Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Frequency-Dependent Squeezed Vacuum Source for the Advanced Virgo Gravitational-Wave Detector

F. Acernese, M. Agathos, A. Ain, Simone Albanesi, C Alléné, A. Allocca, A. Amato, Claude Amra, M. Andia, T Andrade, Nicolás Andrés, Marc Andrés-Carcasona, T. Andrić, Stefano Ansoldi, S. Antier, Theocharis A. Apostolatos, E. Z. Appavuravther, M. Arène, N. Arnaud, M. Assiduo, S. Assis de Souza Melo, P. Astone, F. Aubin, S. Babak, F. Badaracco, S. Bagnasco, J. Baird, Tomasz Baka, Giulio Ballardin, G. Baltus, B. Banerjee, P. Barneo, F. Barone, M. Barsuglia, D. Barta, A. Basti, M. Bawaj, M. Bazzan, F. Beirnaert, M. Bejger, V. Benedetto, M. Berbel, Sebastiano Bernuzzi, D. Bersanetti, Alessandro Bertolini, U. Bhardwaj, A. Bianchi, Maciej Bilicki, S. Bini, M. Bischi, M. Bitossi, M. A. Bizouard, F. Bobba, M. Boër, G. Bogaert, Guillaume Boileau, Mattia Boldrini, L. D. Bonavena, R. Bondarescu, F. Bondu, Romain Bonnand, Valerio Boschi, V. Boudart, Y. Bouffanais, A. Bozzi, C. Bradaschia, Matteo Braglia, M. Branchesi, M. Breschi, Tristan Briant, Alain Brillet, J. Brooks, Giuseppe Eugenio Bruno, F. Bucci, Oleg M Bulashenko, T. Bulik, Henk Jan Bulten, R. Buscicchio, Damir Buskulic, C. Buy, G. Cabras, Ricardo Cabrita, Gianpietro Cagnoli C, Enrico Calloni, M. Canepa, G. Caneva Santoro, M. Cannavacciuolo, E. Capocasa, Giovanni Carapella, Franco Carbognani, M. Carpinelli, G. Carullo, J. Casanueva Diaz, C. Casentini, S. Caudill, R. Cavalieri, G. Cella, Pablo Cerdá-Durán, E. Cesarini, Walid Chaibi

Published Jul 25, 2023• 41 citations
Publisher

Abstract

In this Letter, we present the design and performance of the frequency-dependent squeezed vacuum source that will be used for the broadband quantum noise reduction of the Advanced Virgo Plus gravitational-wave detector in the upcoming observation run. The frequency-dependent squeezed field is generated by a phase rotation of a frequency-independent squeezed state through a 285 m long, high-finesse, near-detuned optical resonator. With about 8.5 dB of generated squeezing, up to 5.6 dB of quantum noise suppression has been measured at high frequency while close to the filter cavity resonance frequency, the intracavity losses limit this value to about 2 dB. Frequency-dependent squeezing is produced with a rotation frequency stability of about 6 Hz rms, which is maintained over the long term. The achieved results fulfill the frequency dependent squeezed vacuum source requirements for Advanced Virgo Plus. With the current squeezing source, considering also the estimated squeezing degradation induced by the interferometer, we expect a reduction of the quantum shot noise and radiation pressure noise of up to 4.5 dB and 2 dB, respectively.

DOI
10.1103/physrevlett.131.041403

Related papers

Broadband quantum noise reduction via frequency dependent squeezing for Advanced Virgo Plus

E. Polini

Abstract Quantum noise is limiting the sensitivity of ground based gravitational wave detectors both at high frequency, in the form of shot noise, and low frequency, in the form of radiation pressure noise. In the last observing run, the injection of frequency independent squeezing improved Virgo and LIGO sensitivities at high frequency, slightly worsening the performance at low frequency. A broadband quantum noise reduction can be achieved using frequency dependent squeezing, i. e. rotating the vacuum squeezed ellipse below 100 Hz by reflecting the squeezed vacuum off a Fabry–Perot cavity, called filter cavity. The frequency-dependent squeezed quadrature rotation with rotation frequency around a few tens of Hz has been proven at National Astronomical Observatory of Japan (NAOJ) and at Massachusetts Institute of Technology (MIT). The experiment at NAOJ uses the former TAMA facility, a 300 meter long filter cavity, reproducing in scale the ones planned to be installed in Virgo and LIGO. Once the frequency dependent squeezing is produced, it has to be injected into the interferometer. This interface is not trivial, since it requires the installation of additional benches and a 285 meter long cavity (in Advanced Virgo Plus) and also to couple the rotating squeezed vacuum with the detector. An important issue which can worsen the performance of frequency dependent squeezing or directly the interferometer sensitivity is the stray light. To avoid the propagation of additional stray light, we traced the ghost beam on squeezing benches, inside linking tubes and inside the filter cavity and several diaphragms and baffles will be installed to limit this problem.

Physica Scripta•May 7, 2021•1 citation

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

Yang Zhao, N. Aritomi, E. Capocasa +20 more

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

arXiv:2003.10672•Physical Review Letters•Apr 28, 2020•104 citations

Frequency-Dependent Squeezing for Advanced LIGO

Lee P. McCuller, Chris Whittle, D. Ganapathy +13 more

The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."

arXiv:2003.13443•Physical Review Letters•Apr 28, 2020•173 citations

Quantum noise reduction in Advanced Virgo

V. Sequino

Abstract In order to detect the small distance variations induced by gravitational waves, very sensitive devices must be used. Gravitational wave detectors are sophisticated interferometers sensitive even to vacuum fluctuations. These latter are responsible for quantum noise. Due to the frequency-dependent response of gravitational wave interferometers, quantum noise manifests itself as radiation pressure noise for frequencies below 100 Hz, while as shot noise for higher frequencies. The solution that has been adopted in order to reduce quantum noise is the injection, through the interferometer output port, of vacuum states, called squeezed, whose amplitude and phase uncertainties are correlated. A frequency-independent squeezing technique, as a method for the reduction of the quantum noise, has been already demonstrated in long-arm interferometers. Radiation pressure noise does not limit the sensitivity of the present interferometers, being this completely covered by other noises. But, in the near future, these noises will be reduced and also this quantum noise component will be relevant. The adopted solution to have a broad-band quantum noise reduction is a frequency-dependent squeezing technique. In this paper the results obtained in Advanced Virgo using the frequency-independent squeezing technique will be shown. Moreover the conceptual design for the implementation of the frequency-dependent squeezing will be presented.

Physica Scripta•Jun 21, 2021•5 citations

Use of squeezed vacuum states to reduce the quantum noise of the Advanced Virgo gravitational wave detector

M. Eisenmann

Current gravitational wave detectors, such as LIGO, Virgo and KAGRA, are laser interferometers. This technique consists of injecting a laser beam through an input port, which is then separated into two arms several kilometers long by a semi-reflecting mirror. At the end of each arm, a mirror reflects thebeam back to the semi-reflecting mirror. The two beams then interfere and the power of the resulting beam, measured at the detection port, contains information about the relative length of the two arms. When a gravitational wave passes through the detector, this relative length varies in time. Several noise sources degrade the quality of the recorded signal, which affects the number of gravitational waves that can be observed. Currently, this sensitivity is limited at high-frequency by the quantum noise.An electromagnetic wave described by quantum mechanics has a classical amplitude and quantum fluctuations in amplitude and phase. A state with a null classical amplitude is called a vacuum state, but still has these quantum fluctuations. Thus, in the detector, although no light beam is introduced through the detection port, the vacuum state is present. It is then the quantum fluctuations of this vacuum state that are responsible for the quantum noise of the interferometer. In particular, the phase and amplitude fluctuations are respectively responsible for the quantum noise at high and low frequencies; the separation between these two regions occurs at about 100 Hz.The work presented in this thesis focuses on the injection of squeezed vacuum states into the Virgo detector via the detection port in order to lower the quantum noise. These states are characterized by the fact that their phase (amplitude) fluctuations are reduced, which allows reducing the quantum noise at high (low) frequency. As the Virgo detector is currently limited only by high-frequency quantum noise, only phase squeezed vacuum states were used during the last observation period O3. It was first necessary to ensure that these squeezed vacuum states had the proper geometric and phase parameters with respect to the interferometer beam such that they were not degraded. Control loops allowed these parameters to be maintained at their nominal values during O3, a year long period. The decrease in high-frequency quantum noise, but also the increase in low-frequency quantum noise, have been measured for the first time with the Virgo detector. These observations were in agreement with the measurements of the losses that affect the squeezed vacuum states.From O4 , quantum noise will also be limiting at low frequency. It will then be possible to use squeezed vacuum states having their amplitude fluctuations reduced at low frequency and their phase fluctuations reduced at high frequency. Thus, the total quantum noise can be reduced. Such states can be generated using an optical cavity called a filter cavity. The second part of the work presented in this thesis consisted in defining the optical parameters of the filter cavity that will be installed on Virgo for O4. To do this, it was first necessary to study the sources of degradation of the squeezed states of the vacuum. This then allowed defining the length of the filtering cavity and the set of parameters of the mirrors that compose it. Finally, the implementation of this filter cavity within the Virgo infrastructure was studied. This has shown that the use of compressed states will effectively reduce quantum noise over the entire sensitivity spectrum of Virgo.

•Nov 10, 2020•0 citations

Use of squeezed states of light for the reduction of quantum noise in Advanced Virgo

M. Eisenmann

Current gravitational wave detectors, such as LIGO, Virgo and KAGRA, are laser interferometers. This technique consists of injecting a laser beam through an input port, which is then separated into two arms several kilometers long by a semi-reflecting mirror. At the end of each arm, a mirror reflects the beam back to the semi-reflecting mirror. The two beams then interfere and the power of the resulting beam, measured at the detection port, contains information about the relative length of the two arms. When a gravitational wave passes through the detector, this relative length varies in time. Several noise sources degrade the quality of the recorded signal, which affects the number of gravitational waves that can be observed. Currently, this sensitivity is limited at high-frequency by the quantum noise.An electromagnetic wave described by quantum mechanics has a classical amplitude and quantum fluctuations in amplitude and phase. A state with a null classical amplitude is called a vacuum state, but still has these quantum fluctuations. Thus, in the detector, although no light beam is introduced through the detection port, the vacuum state is present. It is then the quantum fluctuations of this vacuum state that are responsible for the quantum noise of the interferometer. In particular, the phase and amplitude fluctuations are respectively responsible for the quantum noise at high and low frequencies; the separation between these two regions occurs at about 100 Hz.The work presented in this thesis focuses on the injection of squeezed vacuum states into the Virgo detector via the detection port in order to lower the quantum noise. These states are characterized by the fact that their phase (amplitude) fluctuations are reduced, which allows reducing the quantum noise at high (low) frequency. As the Virgo detector is currently limited only by high-frequency quantum noise, only phase squeezed vacuum states were used during the last observation period O3. It was first necessary to ensure that these squeezed vacuum states had the proper geometric and phase parameters with respect to the interferometer beam such that they were not degraded. Control loops allowed these parameters to be maintained at their nominal values during O3, a year long period. The decrease in high-frequency quantum noise, but also the increase in low-frequency quantum noise, have been measured for the first time with the Virgo detector. These observations were in agreement with the measurements of the losses that affect the squeezed vacuum states.From O4 , quantum noise will also be limiting at low frequency. It will then be possible to use squeezed vacuum states having their amplitude fluctuations reduced at low frequency and their phase fluctuations reduced at high frequency. Thus, the total quantum noise can be reduced. Such states can be generated using an optical cavity called a filter cavity. The second part of the work presented in this thesis consisted in defining the optical parameters of the filter cavity that will be installed on Virgo for O4. To do this, it was first necessary to study the sources of degradation of the squeezed states of the vacuum. This then allowed defining the length of the filtering cavity and the set of parameters of the mirrors that compose it. Finally, the implementation of this filter cavity within the Virgo infrastructure was studied. This has shown that the use of compressed states will effectively reduce quantum noise over the entire sensitivity spectrum of Virgo.

•Nov 10, 2020•0 citations
In this Letter, we present the design and performance of the frequency-dependent squeezed vacuum source that will be used for the broadband quantum noise reduction of the Advanced Virgo Plus gravitational-wave detector in the upcoming observation run. The frequency-dependent squeezed field is generated by a phase rotation of a frequency-independent squeezed state through a 285 m long, high-finesse, near-detuned optical resonator. With about 8.5 dB of generated squeezing, up to 5.6 dB of quantum noise suppression has been measured at high frequency while close to the filter cavity resonance frequency, the intracavity losses limit this value to about 2 dB. Frequency-dependent squeezing is produced with a rotation frequency stability of about 6 Hz rms, which is maintained over the long term. The achieved results fulfill the frequency dependent squeezed vacuum source requirements for Advanced Virgo Plus. With the current squeezing source, considering also the estimated squeezing degradation induced by the interferometer, we expect a reduction of the quantum shot noise and radiation pressure noise of up to 4.5 dB and 2 dB, respectively.
Abstract Quantum noise is limiting the sensitivity of ground based gravitational wave detectors both at high frequency, in the form of shot noise, and low frequency, in the form of radiation pressure noise. In the last observing run, the injection of frequency independent squeezing improved Virgo and LIGO sensitivities at high frequency, slightly worsening the performance at low frequency. A broadband quantum noise reduction can be achieved using frequency dependent squeezing, i. e. rotating the vacuum squeezed ellipse below 100 Hz by reflecting the squeezed vacuum off a Fabry–Perot cavity, called filter cavity. The frequency-dependent squeezed quadrature rotation with rotation frequency around a few tens of Hz has been proven at National Astronomical Observatory of Japan (NAOJ) and at Massachusetts Institute of Technology (MIT). The experiment at NAOJ uses the former TAMA facility, a 300 meter long filter cavity, reproducing in scale the ones planned to be installed in Virgo and LIGO. Once the frequency dependent squeezing is produced, it has to be injected into the interferometer. This interface is not trivial, since it requires the installation of additional benches and a 285 meter long cavity (in Advanced Virgo Plus) and also to couple the rotating squeezed vacuum with the detector. An important issue which can worsen the performance of frequency dependent squeezing or directly the interferometer sensitivity is the stray light. To avoid the propagation of additional stray light, we traced the ghost beam on squeezing benches, inside linking tubes and inside the filter cavity and several diaphragms and baffles will be installed to limit this problem.
The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.
The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
Abstract In order to detect the small distance variations induced by gravitational waves, very sensitive devices must be used. Gravitational wave detectors are sophisticated interferometers sensitive even to vacuum fluctuations. These latter are responsible for quantum noise. Due to the frequency-dependent response of gravitational wave interferometers, quantum noise manifests itself as radiation pressure noise for frequencies below 100 Hz, while as shot noise for higher frequencies. The solution that has been adopted in order to reduce quantum noise is the injection, through the interferometer output port, of vacuum states, called squeezed, whose amplitude and phase uncertainties are correlated. A frequency-independent squeezing technique, as a method for the reduction of the quantum noise, has been already demonstrated in long-arm interferometers. Radiation pressure noise does not limit the sensitivity of the present interferometers, being this completely covered by other noises. But, in the near future, these noises will be reduced and also this quantum noise component will be relevant. The adopted solution to have a broad-band quantum noise reduction is a frequency-dependent squeezing technique. In this paper the results obtained in Advanced Virgo using the frequency-independent squeezing technique will be shown. Moreover the conceptual design for the implementation of the frequency-dependent squeezing will be presented.
Current gravitational wave detectors, such as LIGO, Virgo and KAGRA, are laser interferometers. This technique consists of injecting a laser beam through an input port, which is then separated into two arms several kilometers long by a semi-reflecting mirror. At the end of each arm, a mirror reflects thebeam back to the semi-reflecting mirror. The two beams then interfere and the power of the resulting beam, measured at the detection port, contains information about the relative length of the two arms. When a gravitational wave passes through the detector, this relative length varies in time. Several noise sources degrade the quality of the recorded signal, which affects the number of gravitational waves that can be observed. Currently, this sensitivity is limited at high-frequency by the quantum noise.An electromagnetic wave described by quantum mechanics has a classical amplitude and quantum fluctuations in amplitude and phase. A state with a null classical amplitude is called a vacuum state, but still has these quantum fluctuations. Thus, in the detector, although no light beam is introduced through the detection port, the vacuum state is present. It is then the quantum fluctuations of this vacuum state that are responsible for the quantum noise of the interferometer. In particular, the phase and amplitude fluctuations are respectively responsible for the quantum noise at high and low frequencies; the separation between these two regions occurs at about 100 Hz.The work presented in this thesis focuses on the injection of squeezed vacuum states into the Virgo detector via the detection port in order to lower the quantum noise. These states are characterized by the fact that their phase (amplitude) fluctuations are reduced, which allows reducing the quantum noise at high (low) frequency. As the Virgo detector is currently limited only by high-frequency quantum noise, only phase squeezed vacuum states were used during the last observation period O3. It was first necessary to ensure that these squeezed vacuum states had the proper geometric and phase parameters with respect to the interferometer beam such that they were not degraded. Control loops allowed these parameters to be maintained at their nominal values during O3, a year long period. The decrease in high-frequency quantum noise, but also the increase in low-frequency quantum noise, have been measured for the first time with the Virgo detector. These observations were in agreement with the measurements of the losses that affect the squeezed vacuum states.From O4 , quantum noise will also be limiting at low frequency. It will then be possible to use squeezed vacuum states having their amplitude fluctuations reduced at low frequency and their phase fluctuations reduced at high frequency. Thus, the total quantum noise can be reduced. Such states can be generated using an optical cavity called a filter cavity. The second part of the work presented in this thesis consisted in defining the optical parameters of the filter cavity that will be installed on Virgo for O4. To do this, it was first necessary to study the sources of degradation of the squeezed states of the vacuum. This then allowed defining the length of the filtering cavity and the set of parameters of the mirrors that compose it. Finally, the implementation of this filter cavity within the Virgo infrastructure was studied. This has shown that the use of compressed states will effectively reduce quantum noise over the entire sensitivity spectrum of Virgo.
Current gravitational wave detectors, such as LIGO, Virgo and KAGRA, are laser interferometers. This technique consists of injecting a laser beam through an input port, which is then separated into two arms several kilometers long by a semi-reflecting mirror. At the end of each arm, a mirror reflects the beam back to the semi-reflecting mirror. The two beams then interfere and the power of the resulting beam, measured at the detection port, contains information about the relative length of the two arms. When a gravitational wave passes through the detector, this relative length varies in time. Several noise sources degrade the quality of the recorded signal, which affects the number of gravitational waves that can be observed. Currently, this sensitivity is limited at high-frequency by the quantum noise.An electromagnetic wave described by quantum mechanics has a classical amplitude and quantum fluctuations in amplitude and phase. A state with a null classical amplitude is called a vacuum state, but still has these quantum fluctuations. Thus, in the detector, although no light beam is introduced through the detection port, the vacuum state is present. It is then the quantum fluctuations of this vacuum state that are responsible for the quantum noise of the interferometer. In particular, the phase and amplitude fluctuations are respectively responsible for the quantum noise at high and low frequencies; the separation between these two regions occurs at about 100 Hz.The work presented in this thesis focuses on the injection of squeezed vacuum states into the Virgo detector via the detection port in order to lower the quantum noise. These states are characterized by the fact that their phase (amplitude) fluctuations are reduced, which allows reducing the quantum noise at high (low) frequency. As the Virgo detector is currently limited only by high-frequency quantum noise, only phase squeezed vacuum states were used during the last observation period O3. It was first necessary to ensure that these squeezed vacuum states had the proper geometric and phase parameters with respect to the interferometer beam such that they were not degraded. Control loops allowed these parameters to be maintained at their nominal values during O3, a year long period. The decrease in high-frequency quantum noise, but also the increase in low-frequency quantum noise, have been measured for the first time with the Virgo detector. These observations were in agreement with the measurements of the losses that affect the squeezed vacuum states.From O4 , quantum noise will also be limiting at low frequency. It will then be possible to use squeezed vacuum states having their amplitude fluctuations reduced at low frequency and their phase fluctuations reduced at high frequency. Thus, the total quantum noise can be reduced. Such states can be generated using an optical cavity called a filter cavity. The second part of the work presented in this thesis consisted in defining the optical parameters of the filter cavity that will be installed on Virgo for O4. To do this, it was first necessary to study the sources of degradation of the squeezed states of the vacuum. This then allowed defining the length of the filtering cavity and the set of parameters of the mirrors that compose it. Finally, the implementation of this filter cavity within the Virgo infrastructure was studied. This has shown that the use of compressed states will effectively reduce quantum noise over the entire sensitivity spectrum of Virgo.