Microwave magnetometry is essential for the advancement of microwave technologies. We demonstrate a broadband microwave sensing protocol using the AC Zeeman effect with ensemble nitrogen-vacancy (NV) centers in diamond. A widefield microscope can visualize the frequency characteristics of the microwave resonator and the spatial distribution of off-resonant microwave amplitude. Furthermore, by combining this method with dynamical decoupling, we achieve the microwave amplitude sensitivity of 5.2 μT/Hz, which is 7.7 times better than 40.2 μT/Hz obtained using the protocol in previous research over a sensing volume of 2.77 μm×2.77 μm×30 nm. Our achievement is a concrete step in adapting ensemble NV centers for wideband and widefield microwave imaging.
Microwave magnetometry is essential for the advancement of microwave technologies. We demonstrate a broadband microwave sensing protocol using the AC Zeeman effect with ensemble nitrogen-vacancy (NV) centers in diamond. A widefield microscope can visualize the frequency characteristics of the microwave resonator and the spatial distribution of off-resonant microwave amplitude. Furthermore, by combining this method with dynamical decoupling, we achieve the microwave amplitude sensitivity of 5.2 μT/Hz, which is 7.7 times better than 40.2 μT/Hz obtained using the protocol in previous research over a sensing volume of 2.77 μm×2.77 μm×30 nm. Our achievement is a concrete step in adapting ensemble NV centers for wideband and widefield microwave imaging.
Microwave magnetometry is essential to a variety of modern electronic techniques, most notably integrated circuits. The nitrogen-vacancy center in diamond has shown the ability of nanoscale resolution for the microwave magnetic field measurement and imaging. However, the characterization of the wideband magnetic field remains a challenge. Here we experimentally demonstrated a wideband microwave magnetometry with an off-resonance protocol based on the Bloch-Siegert shift effect. The off-resonance microwave magnetic field shifts the energy level of the nitrogen-vacancy center. It results in a phase accumulation during the evolution of the superposition state of the quantum sensor. According to this effect, by optimizing the evolution time, we experimentally verified the bandwidth widening of an order of magnitude compared with the Rabi oscillation, i.e., on-resonance method with an acceptable decrease of the sensitivity. In addition, we extracted the microwave frequency with a two-qubit system, which consists of a nitrogen-vacancy center and a nearby 13C nucleus. This approach enables the building of a wideband and potentially nanoscale microwave magnetometry to allow various potential applications, such as electronic circuits development.
The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about 1.2 nT/Hz. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in a diamond is limited by a number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve a highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4 × 10−3 mm3. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers. This system combined with a decoupling pulse sequence, XY16, extends the spin coherence time (T2) up to 27 times longer than that with a spin echo method. Consequently, we obtained an AC magnetic field sensitivity of 10.8 pt/Hz using the dynamical decoupling pulse sequence.
We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz, associated to a frequency resolution of 7 MHz , and a refresh rate of 4 ms. With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz, only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs.
An ensemble of nitrogen-vacancy (NV) centers in diamond is a fascinating candidate for realizing a sensitive magnetic field sensor. In particular, since the axes of the NV centers are distributed along four directions, a collection of measurement data from NV centers with different axes provides information on the vector components of a magnetic field. However, in the conventional approach, the low measurement contrast of NV centers limits the sensitivity of vector magnetic field sensing. Recently, to overcome this problem, multi-frequency control of the NV centers has been proposed. The key idea is that four types of NV centers with different axes are simultaneously controlled by multi-frequency microwave pulses. Here, we demonstrate vector magnetic field sensing with an ensemble of NV centers in diamond via such multi-frequency control with pulsed-type measurements. We use Hahn echo pulses and extract information on the vector components of an applied AC magnetic field. We find that the sensitivity of the vector field sensing with multi-frequency control is better than that with single-frequency control for every vector component of a magnetic field.