Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Optically pumped magnetometers based on pseudo-random-bit-sequence phase modulation

Ning Ma, Lihong Duan, Xiujie Fang, Bozheng Xing, Danyue Ma, Jixi Lu, Bangcheng Han

Published Aug 14, 2023• 12 citations
Publisher

Abstract

A high-sensitivity atomic magnetometer based on broad linewidth laser pumping is demonstrated. The broad linewidth laser was obtained by broadening a narrow linewidth laser utilizing an external phase modulator driven by a pseudo-random-bit-sequence (PRBS) waveform. This ingenious optical pumping scheme can significantly enhance the signal response and suppress light shift noise, as well as can reduce the gradient of electron spin polarization and improve the stability of magnetometers. Compared with a narrow linewidth laser pumping scheme, the response of the magnetometer is increased by 56%, experimentally. The relative polarization gradient is reduced from 9.8%/cm to better than 4%/cm by setting PRBS with a bit rate of 16 GHz. This scheme can also be applied to many other fields such as noninvasive bio-magnetic imaging and atomic spin gyroscopes.

DOI
10.1063/5.0164896

Related papers

Enhancing the sensitivity of spin-exchange relaxation-free magnetometers using phase-modulated pump light with external Gaussian noise

Ning Ma, Xiujie Fang, Yaqi Zhang +5 more

An optical pumping scheme is proposed for reducing the gradient of electron spin polarization and suppressing light source noise in a spin-exchange relaxation-free magnetometer. This is achieved by modulating only the phase of a narrow-linewidth pump light field with external Gaussian noise. Compared to the absence of phase modulation, the uniformity of electron spin polarization was improved by over 40%, and the light-frequency noise suppression ratio of the magnetometer was enhanced by 4.3 times. Additionally, the response of the magnetometer was increased by 54%, resulting in a sensitivity of 0.34 fT/Hz 1/2 at 30 Hz. The applicability of this scheme can extend to other optical pumping experiments involving large atom ensembles requiring uniform electron spin polarization distribution, which is beneficial for developing ultra-high sensitivity and high stability magnetometers essential for magneto-cardiography and magneto-encephalography research applications.

Optics Express•Sep 3, 2024•79 citations

Suppressing virtual magnetic field noise and enhancing spin coherence in hybrid optical pumping atomic magnetometers

Faming Wang, Xiujie Fang, Yueyang Zhai +5 more

A hybrid optical pumping method employing a broad linewidth laser is proposed to enhance spin coherence and suppress virtual magnetic field noise in atomic magnetometers. The central frequency of broad linewidth laser is tuned to the resonance peak of the alkali-metal atoms D1 line. Its multiple frequency components suppress AC-Stark shift fluctuations caused by pumping laser frequency variations, thereby reducing virtual magnetic field noise. In addition, these components decrease the average optical absorption cross-section, improving the uniformity of atomic spin polarization, further enhancing spin coherence and extending transverse relaxation time. Experimental results show that, compared with narrow linewidth pumping, the proposed method suppresses virtual magnetic field noise by 17.95% to 34.50%, and increases the magnetometer response by 1.62% to 30.31% at 5 Hz. The average sensitivity within the frequency range of 1-20 Hz is improved to 0.158 fT/Hz 1/2 , representing a significant enhancement of 30.70% compared to narrow linewidth pumping.

EPJ Quantum Technology•Jun 2, 2026•0 citations

Broadband optically pumped NMR gyroscope technique based on Gaussian white noise phase modulation

Tong Huo, Jianhua Yang, Zhihang Zhang +4 more

This work proposes an optical pumping strategy based on a broadband laser to overcome the problem of atomic spin polarization gradients and sensitivity to optical frequency noise in NMR gyroscopes. A band-limited Gaussian white noise radiofrequency signal is applied to a lithium niobate electro-optic phase modulator to do this. A narrow linewidth laser maintains its frequency stability while uniformly broadening its spectrum to the hundreds of MHz range. Compared to unmodulated pumping, the proposed scheme enhances the uniformity of rubidium spin polarization by approximately 10%, reaching a measured value of 92.8%. Additionally, the sensitivity of the inert gas precession signal to optical frequency noise is reduced by half. This scheme can be extended to other atomic sensors requiring higher uniform spin polarization distributions and provides a promising way to achieve high-stability, low-noise NMR gyroscope systems.

Applied Optics•Sep 18, 2025•1 citation

Light-induced line narrowing of the magnetic resonance in a parametric resonance optically pumped rubidium magnetometer

Yongbiao Yang, Yang Li, Zhengyu Su +4 more

Optically pumped atomic magnetometers are fundamentally limited by spin-exchange relaxation in finite magnetic fields. In conventional parametric resonance magnetometers (PRMs), this relaxation dominates the resonance linewidth, producing broad profiles that degrade sensitivity. Here, we suppress this relaxation by incorporating light narrowing via optical pumping into spin-stretched states in a longitudinally modulated PRM, which directly enables dual-axis vector detection of transverse magnetic fields through lock-in demodulation. Under optimized conditions, the magnetometer achieves transverse sensitivities of $210\phantom{\rule{4pt}{0ex}}\mathrm{fT}/\sqrt{\mathrm{Hz}}$ and $290\phantom{\rule{4pt}{0ex}}\mathrm{fT}/\sqrt{\mathrm{Hz}}$ along two orthogonal axes, a 3-dB bandwidth of about $500\phantom{\rule{4pt}{0ex}}\mathrm{Hz}$, and excellent cross-axis discrimination---an order-of-magnitude improvement over conventional PRMs. This work demonstrates that light narrowing effectively overcomes the spin-exchange limitation in finite-field operation, providing a promising route for high-sensitivity vector magnetometry in applications such as atomic gyroscopes and active magnetic compensation.

Physical Review A•Oct 28, 2026•0 citations

Compact, high-sensitivity atomic magnetometer utilizing the light-narrowing effect and in-phase excitation

Yuhao Guo, Shuangai Wan, Xiaoguang Sun +1 more

A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.

Applied Optics•Jan 22, 2019•30 citations

Femtotesla atomic magnetometer with counter-propagating optical sideband pumping

Jin Peng, An‐Ning Xu, Bei Liu

The ultrasensitive magnetometer has a vital importance in fundamental research and applications. Currently, the spin-exchange relaxation-free (SERF) atomic magnetometer has been reported with a sensitivity around the level of fT/Hz 1/2 . To enhance the sensitivity, a gradiometer configuration has usually been introduced to cancel the common-mode noise between two separate channels. However, the signal and response from different channels are not the same due to the attenuation of the pump beam. Here, we proposed a counter-propagating optical sideband pumping method to polarize the atoms, using the electro-optic modulator to modulate the single-pump beam, generating two symmetrically red- and blue-detuned sidebands of frequency. This scheme leads to a significant reduction of undesirable effects coming along with the optical pumping, such as light shifts and spatial inhomogeneity in atomic spin polarization. With the help of this pumping scheme, the two channels have the same magnetic response, and we have built a gradiometer atomic magnetometer with a sensitivity of 0.5 fT/Hz 1/2 ranging from 5 to 40 Hz. Our results propose the possibility of creating larger arrays of atomic magnetometers (AMs) with high sensitivity and spatial resolution based on single-vapor cells for magnetocardiography and magnetoencephalography imaging or searching for exotic spin-dependent interactions.

Optics Letters•Oct 24, 2024•10 citations
A high-sensitivity atomic magnetometer based on broad linewidth laser pumping is demonstrated. The broad linewidth laser was obtained by broadening a narrow linewidth laser utilizing an external phase modulator driven by a pseudo-random-bit-sequence (PRBS) waveform. This ingenious optical pumping scheme can significantly enhance the signal response and suppress light shift noise, as well as can reduce the gradient of electron spin polarization and improve the stability of magnetometers. Compared with a narrow linewidth laser pumping scheme, the response of the magnetometer is increased by 56%, experimentally. The relative polarization gradient is reduced from 9.8%/cm to better than 4%/cm by setting PRBS with a bit rate of 16 GHz. This scheme can also be applied to many other fields such as noninvasive bio-magnetic imaging and atomic spin gyroscopes.
An optical pumping scheme is proposed for reducing the gradient of electron spin polarization and suppressing light source noise in a spin-exchange relaxation-free magnetometer. This is achieved by modulating only the phase of a narrow-linewidth pump light field with external Gaussian noise. Compared to the absence of phase modulation, the uniformity of electron spin polarization was improved by over 40%, and the light-frequency noise suppression ratio of the magnetometer was enhanced by 4.3 times. Additionally, the response of the magnetometer was increased by 54%, resulting in a sensitivity of 0.34 fT/Hz 1/2 at 30 Hz. The applicability of this scheme can extend to other optical pumping experiments involving large atom ensembles requiring uniform electron spin polarization distribution, which is beneficial for developing ultra-high sensitivity and high stability magnetometers essential for magneto-cardiography and magneto-encephalography research applications.
A hybrid optical pumping method employing a broad linewidth laser is proposed to enhance spin coherence and suppress virtual magnetic field noise in atomic magnetometers. The central frequency of broad linewidth laser is tuned to the resonance peak of the alkali-metal atoms D1 line. Its multiple frequency components suppress AC-Stark shift fluctuations caused by pumping laser frequency variations, thereby reducing virtual magnetic field noise. In addition, these components decrease the average optical absorption cross-section, improving the uniformity of atomic spin polarization, further enhancing spin coherence and extending transverse relaxation time. Experimental results show that, compared with narrow linewidth pumping, the proposed method suppresses virtual magnetic field noise by 17.95% to 34.50%, and increases the magnetometer response by 1.62% to 30.31% at 5 Hz. The average sensitivity within the frequency range of 1-20 Hz is improved to 0.158 fT/Hz 1/2 , representing a significant enhancement of 30.70% compared to narrow linewidth pumping.
This work proposes an optical pumping strategy based on a broadband laser to overcome the problem of atomic spin polarization gradients and sensitivity to optical frequency noise in NMR gyroscopes. A band-limited Gaussian white noise radiofrequency signal is applied to a lithium niobate electro-optic phase modulator to do this. A narrow linewidth laser maintains its frequency stability while uniformly broadening its spectrum to the hundreds of MHz range. Compared to unmodulated pumping, the proposed scheme enhances the uniformity of rubidium spin polarization by approximately 10%, reaching a measured value of 92.8%. Additionally, the sensitivity of the inert gas precession signal to optical frequency noise is reduced by half. This scheme can be extended to other atomic sensors requiring higher uniform spin polarization distributions and provides a promising way to achieve high-stability, low-noise NMR gyroscope systems.
Optically pumped atomic magnetometers are fundamentally limited by spin-exchange relaxation in finite magnetic fields. In conventional parametric resonance magnetometers (PRMs), this relaxation dominates the resonance linewidth, producing broad profiles that degrade sensitivity. Here, we suppress this relaxation by incorporating light narrowing via optical pumping into spin-stretched states in a longitudinally modulated PRM, which directly enables dual-axis vector detection of transverse magnetic fields through lock-in demodulation. Under optimized conditions, the magnetometer achieves transverse sensitivities of 210fT/Hz210\phantom{\rule{4pt}{0ex}}\mathrm{fT}/\sqrt{\mathrm{Hz}}210fT/Hz​ and 290fT/Hz290\phantom{\rule{4pt}{0ex}}\mathrm{fT}/\sqrt{\mathrm{Hz}}290fT/Hz​ along two orthogonal axes, a 3-dB bandwidth of about 500Hz500\phantom{\rule{4pt}{0ex}}\mathrm{Hz}500Hz, and excellent cross-axis discrimination---an order-of-magnitude improvement over conventional PRMs. This work demonstrates that light narrowing effectively overcomes the spin-exchange limitation in finite-field operation, providing a promising route for high-sensitivity vector magnetometry in applications such as atomic gyroscopes and active magnetic compensation.
A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.
The ultrasensitive magnetometer has a vital importance in fundamental research and applications. Currently, the spin-exchange relaxation-free (SERF) atomic magnetometer has been reported with a sensitivity around the level of fT/Hz 1/2 . To enhance the sensitivity, a gradiometer configuration has usually been introduced to cancel the common-mode noise between two separate channels. However, the signal and response from different channels are not the same due to the attenuation of the pump beam. Here, we proposed a counter-propagating optical sideband pumping method to polarize the atoms, using the electro-optic modulator to modulate the single-pump beam, generating two symmetrically red- and blue-detuned sidebands of frequency. This scheme leads to a significant reduction of undesirable effects coming along with the optical pumping, such as light shifts and spatial inhomogeneity in atomic spin polarization. With the help of this pumping scheme, the two channels have the same magnetic response, and we have built a gradiometer atomic magnetometer with a sensitivity of 0.5 fT/Hz 1/2 ranging from 5 to 40 Hz. Our results propose the possibility of creating larger arrays of atomic magnetometers (AMs) with high sensitivity and spatial resolution based on single-vapor cells for magnetocardiography and magnetoencephalography imaging or searching for exotic spin-dependent interactions.