Physica Scripta

Broadband quantum noise reduction via frequency dependent squeezing for Advanced Virgo Plus

E. Polini

Published May 18, 2021• 2 citations
Publisher

Abstract

Quantum noise is limiting the sensitivity of ground based gravitational wave detectors both at high frequency, in the form of shot noise, and low frequency, in the form of radiation pressure noise. In the last observing run, the injection of frequency independent squeezing improved Virgo and LIGO sensitivities at high frequency, slightly worsening the performance at low frequency. A broadband quantum noise reduction can be achieved using frequency dependent squeezing, i. e. rotating the vacuum squeezed ellipse below 100 Hz by reflecting the squeezed vacuum off a Fabry–Perot cavity, called filter cavity. The frequency-dependent squeezed quadrature rotation with rotation frequency around a few tens of Hz has been proven at National Astronomical Observatory of Japan (NAOJ) and at Massachusetts Institute of Technology (MIT). The experiment at NAOJ uses the former TAMA facility, a 300 meter long filter cavity, reproducing in scale the ones planned to be installed in Virgo and LIGO. Once the frequency dependent squeezing is produced, it has to be injected into the interferometer. This interface is not trivial, since it requires the installation of additional benches and a 285 meter long cavity (in Advanced Virgo Plus) and also to couple the rotating squeezed vacuum with the detector. An important issue which can worsen the performance of frequency dependent squeezing or directly the interferometer sensitivity is the stray light. To avoid the propagation of additional stray light, we traced the ghost beam on squeezing benches, inside linking tubes and inside the filter cavity and several diaphragms and baffles will be installed to limit this problem.

DOI
10.1088/1402-4896/abfef0

Related papers

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

Yang Zhao, N. Aritomi, E. Capocasa +20 more

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

arXiv:2003.10672•Physical Review Letters•Apr 28, 2020•123 citations

Frequency-Dependent Squeezing for Advanced LIGO

Lee P. McCuller, Chris Whittle, D. Ganapathy +13 more

The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."

arXiv:2003.13443•Physical Review Letters•Apr 28, 2020•222 citations

Frequency-Dependent Squeezed Vacuum Source for the Advanced Virgo Gravitational-Wave Detector

F. Acernese, M. Agathos, A. Ain +97 more

In this Letter, we present the design and performance of the frequency-dependent squeezed vacuum source that will be used for the broadband quantum noise reduction of the Advanced Virgo Plus gravitational-wave detector in the upcoming observation run. The frequency-dependent squeezed field is generated by a phase rotation of a frequency-independent squeezed state through a 285 m long, high-finesse, near-detuned optical resonator. With about 8.5 dB of generated squeezing, up to 5.6 dB of quantum noise suppression has been measured at high frequency while close to the filter cavity resonance frequency, the intracavity losses limit this value to about 2 dB. Frequency-dependent squeezing is produced with a rotation frequency stability of about 6 Hz rms, which is maintained over the long term. The achieved results fulfill the frequency dependent squeezed vacuum source requirements for Advanced Virgo Plus. With the current squeezing source, considering also the estimated squeezing degradation induced by the interferometer, we expect a reduction of the quantum shot noise and radiation pressure noise of up to 4.5 dB and 2 dB, respectively.

Physical Review Letters•Jul 25, 2023•65 citations

Quantum noise reduction using squeezed states in LIGO

S. E. Dwyer

Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10−21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg’s uncertainty principle, ∆X1∆X2 ≥ 1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006. Thesis Supervisor: Nergis Mavalvala Title: Professor of Physics

•Jan 1, 2013•32 citations

Quantum noise reduction using squeezed states inLIGO; Sensitivity improvement of a LIGO gravitational Waynedetector through squeezed state injection

S. E. Dwyer

Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.

•Jan 1, 2013•0 citations

Broadband Quantum Noise Reduction In A Small-Scale Suspended Interferometer With Quantum Entangled Squeezed Beams

W. Ali, B. Garaventa, S. Di Pace +3 more

General relativity predicts the existence of gravitational waves (GWs), ripples in spacetime that are now observable to highly sensitive interferometers. However, quantum noise poses a significant challenge for gravitational wave (GW) interferometers, influencing the entire bandwidth range (10-10,000 Hz) of the current GW detectors. At higher frequencies, shot noise (SN) predominates, while at lower frequencies, radiation-pressure noise (RPN) becomes the limiting factor, reducing both sensitivity and measurement precision. Squeezing techniques are implemented to address this issue by confining uncertainty within one quadrature of the light field. Starting from the observing run, O4 Virgo and LIGO have enhanced this method through frequency-dependent squeezing (FDS). By employing a 300-meter-long detuned filter cavity, the squeezing ellipse is rotated, allowing phase squeezing at high frequencies to reduce and amplitude squeezing at low frequencies to mitigate RPN, ultimately refining detection capabilities across the frequency spectrum. A promising alternative technique to reduce quantum noise across the entire sensitivity band uses Einstein-Podolsky-Rosen (EPR) quantum entanglement. This approach involves injecting two entangled squeezed beams at different frequencies into the dark port of the interferometer, enabling it to act as both a filter cavity and a gravitational wave detector. The Suspended Interferometer for Ponderomotive Squeezing (SIPS) adopts a large-scale GW detector layout, with a Michelson configuration and Fabry-Perot arm cavities. This system was initially thought to generate FDS in the GW frequency band using the ponderomotive technique. To enhance stability, a precise local control system was developed for the main optics of SIPS, which are suspended in a double pendulum configuration with monolithic fibers to reduce thermal noise. Advanced PXI-based data acquisition and position-sensitive detectors (PSDs) monitor angular and linear displacements, while real-time signal processing in LabVIEW enables corrective actuation, marking a significant step toward improved alignment and noise reduction in GW interferometry. The paper highlights the current status of SIPS, focusing on the local control strategy, underscoring its potential impact on the field.

International Journal of Environmental Sciences•Aug 4, 2025•0 citations
Quantum noise is limiting the sensitivity of ground based gravitational wave detectors both at high frequency, in the form of shot noise, and low frequency, in the form of radiation pressure noise. In the last observing run, the injection of frequency independent squeezing improved Virgo and LIGO sensitivities at high frequency, slightly worsening the performance at low frequency. A broadband quantum noise reduction can be achieved using frequency dependent squeezing, i. e. rotating the vacuum squeezed ellipse below 100 Hz by reflecting the squeezed vacuum off a Fabry–Perot cavity, called filter cavity. The frequency-dependent squeezed quadrature rotation with rotation frequency around a few tens of Hz has been proven at National Astronomical Observatory of Japan (NAOJ) and at Massachusetts Institute of Technology (MIT). The experiment at NAOJ uses the former TAMA facility, a 300 meter long filter cavity, reproducing in scale the ones planned to be installed in Virgo and LIGO. Once the frequency dependent squeezing is produced, it has to be injected into the interferometer. This interface is not trivial, since it requires the installation of additional benches and a 285 meter long cavity (in Advanced Virgo Plus) and also to couple the rotating squeezed vacuum with the detector. An important issue which can worsen the performance of frequency dependent squeezing or directly the interferometer sensitivity is the stray light. To avoid the propagation of additional stray light, we traced the ghost beam on squeezing benches, inside linking tubes and inside the filter cavity and several diaphragms and baffles will be installed to limit this problem.
The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.
The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
In this Letter, we present the design and performance of the frequency-dependent squeezed vacuum source that will be used for the broadband quantum noise reduction of the Advanced Virgo Plus gravitational-wave detector in the upcoming observation run. The frequency-dependent squeezed field is generated by a phase rotation of a frequency-independent squeezed state through a 285 m long, high-finesse, near-detuned optical resonator. With about 8.5 dB of generated squeezing, up to 5.6 dB of quantum noise suppression has been measured at high frequency while close to the filter cavity resonance frequency, the intracavity losses limit this value to about 2 dB. Frequency-dependent squeezing is produced with a rotation frequency stability of about 6 Hz rms, which is maintained over the long term. The achieved results fulfill the frequency dependent squeezed vacuum source requirements for Advanced Virgo Plus. With the current squeezing source, considering also the estimated squeezing degradation induced by the interferometer, we expect a reduction of the quantum shot noise and radiation pressure noise of up to 4.5 dB and 2 dB, respectively.
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10−21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg’s uncertainty principle, ∆X1∆X2 ≥ 1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006. Thesis Supervisor: Nergis Mavalvala Title: Professor of Physics
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.
General relativity predicts the existence of gravitational waves (GWs), ripples in spacetime that are now observable to highly sensitive interferometers. However, quantum noise poses a significant challenge for gravitational wave (GW) interferometers, influencing the entire bandwidth range (10-10,000 Hz) of the current GW detectors. At higher frequencies, shot noise (SN) predominates, while at lower frequencies, radiation-pressure noise (RPN) becomes the limiting factor, reducing both sensitivity and measurement precision. Squeezing techniques are implemented to address this issue by confining uncertainty within one quadrature of the light field. Starting from the observing run, O4 Virgo and LIGO have enhanced this method through frequency-dependent squeezing (FDS). By employing a 300-meter-long detuned filter cavity, the squeezing ellipse is rotated, allowing phase squeezing at high frequencies to reduce and amplitude squeezing at low frequencies to mitigate RPN, ultimately refining detection capabilities across the frequency spectrum. A promising alternative technique to reduce quantum noise across the entire sensitivity band uses Einstein-Podolsky-Rosen (EPR) quantum entanglement. This approach involves injecting two entangled squeezed beams at different frequencies into the dark port of the interferometer, enabling it to act as both a filter cavity and a gravitational wave detector. The Suspended Interferometer for Ponderomotive Squeezing (SIPS) adopts a large-scale GW detector layout, with a Michelson configuration and Fabry-Perot arm cavities. This system was initially thought to generate FDS in the GW frequency band using the ponderomotive technique. To enhance stability, a precise local control system was developed for the main optics of SIPS, which are suspended in a double pendulum configuration with monolithic fibers to reduce thermal noise. Advanced PXI-based data acquisition and position-sensitive detectors (PSDs) monitor angular and linear displacements, while real-time signal processing in LabVIEW enables corrective actuation, marking a significant step toward improved alignment and noise reduction in GW interferometry. The paper highlights the current status of SIPS, focusing on the local control strategy, underscoring its potential impact on the field.