Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Recent progress of neutral mercury lattice clock in SIOM

X H Fu, S Fang, R C Zhao, J F Sun, Z. S. Xu, Y Z Wang

Published Jul 1, 2017• 0 citations
Publisher

Abstract

The optical lattice clock develops fast in recent years, and its stability and accuracy has already surpassed the microwave fountain clock and the optical clock based on ion trap. The mercury (Hg) lattice clock has the possibility to make a breakthrough in the limitation of blackbody radiation shift for strontium (Sr) and ytterbium (Yb) lattice clock, and reach the uncertainty in E-18 level at room temperature. For the purposes of laser cooling of mercury atoms and interrogating of the clock transition from1S0state to3P0state, a high-power cooling laser at 253.7 nm and an ultra-stable Hz-level linewidth laser at 265.6 nm are required, respectively. Here, we report our development of these laser sources for a neutral Hg lattice clock.

DOI
10.1109/fcs.2017.8088917

Related papers

Recent progress of neutral mercury lattice clock in SIOM

R C Zhao, Xiaoyan Fu, K K Liu +4 more

Neutral mercury atom is one of good candidates of optical lattice clock. Due to its large atomic number, mercury atom is insensitive to black body radiation, which is the severe limitation for the development of optical clocks. However, the challenge of neutral mercury lattice clock is the requirement of high power deep-UV lasers, especially for both the cooling laser and the lattice laser. Here, we report the recent progress of neutral mercury lattice clock in SIOM, including the development for laser cooling of mercury atom and the cooling laser system with fiber laser amplifier. We have realized the magneto-optical trap of mercury atoms and measured the parameters of cold mercury atoms. A home-made external cavity diode laser works as a seed laser for a room temperature 1014.8 nm fiber laser amplifier. A new efficient frequency-doubling cavity from 1015 nm to 507 nm has been developed.

Journal of Physics Conference Series•Jun 1, 2016•0 citations

Recent Progress of Mercury Lattice Clock in SIOM

Qixin Liu, Ye Zhang, Zexin Yu +2 more

To realize a neutral mercury lattice clock, an experimental setup is in developing in SIOM. With two stable cooling lasers and a new vacuum system, an enhanced cold mercury atom source is implemented based on a two-dimensional magneto-optical trap (2D-MOT). By applying a hybrid frequency stabilization method and optimization of the 2D-MOT, about 1.3×106cold mercury atoms are obtained with a loading rate of 1.0×106atoms/s. And a high power injection-locked Ti:sapphire laser at 725 nm is developed for optical lattice at magic-wavelength.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 24, 2022•0 citations

Recent progress of laser cooling for neutral mercury atom

Kangkang Liu, Ru-Chen Zhao, Xiaohu Fu +4 more

Mercury is the heaviest stable atom that could be laser cooled, and have a large nuclear charge number. So it has a distinct advantage in quantum precision measurement such as fine-structure constant α and permanent electric dipole moment. Due to its insensitivity of black body radiation, atomic mercury is a good candidate of optical clock. Here we report our recent development of laser cooling of neutral mercury atom. By cooling the mercury source to about -70°C, an ultra-high vacuum system was realized to produce ultracold mercury atoms. The commercial frequency quadrupled semiconductor laser is locked on the cooling transition (1S0-3P1 transition, wavelength of 253.7 nm) by sub-Doppler frequency modulation spectroscopy. By the modification with feed-forward method, the UV laser becomes faster tunable and more stable. A folded beam configuration was used to realize the magneto-optical trap (MOT) because of the shortage of cooling laser power, and the ultracold mercury atoms were observed by fluorescence detection. All of six rich abundant isotopes have been observed, and the atom number is about 1.5×106 with density of 3.5×109 /cm3 for 202Hg. With optical shutter and the programmable system to control the time sequence, the temperature of ultracold atoms can be measured by time of flight method. To enhance the laser power, a 1014.8 nm fiber laser amplifier was developed, which can work at room temperature. After two stages of frequency doubling, about 75 mW of 253.7 nm UV laser were generated, and the saturated absorption spectroscopy of mercury atom was also observed. More power of UV laser could help to trap more atoms in the future. These works laid a good foundation to realize the mercury lattice clock.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 18, 2014•0 citations

Towards an optical lattice clock based on neutral mercury

C. Mandache, Petersen, Michael, Daniel Varela Magalhães +3 more

We are investigating the possibilities of using neutral mercury as a new species to realize a highly accurate atomic clock using the non-perturbing dipole lattice trapping scheme. Typically, accuracy below 10-17 is targeted, which would make neutral mercury an interesting candidate for a redefinition of the SI second. This paper presents our on-going work towards the realization of an optical lattice clock using neutral mercury. We will describe a 254 nm laser source delivering several hundreds of milliWatts at this wavelength with a suitably low frequency noise for laser cooling and magneto-optic trapping. We will describe our vacuum system for magneto-optic trap and report on the status of our work regarding magneto-optic trapping of mercury. We will also describe our clock laser at 266 nm.

•Jan 1, 2008•0 citations

Magneto-optical trap for neutral mercury atoms

Hongli Liu, Shiqi Yin, Kangkang Liu +4 more

Due to its low sensitivity to blackbody radiation, neutral mercury is a good candidate for the most accurate optical lattice clock. Here we report the observation of cold mercury atoms in a magneto-optical trap (MOT). Because of the high vapor pressure at room temperature, the mercury source and the cold pump were cooled down to −40 °C and −70 °C, respectively, to keep the science chamber in an ultra-high vacuum of 6 × 10 −9 Pa. Limited by the power of the UV cooling laser, the one beam folded MOT configuration was adopted, and 1.5 × 10 5 Hg-202 atoms were observed by fluorescence detection.

Chinese Physics B•Apr 1, 2013•19 citations

Frequency comparisons of Sr, Yb, and Hg based optical lattice clocks and their applications

Hidetoshi Katori, Ichiro Ushijima, Manoj Das +8 more

We report recent progress of optical lattice clocks with strontium, ytterbium and mercury atoms with an emphasis on their synchronous frequency comparison inside a laboratory and inter-laboratories connected by a phase-stabilized fiber link.

•Jan 1, 2015•1 citation
The optical lattice clock develops fast in recent years, and its stability and accuracy has already surpassed the microwave fountain clock and the optical clock based on ion trap. The mercury (Hg) lattice clock has the possibility to make a breakthrough in the limitation of blackbody radiation shift for strontium (Sr) and ytterbium (Yb) lattice clock, and reach the uncertainty in E-18 level at room temperature. For the purposes of laser cooling of mercury atoms and interrogating of the clock transition from1S0state to3P0state, a high-power cooling laser at 253.7 nm and an ultra-stable Hz-level linewidth laser at 265.6 nm are required, respectively. Here, we report our development of these laser sources for a neutral Hg lattice clock.
Neutral mercury atom is one of good candidates of optical lattice clock. Due to its large atomic number, mercury atom is insensitive to black body radiation, which is the severe limitation for the development of optical clocks. However, the challenge of neutral mercury lattice clock is the requirement of high power deep-UV lasers, especially for both the cooling laser and the lattice laser. Here, we report the recent progress of neutral mercury lattice clock in SIOM, including the development for laser cooling of mercury atom and the cooling laser system with fiber laser amplifier. We have realized the magneto-optical trap of mercury atoms and measured the parameters of cold mercury atoms. A home-made external cavity diode laser works as a seed laser for a room temperature 1014.8 nm fiber laser amplifier. A new efficient frequency-doubling cavity from 1015 nm to 507 nm has been developed.
To realize a neutral mercury lattice clock, an experimental setup is in developing in SIOM. With two stable cooling lasers and a new vacuum system, an enhanced cold mercury atom source is implemented based on a two-dimensional magneto-optical trap (2D-MOT). By applying a hybrid frequency stabilization method and optimization of the 2D-MOT, about 1.3×106cold mercury atoms are obtained with a loading rate of 1.0×106atoms/s. And a high power injection-locked Ti:sapphire laser at 725 nm is developed for optical lattice at magic-wavelength.
Mercury is the heaviest stable atom that could be laser cooled, and have a large nuclear charge number. So it has a distinct advantage in quantum precision measurement such as fine-structure constant α and permanent electric dipole moment. Due to its insensitivity of black body radiation, atomic mercury is a good candidate of optical clock. Here we report our recent development of laser cooling of neutral mercury atom. By cooling the mercury source to about -70°C, an ultra-high vacuum system was realized to produce ultracold mercury atoms. The commercial frequency quadrupled semiconductor laser is locked on the cooling transition (1S0-3P1 transition, wavelength of 253.7 nm) by sub-Doppler frequency modulation spectroscopy. By the modification with feed-forward method, the UV laser becomes faster tunable and more stable. A folded beam configuration was used to realize the magneto-optical trap (MOT) because of the shortage of cooling laser power, and the ultracold mercury atoms were observed by fluorescence detection. All of six rich abundant isotopes have been observed, and the atom number is about 1.5×106 with density of 3.5×109 /cm3 for 202Hg. With optical shutter and the programmable system to control the time sequence, the temperature of ultracold atoms can be measured by time of flight method. To enhance the laser power, a 1014.8 nm fiber laser amplifier was developed, which can work at room temperature. After two stages of frequency doubling, about 75 mW of 253.7 nm UV laser were generated, and the saturated absorption spectroscopy of mercury atom was also observed. More power of UV laser could help to trap more atoms in the future. These works laid a good foundation to realize the mercury lattice clock.
We are investigating the possibilities of using neutral mercury as a new species to realize a highly accurate atomic clock using the non-perturbing dipole lattice trapping scheme. Typically, accuracy below 10-17 is targeted, which would make neutral mercury an interesting candidate for a redefinition of the SI second. This paper presents our on-going work towards the realization of an optical lattice clock using neutral mercury. We will describe a 254 nm laser source delivering several hundreds of milliWatts at this wavelength with a suitably low frequency noise for laser cooling and magneto-optic trapping. We will describe our vacuum system for magneto-optic trap and report on the status of our work regarding magneto-optic trapping of mercury. We will also describe our clock laser at 266 nm.
Due to its low sensitivity to blackbody radiation, neutral mercury is a good candidate for the most accurate optical lattice clock. Here we report the observation of cold mercury atoms in a magneto-optical trap (MOT). Because of the high vapor pressure at room temperature, the mercury source and the cold pump were cooled down to −40 °C and −70 °C, respectively, to keep the science chamber in an ultra-high vacuum of 6 × 10 −9 Pa. Limited by the power of the UV cooling laser, the one beam folded MOT configuration was adopted, and 1.5 × 10 5 Hg-202 atoms were observed by fluorescence detection.