Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Express

Imaging of high-frequency electromagnetic field by multipulse quantum sensing using nitrogen vacancy centers in diamond

Shintaro Nomura, Hideyuki Watanabe, Satoshi Kashiwaya

Published Jul 31, 2023• 4 citations
Publisher

Abstract

Abstract Near-field enhancement of the microwave field is applied for imaging high frequency radio field using a diamond chip with an n-doped isotopically purified diamond layer grown by microwave plasma-assisted chemical vapor deposition. A short π pulse length enables us to utilize a multipulse dynamic decoupling method for the detection of radio frequency field at 19.23 MHz. An extraordinary frequency resolution of the external magnetic field detection is achieved by using amplitude-shaped control pulses. Our method opens up the possibility for high-frequency-resolution RF imaging at μm spatial resolution using nitrogen vacancy centers in diamond.

DOI
10.35848/1882-0786/acec2f

Related papers

High-Resolution Quantum Sensing with Shaped Control Pulses

Jonathan Zopes, Kento Sasaki, K. S. Cujia +5 more

We investigate the application of amplitude-shaped control pulses for enhancing the time and frequency resolution of multipulse quantum sensing sequences. Using the electronic spin of a single nitrogen-vacancy center in diamond and up to 10 000 coherent microwave pulses with a cosine square envelope, we demonstrate 0.6-ps timing resolution for the interpulse delay. This represents a refinement by over 3 orders of magnitude compared to the 2-ns hardware sampling. We apply the method for the detection of external ac magnetic fields and nuclear magnetic resonance signals of ^{13}C spins with high spectral resolution. Our method is simple to implement and especially useful for quantum applications that require fast phase gates, many control pulses, and high fidelity.

arXiv:1705.07968•Physical Review Letters•Dec 28, 2017•36 citations

High-frequency resolution diamond nitrogen-vacancy center wide-spectrum imaging technology

Yuanyuan Shen, Bo Wang, Dongqian Ke +10 more

High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.

Acta Physica Sinica•Jan 1, 2024•0 citations

Wide bandwidth instantaneous radio frequency spectrum analyzer based on nitrogen vacancy centers in diamond

Mayeul Chipaux, Loïc Toraille, C. Larat +4 more

We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz, associated to a frequency resolution of 7 MHz , and a refresh rate of 4 ms. With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz, only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs.

arXiv:1509.01395•Applied Physics Letters•Dec 7, 2015•58 citations

Demonstration of highly sensitive wideband microwave sensing using ensemble nitrogen-vacancy centers

Kensuke Ogawa, Shunsuke Nishimura, Kento Sasaki +1 more

Microwave magnetometry is essential for the advancement of microwave technologies. We demonstrate a broadband microwave sensing protocol using the AC Zeeman effect with ensemble nitrogen-vacancy (NV) centers in diamond. A widefield microscope can visualize the frequency characteristics of the microwave resonator and the spatial distribution of off-resonant microwave amplitude. Furthermore, by combining this method with dynamical decoupling, we achieve the microwave amplitude sensitivity of 5.2 μT/Hz, which is 7.7 times better than 40.2 μT/Hz obtained using the protocol in previous research over a sensing volume of 2.77 μm×2.77 μm×30 nm. Our achievement is a concrete step in adapting ensemble NV centers for wideband and widefield microwave imaging.

arXiv:2311.15196•Applied Physics Letters•Nov 20, 2023•7 citations

Imaging of microwave magnetic field orientation using continuous-wave experiments on nitrogen-vacancy centers in diamond

Akshat Rana, Pooja Lamba, Atanu Ghosh +2 more

Abstract Imaging of microwave magnetic fields with nano-scale resolution has interesting applications. Specifically, detecting the orientation of microwave fields is useful in condensed matter physics and quantum control. However, most of the existing methods for microwave field imaging are limited to detecting the magnitude of the fields. Due to their small sensor size and favorable optical and spin properties, nitrogen-vacancy (NV) centers in diamond are highly suitable for imaging dc and ac magnetic fields. The reported methods for detecting the direction of microwave magnetic fields use pulsed Rabi frequency measurements. Here, we demonstrate imaging of the direction of linearly polarized microwave magnetic fields using only continuous-wave experiments on NV centers. This simplifies the sensor apparatus and is particularly advantageous in applications where pulsing of the target microwave field is not possible. The method requires a static bias magnetic field oriented perpendicular to the quantization axis of NV centers. We detect the direction of an arbitrary microwave magnetic field using NV centers of two different orientations of an NV ensemble. Moreover, we demonstrate that the projection of the microwave fields onto a plane can be imaged using NV centers of a single orientation. This can be straightforwardly implemented using a single NV center.

arXiv:2506.17695•Journal of Physics D Applied Physics•Oct 9, 2025•0 citations

Frequency-tunable magnetic field sensing using continuous-wave optically detected magnetic resonance with nitrogen-vacancy centers in diamond

Ryusei Okaniwa, Takumi Mikawa, Yuichiro Matsuzaki +8 more

The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetometry using continuous-wave optically detected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF)-dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with RF fields at two different frequencies. One creates the RF-dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF-dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on the RF field with a single frequency. The estimated bandwidth is 7.5 MHz, higher than that of the conventional method using the RF-dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.

arXiv:2305.12141•Journal of Applied Physics•Jan 22, 2024•7 citations
Abstract Near-field enhancement of the microwave field is applied for imaging high frequency radio field using a diamond chip with an n-doped isotopically purified diamond layer grown by microwave plasma-assisted chemical vapor deposition. A short π pulse length enables us to utilize a multipulse dynamic decoupling method for the detection of radio frequency field at 19.23 MHz. An extraordinary frequency resolution of the external magnetic field detection is achieved by using amplitude-shaped control pulses. Our method opens up the possibility for high-frequency-resolution RF imaging at μm spatial resolution using nitrogen vacancy centers in diamond.
We investigate the application of amplitude-shaped control pulses for enhancing the time and frequency resolution of multipulse quantum sensing sequences. Using the electronic spin of a single nitrogen-vacancy center in diamond and up to 10 000 coherent microwave pulses with a cosine square envelope, we demonstrate 0.6-ps timing resolution for the interpulse delay. This represents a refinement by over 3 orders of magnitude compared to the 2-ns hardware sampling. We apply the method for the detection of external ac magnetic fields and nuclear magnetic resonance signals of ^{13}C spins with high spectral resolution. Our method is simple to implement and especially useful for quantum applications that require fast phase gates, many control pulses, and high fidelity.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz, associated to a frequency resolution of 7 MHz , and a refresh rate of 4 ms. With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz, only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs.
Microwave magnetometry is essential for the advancement of microwave technologies. We demonstrate a broadband microwave sensing protocol using the AC Zeeman effect with ensemble nitrogen-vacancy (NV) centers in diamond. A widefield microscope can visualize the frequency characteristics of the microwave resonator and the spatial distribution of off-resonant microwave amplitude. Furthermore, by combining this method with dynamical decoupling, we achieve the microwave amplitude sensitivity of 5.2 μT/Hz, which is 7.7 times better than 40.2 μT/Hz obtained using the protocol in previous research over a sensing volume of 2.77 μm×2.77 μm×30 nm. Our achievement is a concrete step in adapting ensemble NV centers for wideband and widefield microwave imaging.
Abstract Imaging of microwave magnetic fields with nano-scale resolution has interesting applications. Specifically, detecting the orientation of microwave fields is useful in condensed matter physics and quantum control. However, most of the existing methods for microwave field imaging are limited to detecting the magnitude of the fields. Due to their small sensor size and favorable optical and spin properties, nitrogen-vacancy (NV) centers in diamond are highly suitable for imaging dc and ac magnetic fields. The reported methods for detecting the direction of microwave magnetic fields use pulsed Rabi frequency measurements. Here, we demonstrate imaging of the direction of linearly polarized microwave magnetic fields using only continuous-wave experiments on NV centers. This simplifies the sensor apparatus and is particularly advantageous in applications where pulsing of the target microwave field is not possible. The method requires a static bias magnetic field oriented perpendicular to the quantization axis of NV centers. We detect the direction of an arbitrary microwave magnetic field using NV centers of two different orientations of an NV ensemble. Moreover, we demonstrate that the projection of the microwave fields onto a plane can be imaged using NV centers of a single orientation. This can be straightforwardly implemented using a single NV center.
The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetometry using continuous-wave optically detected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF)-dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with RF fields at two different frequencies. One creates the RF-dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF-dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on the RF field with a single frequency. The estimated bandwidth is 7.5 MHz, higher than that of the conventional method using the RF-dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.