Journal of Physics Conference Series

Modified quantum frequency standard on Hg-199 ions

Nikita A. Lukashev, Vadim Vladimirovich Davydov, V. Yu. Rud’

Published Dec 1, 2021• 0 citations
Publisher

Abstract

Abstract The world around us depends on devices capable of producing or maintaining a signal with an extreme precision. Quantum frequency standards are the answer to this problem. This article presents a modified version of newly developed quantum frequency standard based on trapping Hg-199 ions by magnetic field. The new prototype was developed a while ago and now it was modified due to algorithm improvements and renewed digital hardware, analog and digital circuitry being reordered. Results for Allan deviation show 3 % improvement for long-term frequency stability and more than 5 % for short-term stability

DOI
10.1088/1742-6596/2086/1/012060

Related papers

New processing algorithm in quantum frequency standard on Hg-199 ions

Nikita A. Lukashev, Vadim Vladimirovich Davydov, Alexey P. Glinushkin

Abstract In the paper the new processing algorithm for low mass-dimensional microwave frequency standards is developed. The newly constructed design for the driver system is presented. The comparisons of experimental Allan deviation data for the previously designed prototype are performed.

Journal of Physics Conference Series•Dec 1, 2020•3 citations

Microwave frequency standard on Hg-199 ions for space stations and vehicles

Nikita A. Lukashev, Vadim Vladimirovich Davydov, V. Yu. Rud’

Abstract In the paper the design of a magnetic trap for low mass-dimensional microwave frequency standards is presented. The dependencies between the number of registered photons by PMT and magnetic field values are established. The new algorithm for optical processing is developed. For different designs of microwave standard on 199Hg+ ions the results comparison of experimental Allan deviation researches is performed.

Journal of Physics Conference Series•Nov 1, 2019•11 citations

Microwave low mass-dimensional frequency standard on Hg- 199 ions

Nikita A. Lukashev, Vadim Vladimirovich Davydov, Alexey P. Glinushkin +2 more

Abstract In the paper the design of a magnetic trap for low mass-dimensional microwave frequency standards is presented. The dependencies between the number of registered photons by PMT and magnetic field values are established. The new algorithm for optical processing is developed. The results comparison of experimental Allan deviation researches for different designs of microwave standard on 199Hg+ ions are performed.

Journal of Physics Conference Series•Dec 1, 2019•16 citations

Compact microwave frequency standard on Hg-199 ions for navigation systems

Nikita A. Lukashev, Angelina V. Moroz, Vadim Vladimirovich Davydov

Abstract The design of a magnetic trap for low mass-dimensional microwave frequency standards is presented. The dependencies of the number of photons registered by PMT on magnetic field values are established. The new algorithm for optical processing has been developed. The comparison of experimental Allan deviation for different designs of microwave frequency standards on 199Hg+ ions has been performed.

Journal of Physics Conference Series•Jun 1, 2019•28 citations

Characteristics Analysis of Different Models of Quantum Frequency Standard on Mercury-199 Ions

Ding Wang, Vadim Vladimirovich Davydov

New trends in the development of navigation systems and the tasks to be solved using global navigation satellite systems, as well as the creation of the basis for deep space exploration have forced changes in the requirements for quantum frequency standards, especially in terms of frequency stability without communication sessions with the Earth. The corresponding new requirement quantum frequency standard is the quantum frequency standard on mercury-199 ions. This is now the most promising frequency standard for space systems, especially for deep space exploration. To determine the directions of modernization of the design of the quantum frequency standard on mercury-199 ions (by the new requirements), we collected and summarized information about the current research of the quantum frequency standard on mercury-199 ions in different countries of the world (USA, Russia, European Union, and China). For the first time, we performed an extended analysis comparing the characteristics of different models of quantum frequency standard on mercury-199 ions, which differ mainly in the ion traps and light sources for the excitation of mercury-202. The analysis of the technical characteristic of the quantum frequency standard on the mercury-199 ions, as well as our data on calculations of ion trap design with different electrode configurations, showed that long-term stability (105s) of the USA and Chinese models is an order of magnitude higher than that of the Russian and European Union models. The data are comparable in terms of short-term stability at the initial stage of operation. This confirmed our calculations from the parameters of the traps on the effect of electrode fabrication technologies on frequency stability. At present, this problem has not received adequate consideration in the world.

International Conference on Electrical Engineering and Photonics (EExPolytech)•Oct 19, 2023•0 citations

Improving characteristics of microwave frequency standard on Hg-199 ions for telecommunication systems

Nikita A. Lukashev, Roman V. Davydov, Alexey P. Glinushkin +1 more

Abstract The article presents the development of a new low mass-dimensional microwave frequency standard on Hg-199 ions. The optimal ion trap parameters are calculated. The new control algorithm is developed. The compact driver for trap field is constructed. The experimental data received show the decrease in size and mass while saving precision characteristics.

Journal of Physics Conference Series•Oct 1, 2019•14 citations
Abstract The world around us depends on devices capable of producing or maintaining a signal with an extreme precision. Quantum frequency standards are the answer to this problem. This article presents a modified version of newly developed quantum frequency standard based on trapping Hg-199 ions by magnetic field. The new prototype was developed a while ago and now it was modified due to algorithm improvements and renewed digital hardware, analog and digital circuitry being reordered. Results for Allan deviation show 3 % improvement for long-term frequency stability and more than 5 % for short-term stability
New trends in the development of navigation systems and the tasks to be solved using global navigation satellite systems, as well as the creation of the basis for deep space exploration have forced changes in the requirements for quantum frequency standards, especially in terms of frequency stability without communication sessions with the Earth. The corresponding new requirement quantum frequency standard is the quantum frequency standard on mercury-199 ions. This is now the most promising frequency standard for space systems, especially for deep space exploration. To determine the directions of modernization of the design of the quantum frequency standard on mercury-199 ions (by the new requirements), we collected and summarized information about the current research of the quantum frequency standard on mercury-199 ions in different countries of the world (USA, Russia, European Union, and China). For the first time, we performed an extended analysis comparing the characteristics of different models of quantum frequency standard on mercury-199 ions, which differ mainly in the ion traps and light sources for the excitation of mercury-202. The analysis of the technical characteristic of the quantum frequency standard on the mercury-199 ions, as well as our data on calculations of ion trap design with different electrode configurations, showed that long-term stability (105s) of the USA and Chinese models is an order of magnitude higher than that of the Russian and European Union models. The data are comparable in terms of short-term stability at the initial stage of operation. This confirmed our calculations from the parameters of the traps on the effect of electrode fabrication technologies on frequency stability. At present, this problem has not received adequate consideration in the world.