nm

Martin Callejo, Andrei Mursa, Rémy Vicarini +5 more

We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5 $\times$ 10$^{-13}$ $τ^{-1/2}$ until 200~s, in good agreement with a phase noise level of $+$ 43 dBrad$^2$/Hz at 1~Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. With still a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.

arXiv:2407.00841•Jun 30, 2024•0 citations

Microfabrication of 85Rb vapor cell for chip-scale atomic clocks

Juan Su, Ke Deng, Zhong Wang +1 more

We describe the fabrication of Rubidium (Rb) vapor cells using glass-silicon anodic bonding techniques and chemical reaction between rubidium chloride and barium azide. The pure metallic Rb drops and buffer gases were obtained in the cells with few mm3internal volumes. The optical absorption resonance of85Rb D1 transition with proper broadening and the corresponding coherent population trapping (CPT) resonance, with a signal contrast of 1.5% and linewidth of about 1.7 KHz, have been detected at 90degC.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•8 citations

Short-term stability of a microcell optical reference based on the Rb atom two-photon transition at 778 nm

Martin Callejo, Andrei Mursa, Rémy Vicarini +5 more

We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.

Journal of the Optical Society of America B•Nov 22, 2024•14 citations

Microfabricated saturated absorption laser spectrometer

Svenja A. Knappe, H. G. Robinson, Leo W. Hollberg

We demonstrate a miniature microfabricated saturated absorption laser spectrometer. The system consists of miniature optics, a microfabricated Rb vapor cell, heaters, and a photodetector, all contained within a volume of 0.1 cm(3). Saturated absorption spectra were measured with a diode laser at 795 nm. They are comparable to signals obtained with standard table-top setups, although the rubidium vapor cell has an interior volume of only 1 mm(3). We discuss the performance and prospects for using such systems as a miniature optical wavelength reference, compatible with transportable instruments.

Optics Express•Jan 1, 2007•50 citations

Observation of a Frequency-Shift in Rb Absorption Spectrum using an Optical Nanofiber in a Vapor Cell

Amy Watkins, Kieran Deasy, Jonathan M. Ward +1 more

We present results obtained using a tapered optical fiber to observe the atom-surface interactions of a hot rubidium vapor. A frequency shift in the absorption spectrum as a function of rubidium vapor density is investigated.

Frontiers in Optics•Jan 1, 2010•0 citations
We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5 ×\times× 10−13^{-13}−13 τ−1/2τ^{-1/2}τ−1/2 until 200~s, in good agreement with a phase noise level of +++ 43 dBrad2^22/Hz at 1~Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. With still a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.
We describe the fabrication of Rubidium (Rb) vapor cells using glass-silicon anodic bonding techniques and chemical reaction between rubidium chloride and barium azide. The pure metallic Rb drops and buffer gases were obtained in the cells with few mm3internal volumes. The optical absorption resonance of85Rb D1 transition with proper broadening and the corresponding coherent population trapping (CPT) resonance, with a signal contrast of 1.5% and linewidth of about 1.7 KHz, have been detected at 90degC.
We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.
We demonstrate a miniature microfabricated saturated absorption laser spectrometer. The system consists of miniature optics, a microfabricated Rb vapor cell, heaters, and a photodetector, all contained within a volume of 0.1 cm(3). Saturated absorption spectra were measured with a diode laser at 795 nm. They are comparable to signals obtained with standard table-top setups, although the rubidium vapor cell has an interior volume of only 1 mm(3). We discuss the performance and prospects for using such systems as a miniature optical wavelength reference, compatible with transportable instruments.