Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Applying Kerr Squeezed Light to Interferometry

Nikolay A. Kalinin, Thomas Dirmeier, Arseny A. Sorokin, Elena A. Anashkina, Luis Lorenzo Sánchez-Soto, Joel Frederick Corney, Gerd Leuchs, Alexey V. Andrianov

Published Jun 26, 2023• 0 citations
Publisher

Abstract

One of the most promising applications for squeezed light is interferometry beyond the shot-noise limit (SNL). To date, only squeezed light generated by parametric down-conversion has been used to improve interferometer sensitivity. Remarkable results have been achieved with this approach, including applications to large-scale gravitational wave detectors. On the other hand, there exists a potentially more robust way to generate squeezed light, that is, using the optical Kerr effect. It occurs almost for free in optical fibers and requires no phase matching. However, no interferometer sensitivity enhancement has been demonstrated so far using this method. One of the reasons for that is that the uncertainty distribution of a Kerr-squeezed state in phase space is tilted with respect to the amplitude or phase quadratures. Additional obstacles include Raman and guided acoustic wave Brillouin scattering in fibers.

DOI
10.1109/cleo/europe-eqec57999.2023.10232130

Related papers

Quantum‐enhanced interferometer using Kerr squeezing

Nikolay A. Kalinin, Thomas Dirmeier, Arseny A. Sorokin +5 more

One of the prime applications of squeezed light is enhancing the sensitivity of an interferometer below the quantum shot-noise limit, but so far, no such experimental demonstration was reported when using the optical Kerr effect. In prior setups involving Kerr-squeezed light, the role of the interferometer was merely to characterize the noise pattern. The lack of such a demonstration was largely due to the cumbersome tilting of the squeezed ellipse in phase space. Here, we present the first experimental observation of phase-sensitivity enhancement in an interferometer using Kerr squeezing.

Nanophotonics•Apr 10, 2023•35 citations

Enhancing Interferometer Sensitivity Using Kerr Squeezing in Fibers

Nikolay A. Kalinin, Thomas Dirmeier, Luis Lorenzo Sánchez-Soto +2 more

We present an all-fiber robust setup for polarization squeezing generation using the Kerr effect in fibers. For the first time, a third-order nonlinearity is used to demonstrate interferometer sensitivity enhancement beyond the shot noise limit.

Quantum 2.0 Conference and Exhibition•Jan 1, 2023•0 citations

Squeezed light and laser interferometric gravitational wave detectors

S. Chelkowski

Based on the General Theory of Relativity Albert Einstein predicted the existence of gravitational waves as early as 1916.It took until now to develop large-scale interferometric gravitational wave (GW) detectors with sensitivities which would allow a direct measurement of a GW caused by an astrophysical event, such as a nearby supernova explosion.GW detectors have steadily improved over recent years and are currently producing a continuous stream of scientifically relevant data.The limiting noise in the higher frequency range of the GW detection band is shot noise, which is caused by vacuum fluctuations entering the detector through its dark port.Current GW detectors use high-power lasers to reduce shot noise.In addition, techniques such as power recycling and signal recycling have been developed.These techniques increase the laser power in the interferometer arms and amplify the GW induced signal sidebands respectively, to increase the shot noise limited sensitivity even further.In 1981 Caves proposed using squeezed light to reduce the vacuum fluctuations, thereby increasing the signal-to-noise ratio of the GW detector.The generation of squeezed states was first experimentally demonstrated by Slusher et al. in 1985.Since then, the technique of squeezing has evolved and today it can be used as a tool in real applications such as GW detection.It is planned to use squeezed light in future generations of GW detectors to enhance their sensitivity beyond quantum noise.This thesis analyzes and demonstrates the compatibility of squeezed light and advanced techniques of high-precision laser interferometry for GW detection.Initially, an optical parametric amplifier (OPA) is set up to produce the desired squeezed states of light (Chapter 3).This source is characterized-and consequently optimized-to deliver a maximum squeezing strength of up to 5.7 dB.The detuned signal-recycling cavity of GEO 600 and future GW detectors inevitably requires study of the effects caused by reflection of an initially frequency-independent squeezed state of light at such a cavity.The squeezing ellipse orientation of the reflected light is frequency-dependent; consequently, the sensitivity of the GW detector is only enhanced in a small frequency range.In Chapter 4 such frequency-dependent squeezed states are generated and characterized.The demonstration of a squeezed-light-enhanced dual-recycled Michelson interferometer with a broadband improved sensitivity is presented in Chapter 5. Here, a smaller version of GEO 600, downsized by a factor of 1000, is set up as a tabletop experiment.A detuned filter cavity is used to compensate the effects of the signal-recycling cavity, which results in a non-classical sensitivity improvement in the entire frequency band of interest.The enhancement of a large scale GW detector demands the availability of squeezed light in the GW detection band from 10 Hz-10 kHz.Chapter 6 describes the newly developed locking scheme required for the generation of such low-frequency squeezing, along with the results obtained.Finally, an outlook is given in Chapter 7 of the possible performance increase of the next generation GW detector, GEO-HF, due to squeezed-light injection.Different options for filter cavities and their implementation in the current vacuum system are discussed, as well as a detuned twin-signal-recycling option.

•Jan 1, 2007•16 citations

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, H. J. Kimble

Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.

Annual Meeting Optical Society of America•Jan 1, 1987•3 citations

Gravitational-wave detection beyond the quantum shot-noise limit : the integration of squeezed light in GEO 600

Emil Schreiber

The first detections of gravitational waves have opened an exciting new field of astronomy. One of the most fundamental limitations for the sensitivity of current and future interferometric gravitational-wave detectors is imposed by the quantum nature of light: Quantum vacuum fluctuations entering the interferometer through the readout port will contribute to the detection noise, at high frequencies in the form of shot noise and at low frequencies by radiation pressure noise. A promising way to reduce this quantum noise is the injection of squeezed states of light that have a lower uncertainty in one quadrature than the vacuum state. The GEO 600 gravitational-wave detector demonstrated the use of squeezed light in 2010 and it is now the first detector to routinely apply squeezing to improve its sensitivity beyond the limits set by classical quantum shot noise. This thesis details the practical aspects of long-term stable and efficient squeezed-light integration in a large-scale gravitational-wave detector. Imperfections that can limit the amount of observable non-classical noise improvement, such as optical losses and phase fluctuations, were studied in detail and methods for their mitigation were developed. Novel control schemes for the active stabilisation of the squeezed light field's phase and alignment were one main focus of the investigations. At the same time, important experience was gathered in the operation of the squeezed light source over long timescales. Over the course of the thesis work, improvements were implemented that significantly increased the performance of the squeezed-light application. Squeezing was injected with an overall duty cycle of 88%, reaching a noise reduction of up to 4.4 dB, corresponding to a 40% lowered shot-noise level. This work has firmly established the practical application of squeezing as a mature technology. The gained knowledge will directly inform the implementation of squeezed light for all future gravitational-wave detectors.

•Jan 1, 2018•15 citations

Squeezed Light for Future Gravitational Wave Detectors

Fabian Meylahn, B. Willke, H. Vahlbruch

Squeezed vacuum states of light show a reduction in quantum noise along one quadrature compared to the vacuum state. This characteristic is the key to improve interferometric measurements beyond their quantum noise limitation. In particular for ground-based gravitational wave detectors [1] the application of squeezed light led to a significant sensitivity improvement of up to 6 dB. Future gravitational wave detectors, like the Einstein Telescope [2] or Cosmic Explorer [3], aim for an even higher enhancement in the range of 10 dB with the injection of squeezed states of light into the dark port of their interferometers.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•0 citations
One of the most promising applications for squeezed light is interferometry beyond the shot-noise limit (SNL). To date, only squeezed light generated by parametric down-conversion has been used to improve interferometer sensitivity. Remarkable results have been achieved with this approach, including applications to large-scale gravitational wave detectors. On the other hand, there exists a potentially more robust way to generate squeezed light, that is, using the optical Kerr effect. It occurs almost for free in optical fibers and requires no phase matching. However, no interferometer sensitivity enhancement has been demonstrated so far using this method. One of the reasons for that is that the uncertainty distribution of a Kerr-squeezed state in phase space is tilted with respect to the amplitude or phase quadratures. Additional obstacles include Raman and guided acoustic wave Brillouin scattering in fibers.
One of the prime applications of squeezed light is enhancing the sensitivity of an interferometer below the quantum shot-noise limit, but so far, no such experimental demonstration was reported when using the optical Kerr effect. In prior setups involving Kerr-squeezed light, the role of the interferometer was merely to characterize the noise pattern. The lack of such a demonstration was largely due to the cumbersome tilting of the squeezed ellipse in phase space. Here, we present the first experimental observation of phase-sensitivity enhancement in an interferometer using Kerr squeezing.
Based on the General Theory of Relativity Albert Einstein predicted the existence of gravitational waves as early as 1916.It took until now to develop large-scale interferometric gravitational wave (GW) detectors with sensitivities which would allow a direct measurement of a GW caused by an astrophysical event, such as a nearby supernova explosion.GW detectors have steadily improved over recent years and are currently producing a continuous stream of scientifically relevant data.The limiting noise in the higher frequency range of the GW detection band is shot noise, which is caused by vacuum fluctuations entering the detector through its dark port.Current GW detectors use high-power lasers to reduce shot noise.In addition, techniques such as power recycling and signal recycling have been developed.These techniques increase the laser power in the interferometer arms and amplify the GW induced signal sidebands respectively, to increase the shot noise limited sensitivity even further.In 1981 Caves proposed using squeezed light to reduce the vacuum fluctuations, thereby increasing the signal-to-noise ratio of the GW detector.The generation of squeezed states was first experimentally demonstrated by Slusher et al. in 1985.Since then, the technique of squeezing has evolved and today it can be used as a tool in real applications such as GW detection.It is planned to use squeezed light in future generations of GW detectors to enhance their sensitivity beyond quantum noise.This thesis analyzes and demonstrates the compatibility of squeezed light and advanced techniques of high-precision laser interferometry for GW detection.Initially, an optical parametric amplifier (OPA) is set up to produce the desired squeezed states of light (Chapter 3).This source is characterized-and consequently optimized-to deliver a maximum squeezing strength of up to 5.7 dB.The detuned signal-recycling cavity of GEO 600 and future GW detectors inevitably requires study of the effects caused by reflection of an initially frequency-independent squeezed state of light at such a cavity.The squeezing ellipse orientation of the reflected light is frequency-dependent; consequently, the sensitivity of the GW detector is only enhanced in a small frequency range.In Chapter 4 such frequency-dependent squeezed states are generated and characterized.The demonstration of a squeezed-light-enhanced dual-recycled Michelson interferometer with a broadband improved sensitivity is presented in Chapter 5. Here, a smaller version of GEO 600, downsized by a factor of 1000, is set up as a tabletop experiment.A detuned filter cavity is used to compensate the effects of the signal-recycling cavity, which results in a non-classical sensitivity improvement in the entire frequency band of interest.The enhancement of a large scale GW detector demands the availability of squeezed light in the GW detection band from 10 Hz-10 kHz.Chapter 6 describes the newly developed locking scheme required for the generation of such low-frequency squeezing, along with the results obtained.Finally, an outlook is given in Chapter 7 of the possible performance increase of the next generation GW detector, GEO-HF, due to squeezed-light injection.Different options for filter cavities and their implementation in the current vacuum system are discussed, as well as a detuned twin-signal-recycling option.
Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.
The first detections of gravitational waves have opened an exciting new field of astronomy. One of the most fundamental limitations for the sensitivity of current and future interferometric gravitational-wave detectors is imposed by the quantum nature of light: Quantum vacuum fluctuations entering the interferometer through the readout port will contribute to the detection noise, at high frequencies in the form of shot noise and at low frequencies by radiation pressure noise. A promising way to reduce this quantum noise is the injection of squeezed states of light that have a lower uncertainty in one quadrature than the vacuum state. The GEO 600 gravitational-wave detector demonstrated the use of squeezed light in 2010 and it is now the first detector to routinely apply squeezing to improve its sensitivity beyond the limits set by classical quantum shot noise. This thesis details the practical aspects of long-term stable and efficient squeezed-light integration in a large-scale gravitational-wave detector. Imperfections that can limit the amount of observable non-classical noise improvement, such as optical losses and phase fluctuations, were studied in detail and methods for their mitigation were developed. Novel control schemes for the active stabilisation of the squeezed light field's phase and alignment were one main focus of the investigations. At the same time, important experience was gathered in the operation of the squeezed light source over long timescales. Over the course of the thesis work, improvements were implemented that significantly increased the performance of the squeezed-light application. Squeezing was injected with an overall duty cycle of 88%, reaching a noise reduction of up to 4.4 dB, corresponding to a 40% lowered shot-noise level. This work has firmly established the practical application of squeezing as a mature technology. The gained knowledge will directly inform the implementation of squeezed light for all future gravitational-wave detectors.
Squeezed vacuum states of light show a reduction in quantum noise along one quadrature compared to the vacuum state. This characteristic is the key to improve interferometric measurements beyond their quantum noise limitation. In particular for ground-based gravitational wave detectors [1] the application of squeezed light led to a significant sensitivity improvement of up to 6 dB. Future gravitational wave detectors, like the Einstein Telescope [2] or Cosmic Explorer [3], aim for an even higher enhancement in the range of 10 dB with the injection of squeezed states of light into the dark port of their interferometers.