Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Single-beam NMOR atomic magnetometer based on a fiberized EOM

Mengnan Tian, Wei Quan, Liwei Jiang, Jiali Liu, Yanchao Chai, Zhenglong Lu, Xin Hui Zhao

Published May 16, 2023• 29 citations
Publisher

Abstract

The high-precision and portable nonlinear magneto-optical rotation (NMOR) atomic magnetometer has significant potential in the direction of magnetic field measurement under a geomagnetic environment. Here, we propose a single-beam NMOR atomic magnetometer with amplitude modulation based on a fiberized electro-optic modulator (EOM) for the first time, to the best of our knowledge, which provides a feasible scheme for the integrated design. A theoretical model of the system response signal as a function of the modulation amplitude is established by a Jones matrix. Based on the theoretical model, the influence mechanism of the modulation amplitude on the system response signal is further analyzed and the optimal modulation parameters can be determined. Finally, a sensitivity of 42.67 fT/Hz1/2 at 50-µT magnetic field is achieved. The proposed scheme is also applicable to other magnetometers under a geomagnetic environment.

DOI
10.1364/ol.494469

Related papers

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•6 citations

Miniaturized atomic magnetometer employing pump-beam modulation

Ziqian Yue, Junjian Tang, Yueyang Zhai

Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).

Advanced Sensor Systems and Applications•Oct 11, 2024•0 citations

Dual-beam room-temperature atomic magnetometer with high sensitivity and large dynamic range

Bei Liu, Jin Peng, Haining Wang +4 more

Abstract We demonstrate a dual-beam high-sensitivity room-temperature atomic magnetometer (AM) with a large dynamic range based on a nonlinear magneto-optical rotation (NMOR) enhancing scheme. Using an inelastic wave-mixing laser, we find significant NMOR signal enhancement compared with a single-beam scheme under the same far-detuned operation conditions. This dual-beam scheme is shown to operate well in the regime of lower laser intensity and off-resonance detuning. The best sensitivity achieved is 20 fT/Hz1/2 with a bandwidth of 2 kHz, substantially greater than common spin-exchange relaxation-free AMs. This provides a way to develop low-power, inexpensive miniaturized AMs for wide application.

Applied Physics Express•Dec 8, 2022•10 citations

An electro-optic modulator detection method in all optical atomic magnetometer

Yanhui Hu, Xuejing Liu, Yang Li +1 more

An electro-optic modulator (EOM) detection method is demonstrated to detect the optical atomic precession in the Spin-Exchange Relaxation Free (SERF) atomic magnetometer, which achieved a sensitivity of ~30 fT/Hz1/2 at the calibration frequency of 30Hz. The SERF atomic magnetometer based on EOM presents several advantages, such as simple structure, no magnetic shielding, moderate thermal effect and high measurement accuracy. It is demonstrated to be feasible for the compactness and simplicity of atomic magnetic field measurement devices in the future.

Third Asia Pacific Optical Sensors Conference•Jan 1, 2016•3 citations

Improving sensitivity of an amplitude-modulated magneto-optical atomic magnetometer using squeezed light

Jiahui Li, Irina V. Novikova

We experimentally demonstrate that a squeezed probe optical field can improve the sensitivity of magnetic field measurements based on nonlinear magneto-optical rotation (NMOR) with an amplitude-modulated pump when compared to a coherent probe field under identical conditions. To realize an all-atomic magnetometer prototype, we utilize a nonlinear atomic interaction, known as polarization self-rotation, to produce a squeezed probe field. An independent pump field, amplitude-modulated at the Larmor frequency of the bias magnetic field, allows us to extend the range of most sensitive NMOR measurements to sub-Gauss magnetic fields. While the overall sensitivity of the magnetometer is rather low ( > 250 p T / H z ), we clearly observe a 15 % sensitivity improvement when the squeezed probe is used. Our observations confirm the recently reported quantum enhancement in a modulated atomic magnetometer [ Phys. Rev. Lett. 127 , 193601 ( 2021 ) PRLTAO 0031-9007 10.1103/PhysRevLett.127.193601 ].

arXiv:2207.12962•Journal of the Optical Society of America B•Oct 5, 2022•15 citations

Refined analysis and representation of atomic polarization in NMOR atomic magnetometers

Yanchao Chai, Liwei Jiang, Jiali Liu +5 more

The nonlinear magneto-optical rotation (NMOR) atomic magnetometer is a highly sensitive total-field device with significant applications in fundamental physics, geophysics, and biomedical monitoring. The atomic polarization, which is optically induced through resonant light pumping, plays a pivotal role in determining the sensitivity and stability of the magnetometer. In this paper, refined analysis and representation of atomic polarization in NMOR atomic magnetometers are presented through the establishment of a three-dimensional polarization distribution model based on the rate equation. The polarization characteristics of the single-beam pump and repump modes are compared, and the scale factors of both modes are experimentally measured. Both simulation and experimental results demonstrate that the proposed model accurately captures the spatial distribution of optically induced polarization, which is essential for improving the performance and extending the application potential of NMOR magnetometers in high-sensitivity optical sensing systems.

Optics Express•Jul 15, 2025•1 citation
The high-precision and portable nonlinear magneto-optical rotation (NMOR) atomic magnetometer has significant potential in the direction of magnetic field measurement under a geomagnetic environment. Here, we propose a single-beam NMOR atomic magnetometer with amplitude modulation based on a fiberized electro-optic modulator (EOM) for the first time, to the best of our knowledge, which provides a feasible scheme for the integrated design. A theoretical model of the system response signal as a function of the modulation amplitude is established by a Jones matrix. Based on the theoretical model, the influence mechanism of the modulation amplitude on the system response signal is further analyzed and the optimal modulation parameters can be determined. Finally, a sensitivity of 42.67 fT/Hz1/2 at 50-µT magnetic field is achieved. The proposed scheme is also applicable to other magnetometers under a geomagnetic environment.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).
Abstract We demonstrate a dual-beam high-sensitivity room-temperature atomic magnetometer (AM) with a large dynamic range based on a nonlinear magneto-optical rotation (NMOR) enhancing scheme. Using an inelastic wave-mixing laser, we find significant NMOR signal enhancement compared with a single-beam scheme under the same far-detuned operation conditions. This dual-beam scheme is shown to operate well in the regime of lower laser intensity and off-resonance detuning. The best sensitivity achieved is 20 fT/Hz1/2 with a bandwidth of 2 kHz, substantially greater than common spin-exchange relaxation-free AMs. This provides a way to develop low-power, inexpensive miniaturized AMs for wide application.
An electro-optic modulator (EOM) detection method is demonstrated to detect the optical atomic precession in the Spin-Exchange Relaxation Free (SERF) atomic magnetometer, which achieved a sensitivity of ~30 fT/Hz1/2 at the calibration frequency of 30Hz. The SERF atomic magnetometer based on EOM presents several advantages, such as simple structure, no magnetic shielding, moderate thermal effect and high measurement accuracy. It is demonstrated to be feasible for the compactness and simplicity of atomic magnetic field measurement devices in the future.
We experimentally demonstrate that a squeezed probe optical field can improve the sensitivity of magnetic field measurements based on nonlinear magneto-optical rotation (NMOR) with an amplitude-modulated pump when compared to a coherent probe field under identical conditions. To realize an all-atomic magnetometer prototype, we utilize a nonlinear atomic interaction, known as polarization self-rotation, to produce a squeezed probe field. An independent pump field, amplitude-modulated at the Larmor frequency of the bias magnetic field, allows us to extend the range of most sensitive NMOR measurements to sub-Gauss magnetic fields. While the overall sensitivity of the magnetometer is rather low ( > 250 p T / H z ), we clearly observe a 15 % sensitivity improvement when the squeezed probe is used. Our observations confirm the recently reported quantum enhancement in a modulated atomic magnetometer [ Phys. Rev. Lett. 127 , 193601 ( 2021 ) PRLTAO 0031-9007 10.1103/PhysRevLett.127.193601 ].
The nonlinear magneto-optical rotation (NMOR) atomic magnetometer is a highly sensitive total-field device with significant applications in fundamental physics, geophysics, and biomedical monitoring. The atomic polarization, which is optically induced through resonant light pumping, plays a pivotal role in determining the sensitivity and stability of the magnetometer. In this paper, refined analysis and representation of atomic polarization in NMOR atomic magnetometers are presented through the establishment of a three-dimensional polarization distribution model based on the rate equation. The polarization characteristics of the single-beam pump and repump modes are compared, and the scale factors of both modes are experimentally measured. Both simulation and experimental results demonstrate that the proposed model accurately captures the spatial distribution of optically induced polarization, which is essential for improving the performance and extending the application potential of NMOR magnetometers in high-sensitivity optical sensing systems.