Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Cold-Atom-Based Commercial Microwave Clock at the 10−15 Level

Bruno Pelle, Ramon Szmuk, Bruno Desruelle, David Holleville, Arnaud Landragin

Published May 1, 2018• 5 citations
Publisher

Abstract

Laser cooled atomic clocks allow to both extend spectroscopy duration and better control the systematics. We present a commercial microwave clock that achieve an extreme stability of 3.2×10-13at 1 s and 1×10-15in less than 2 days, with a turnkey product dedicated for continuous long-term operation.
DOI
10.1109/fcs.2018.8597468

Related papers

Cold-atom-based commercial microwave clock at the 10−15 level

Bruno Pelle, Bruno Desruelle, Ramon Szmuk +1 more

Laser cooled atomic clocks allow to both extend spectroscopy duration and better control the systematics. We present a commercial microwave clock that achieve an extreme stability and accuracy in the 10-15range within a day, with a turnkey product dedicated for continuous long-term operation.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•4 citations

Towards an Accuracy Budget of Cold-Atom-Based Commercial Microwave Clocks

Luc Archambault, Floriane Sparma, L. Lorini +4 more

We present results of commercial microwave clocks developed by Exail Quantum Systems (formerly Muquans). The MuClocks are cold-atom-based turnkey products dedicated to continuous long-term operation. A frequency stability of 1×10-15 over more than a month has been demonstrated on several set-ups, competing with the frequency drift (~1×10-16/day) of the best masers. Recent stability evaluations show for the best clock a long-term frequency stability of 7×10-16 over two weeks and for the longest run ~2×10-15 over two months. IIn this contribution, we will present a preliminary accuracy budget, the targeted product accuracy being in the 5×10-15 range. Control and evaluation of the known frequency biases is on-going. Several frequency shifts have already been quantified: the Quadratic Zeeman shift, the cavity pulling including its asymmetry from nearby cavity resonances, microwave phase transients and the Ramsey pulling.

•Jun 25, 2024•0 citations

Progress Towards a Compact Cold-Atom Microwave Clock

Martin Knapp, S Walby, Mohsin Haji +2 more

Here we present progress towards a compact cold-atom microwave clock. The system we have developed is currently a demonstrator for a clock architecture whereby a cloud of laser-cooled caesium atoms are dropped and interrogated during free fall. We describe the experimental sequence as well as show preliminary results related to signal-to-noise ratio limits and Rabi microwave spectroscopy.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 15, 2023•0 citations

Development of a portable laser-cooled ytterbium ion microwave atomic clock

Sean Mulholland

Portable microwave clocks that incorporate laser cooling promise to bring significantly improved performance compared to commercially available microwave clocks that are based on thermal atoms. This thesis reports on the development of a portable, laser-cooled ytterbium-171 trapped-ion microwave frequency standard from design to testing.

•Jan 1, 2019•1 citation

Development of compact laser cooled atomic frequency standards

T. Zanon-Willette, S. Trémine, Stéphane Guérandel +4 more

Two projects of compact cold atom clocks are currently developed: a clock with atoms directly cooled in the microwave cavity and a clock based on coherent population trapping. For each device, different interrogation and detection schemes are evaluated and reported

Conference on Precision Electromagnetic Measurements•Jun 1, 2004•1 citation

In-orbit operation of an atomic clock based on laser-cooled 87Rb atoms

Liang Liu, Desheng Lü, Weibiao Chen +23 more

Abstract Atomic clocks based on laser-cooled atoms are widely used as primary frequency standards. Deploying such cold atom clocks (CACs) in space is foreseen to have many applications. Here we present tests of a CAC operating in space. In orbital microgravity, the atoms are cooled, trapped, launched, and finally detected after being interrogated by a microwave field using the Ramsey method. Perturbing influences from the orbital environment on the atoms such as varying magnetic fields and the passage of the spacecraft through Earth’s radiation belt are also controlled and mitigated. With appropriate parameters settings, closed-loop locking of the CAC is realized in orbit and an estimated short-term frequency stability close to 3.0 × 10 −13 τ −1/2 has been attained. The demonstration of the long-term operation of cold atom clock in orbit opens possibility on the applications of space-based cold atom sensors.

Nature Communications•Jul 11, 2018•189 citations
We present results of commercial microwave clocks developed by Exail Quantum Systems (formerly Muquans). The MuClocks are cold-atom-based turnkey products dedicated to continuous long-term operation. A frequency stability of 1×10-15 over more than a month has been demonstrated on several set-ups, competing with the frequency drift (~1×10-16/day) of the best masers. Recent stability evaluations show for the best clock a long-term frequency stability of 7×10-16 over two weeks and for the longest run ~2×10-15 over two months. IIn this contribution, we will present a preliminary accuracy budget, the targeted product accuracy being in the 5×10-15 range. Control and evaluation of the known frequency biases is on-going. Several frequency shifts have already been quantified: the Quadratic Zeeman shift, the cavity pulling including its asymmetry from nearby cavity resonances, microwave phase transients and the Ramsey pulling.
Abstract Atomic clocks based on laser-cooled atoms are widely used as primary frequency standards. Deploying such cold atom clocks (CACs) in space is foreseen to have many applications. Here we present tests of a CAC operating in space. In orbital microgravity, the atoms are cooled, trapped, launched, and finally detected after being interrogated by a microwave field using the Ramsey method. Perturbing influences from the orbital environment on the atoms such as varying magnetic fields and the passage of the spacecraft through Earth’s radiation belt are also controlled and mitigated. With appropriate parameters settings, closed-loop locking of the CAC is realized in orbit and an estimated short-term frequency stability close to 3.0 × 10 −13 τ −1/2 has been attained. The demonstration of the long-term operation of cold atom clock in orbit opens possibility on the applications of space-based cold atom sensors.