Current gravitational wave detectors, such as LIGO, Virgo and KAGRA, are laser interferometers. This technique consists of injecting a laser beam through an input port, which is then separated into two arms several kilometers long by a semi-reflecting mirror. At the end of each arm, a mirror reflects thebeam back to the semi-reflecting mirror. The two beams then interfere and the power of the resulting beam, measured at the detection port, contains information about the relative length of the two arms. When a gravitational wave passes through the detector, this relative length varies in time. Several noise sources degrade the quality of the recorded signal, which affects the number of gravitational waves that can be observed. Currently, this sensitivity is limited at high-frequency by the quantum noise.An electromagnetic wave described by quantum mechanics has a classical amplitude and quantum fluctuations in amplitude and phase. A state with a null classical amplitude is called a vacuum state, but still has these quantum fluctuations. Thus, in the detector, although no light beam is introduced through the detection port, the vacuum state is present. It is then the quantum fluctuations of this vacuum state that are responsible for the quantum noise of the interferometer. In particular, the phase and amplitude fluctuations are respectively responsible for the quantum noise at high and low frequencies; the separation between these two regions occurs at about 100 Hz.The work presented in this thesis focuses on the injection of squeezed vacuum states into the Virgo detector via the detection port in order to lower the quantum noise. These states are characterized by the fact that their phase (amplitude) fluctuations are reduced, which allows reducing the quantum noise at high (low) frequency. As the Virgo detector is currently limited only by high-frequency quantum noise, only phase squeezed vacuum states were used during the last observation period O3. It was first necessary to ensure that these squeezed vacuum states had the proper geometric and phase parameters with respect to the interferometer beam such that they were not degraded. Control loops allowed these parameters to be maintained at their nominal values during O3, a year long period. The decrease in high-frequency quantum noise, but also the increase in low-frequency quantum noise, have been measured for the first time with the Virgo detector. These observations were in agreement with the measurements of the losses that affect the squeezed vacuum states.From O4 , quantum noise will also be limiting at low frequency. It will then be possible to use squeezed vacuum states having their amplitude fluctuations reduced at low frequency and their phase fluctuations reduced at high frequency. Thus, the total quantum noise can be reduced. Such states can be generated using an optical cavity called a filter cavity. The second part of the work presented in this thesis consisted in defining the optical parameters of the filter cavity that will be installed on Virgo for O4. To do this, it was first necessary to study the sources of degradation of the squeezed states of the vacuum. This then allowed defining the length of the filtering cavity and the set of parameters of the mirrors that compose it. Finally, the implementation of this filter cavity within the Virgo infrastructure was studied. This has shown that the use of compressed states will effectively reduce quantum noise over the entire sensitivity spectrum of Virgo.
Current gravitational wave detectors, such as LIGO, Virgo and KAGRA, are laser interferometers. This technique consists of injecting a laser beam through an input port, which is then separated into two arms several kilometers long by a semi-reflecting mirror. At the end of each arm, a mirror reflects thebeam back to the semi-reflecting mirror. The two beams then interfere and the power of the resulting beam, measured at the detection port, contains information about the relative length of the two arms. When a gravitational wave passes through the detector, this relative length varies in time. Several noise sources degrade the quality of the recorded signal, which affects the number of gravitational waves that can be observed. Currently, this sensitivity is limited at high-frequency by the quantum noise.An electromagnetic wave described by quantum mechanics has a classical amplitude and quantum fluctuations in amplitude and phase. A state with a null classical amplitude is called a vacuum state, but still has these quantum fluctuations. Thus, in the detector, although no light beam is introduced through the detection port, the vacuum state is present. It is then the quantum fluctuations of this vacuum state that are responsible for the quantum noise of the interferometer. In particular, the phase and amplitude fluctuations are respectively responsible for the quantum noise at high and low frequencies; the separation between these two regions occurs at about 100 Hz.The work presented in this thesis focuses on the injection of squeezed vacuum states into the Virgo detector via the detection port in order to lower the quantum noise. These states are characterized by the fact that their phase (amplitude) fluctuations are reduced, which allows reducing the quantum noise at high (low) frequency. As the Virgo detector is currently limited only by high-frequency quantum noise, only phase squeezed vacuum states were used during the last observation period O3. It was first necessary to ensure that these squeezed vacuum states had the proper geometric and phase parameters with respect to the interferometer beam such that they were not degraded. Control loops allowed these parameters to be maintained at their nominal values during O3, a year long period. The decrease in high-frequency quantum noise, but also the increase in low-frequency quantum noise, have been measured for the first time with the Virgo detector. These observations were in agreement with the measurements of the losses that affect the squeezed vacuum states.From O4 , quantum noise will also be limiting at low frequency. It will then be possible to use squeezed vacuum states having their amplitude fluctuations reduced at low frequency and their phase fluctuations reduced at high frequency. Thus, the total quantum noise can be reduced. Such states can be generated using an optical cavity called a filter cavity. The second part of the work presented in this thesis consisted in defining the optical parameters of the filter cavity that will be installed on Virgo for O4. To do this, it was first necessary to study the sources of degradation of the squeezed states of the vacuum. This then allowed defining the length of the filtering cavity and the set of parameters of the mirrors that compose it. Finally, the implementation of this filter cavity within the Virgo infrastructure was studied. This has shown that the use of compressed states will effectively reduce quantum noise over the entire sensitivity spectrum of Virgo.
Current gravitational wave detectors, such as LIGO, Virgo and KAGRA, are laser interferometers. This technique consists of injecting a laser beam through an input port, which is then separated into two arms several kilometers long by a semi-reflecting mirror. At the end of each arm, a mirror reflects the beam back to the semi-reflecting mirror. The two beams then interfere and the power of the resulting beam, measured at the detection port, contains information about the relative length of the two arms. When a gravitational wave passes through the detector, this relative length varies in time. Several noise sources degrade the quality of the recorded signal, which affects the number of gravitational waves that can be observed. Currently, this sensitivity is limited at high-frequency by the quantum noise.An electromagnetic wave described by quantum mechanics has a classical amplitude and quantum fluctuations in amplitude and phase. A state with a null classical amplitude is called a vacuum state, but still has these quantum fluctuations. Thus, in the detector, although no light beam is introduced through the detection port, the vacuum state is present. It is then the quantum fluctuations of this vacuum state that are responsible for the quantum noise of the interferometer. In particular, the phase and amplitude fluctuations are respectively responsible for the quantum noise at high and low frequencies; the separation between these two regions occurs at about 100 Hz.The work presented in this thesis focuses on the injection of squeezed vacuum states into the Virgo detector via the detection port in order to lower the quantum noise. These states are characterized by the fact that their phase (amplitude) fluctuations are reduced, which allows reducing the quantum noise at high (low) frequency. As the Virgo detector is currently limited only by high-frequency quantum noise, only phase squeezed vacuum states were used during the last observation period O3. It was first necessary to ensure that these squeezed vacuum states had the proper geometric and phase parameters with respect to the interferometer beam such that they were not degraded. Control loops allowed these parameters to be maintained at their nominal values during O3, a year long period. The decrease in high-frequency quantum noise, but also the increase in low-frequency quantum noise, have been measured for the first time with the Virgo detector. These observations were in agreement with the measurements of the losses that affect the squeezed vacuum states.From O4 , quantum noise will also be limiting at low frequency. It will then be possible to use squeezed vacuum states having their amplitude fluctuations reduced at low frequency and their phase fluctuations reduced at high frequency. Thus, the total quantum noise can be reduced. Such states can be generated using an optical cavity called a filter cavity. The second part of the work presented in this thesis consisted in defining the optical parameters of the filter cavity that will be installed on Virgo for O4. To do this, it was first necessary to study the sources of degradation of the squeezed states of the vacuum. This then allowed defining the length of the filtering cavity and the set of parameters of the mirrors that compose it. Finally, the implementation of this filter cavity within the Virgo infrastructure was studied. This has shown that the use of compressed states will effectively reduce quantum noise over the entire sensitivity spectrum of Virgo.
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10−21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg’s uncertainty principle, ∆X1∆X2 ≥ 1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006. Thesis Supervisor: Nergis Mavalvala Title: Professor of Physics
Direct detection of gravitational waves will require
earth based detectors to measure strains of the order 10-21, at
frequencies of 100 Hz, a sensitivity that has been accomplished
with the initial generation of LIGO interferometric gravitational
wave detectors. A new generation of detectors currently under
construction is designed improve on the sensitivity of the initial
detectors by about a factor of 10. The quantum nature of light will
limit the sensitivity of these Advanced LIGO interferometers at
most frequencies; new approaches to reducing the quantum noise will
be needed to improve the sensitivity further. This quantum noise
originates from the vacuum fluctuations that enter the unused port
of the interferometer and interfere with the laser light. Vacuum
fluctuations have the minimum noise allowed by Heisenberg's
uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two
quadratures X1 and X2 are non-commuting observables responsible for
the two forms of quantum noise, shot noise and radiation pressure
noise. By replacing the vacuum fluctuations entering the
interferometer with squeezed states, which have lower noise in one
quadrature than the vacuum state, we have reduced the shot noise of
a LIGO interferometer. The sensitivity to gravitational waves
measured during this experiment represents the best sensitivity
achieved to date at frequencies above 200 Hz, and possibly the
first time that squeezing has been measured in an interferometer at
frequencies below 700 Hz. The possibility that injection of
squeezed states could introduce environmental noise couplings that
would degrade the crucial but fragile low frequency sensitivity of
a LIGO interferometer has been a major concern in planning to
implement squeezing as part of baseline interferometer operations.
These results demonstrate that squeezing is compatible with the low
frequency sensitivity of a full scale gravitational wave
interferometer. We also investigated the limits to the level of
squeezing observed, including optical losses and fluctuations of
the squeezing angle. The lessons learned should allow for
responsible planning to implement squeezing in Advanced LIGO,
either as an alternative to high power operation or an early
upgrade to improve the sensitivity. This thesis is available at
DSpace@MIT and has LIGO document number P1300006.
The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.
The detection of the binary neutron star inspiral GW170817 by the Advanced Laser Interferometer Gravitational Wave Observatory (LIGO) and Advanced Virgo, followed by counterpart observations across a broad electromagnetic spectrum, marks the dawn of multi-messenger astronomy. The discovery rate and potential of gravitational-wave astronomy is limited by the detector's sensitivity. A key challenge in improving the sensitivity of gravitational-wave detectors is to reduce quantum noise which arises due to the quantum nature of light. A well established technique to reduce the quantum noise in the detector is by replacing the coherent vacuum fluctuations entering the readout port with a squeezed vacuum state. This technique has been successfully demonstrated at the GEO-600 and LIGO Hanford detector, and is now in routine operation in current gravitational wave detectors. This thesis presents research from three experiments to develop quantum noise reduction techniques for next-generation gravitational wave detector using non-classical quantum states such as squeezed states. Current proposals for future generation gravitational wave detectors, such as LIGO Voyager, plan to utilise cryogenic silicon instead of fused silica as the test mass material. This is to improve the power handling of the detector and reduce thermal noise. The switch to silicon test masses requires a change of laser wavelength to the 2 micron region. In the first experiment, we built and operated the first squeezed vacuum source at a wavelength of 1984 nm. With a stable squeezing ellipse phase control employed, 3.9 dB of squeezing was measured, predominately limited by losses due to the low quantum efficiency of the photodiode. The squeezed vacuum system presented is compatible with future detectors and is a key pathfinder experiment to inform the design of cryogenic silicon interferometers. The quantum nature of light results in quantum radiation pressure noise that limits the low frequency sensitivity of gravitational wave detectors. In collaboration with Louisiana State University, the second experiment demonstrates the reduction of quantum radiation pressure noise by injecting bright squeezed light into a centimetre-scale optomechanical cavity at room temperature. The experiment involves the development and integration of a low-frequency bright squeezed source to reduce the quantum radiation pressure noise by 1.2 dB at 20 kHz. The result also represents the lowest frequency bright squeezed state measured from a crystal-based squeezer. Quadrature rotation of the injected squeezed state is required to achieve broadband quantum noise reduction in gravitational wave detectors due to the quantum back-action effect. This requires the squeezed state to interact with a low loss optical filter with a low frequency bandwidth prior to injection and represents a significant technical challenge. The final experiment presented in this thesis demonstrates an alternate method where frequency-dependent squeezing with Einstein-Podolsky-Rosen (EPR) entangled states is generated. When integrated into a gravitational wave detector, the alternate method allows the detector to simultaneously serve as the optical filter, eliminating the need for the additional apparatus.
Abstract In order to detect the small distance variations induced by gravitational waves, very sensitive devices must be used. Gravitational wave detectors are sophisticated interferometers sensitive even to vacuum fluctuations. These latter are responsible for quantum noise. Due to the frequency-dependent response of gravitational wave interferometers, quantum noise manifests itself as radiation pressure noise for frequencies below 100 Hz, while as shot noise for higher frequencies. The solution that has been adopted in order to reduce quantum noise is the injection, through the interferometer output port, of vacuum states, called squeezed, whose amplitude and phase uncertainties are correlated. A frequency-independent squeezing technique, as a method for the reduction of the quantum noise, has been already demonstrated in long-arm interferometers. Radiation pressure noise does not limit the sensitivity of the present interferometers, being this completely covered by other noises. But, in the near future, these noises will be reduced and also this quantum noise component will be relevant. The adopted solution to have a broad-band quantum noise reduction is a frequency-dependent squeezing technique. In this paper the results obtained in Advanced Virgo using the frequency-independent squeezing technique will be shown. Moreover the conceptual design for the implementation of the frequency-dependent squeezing will be presented.