Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer eBooks

Superconducting Quantum Detector for Astronomy and X -Ray Spectroscopy

Alexei D. Semenov, Heinz‐Wilhelm Hübers, Gregory N Gol'tsman, Смирнов Константин Владимирович

Published Jan 1, 2002• 0 citations
Publisher
DOI
10.1007/978-1-4615-0737-6_22

Related papers

Superconducting Quantum Detector for Astronomy and X-Ray

Alexei D. Semenov, Heinz‐Wilhelm Hübers, Gregory N Gol'tsman +1 more

•Jan 1, 2001•0 citations

Background Limited Superconducting Quantum Detector for Astronomy

Alexei D. Semenov, Heinz‐Wilhelm Hübers, Andreas Engel +1 more

•Jan 1, 2002•0 citations

Superconducting X-ray detectors

Can Hui Yang, Mengting Si, Lixing You

Science China Information Sciences•Jul 15, 2020•12 citations

Superconducting Tunnel Junctions as Single Photon X-Ray Detectors.

Michael C. Gaidis

•Jan 1, 1994•7 citations

Ultimate performance of a superconducting quantum detector

Alexei D. Semenov, Andreas Engel, K. Ilin +3 more

We analyze the ultimate performance of a superconducting quantum detector in order to meet requirements for applications in near-infrared astronomy and X-ray spectroscopy. The detector exploits a combined detection mechanism, in which avalanche quasiparticle multiplication and the supercurrent jointly produce a voltage response to a single absorbed photon via successive formation of a photon-induced and a current-induced normal hotspot in a narrow superconducting strip. The response time of the detector should increase with the photon energy providing energy resolution. Depending on the superconducting material and operation conditions, the cut-off wavelength for the single-photon detection regime varies from infrared waves to visible light. We simulated the performance of the background-limited infrared direct detector and X-ray photon counter utilizing the above mechanism. Low dark count rate and intrinsic low-frequency cut-off allow for realizing a background limited noise equivalent power of 10−20 W Hz−1/2 for a far-infrared direct detector exposed to 4-K background radiation. At low temperatures, the intrinsic response time of the counter is rather determined by diffusion of nonequilibrium electrons than by the rate of energy transfer to phonons. Therefore, thermal fluctuations do not hamper energy resolution of the X-ray photon counter that should be better than 10−3 for 6-keV photons. Comparison of new data obtained with a Nb based detector and previously reported results on NbN quantum detectors support our estimates of ultimate detector performance.

The European Physical Journal Applied Physics•Feb 27, 2003•48 citations

Superconducting single-photon and photon-number-resolving detectors

S. Jahanmirinejad

Detecting light of low intensity is a key requirement in many fields of scientific endeavor, including but not limited to quantum information science, astronomy and optical spectroscopy. In the past decade the progress in the technology of superconducting film has allowed the realization of a new type of detector based on ultrathin (4-5nm) and narrow (

•Jan 1, 2012•0 citations
We analyze the ultimate performance of a superconducting quantum detector in order to meet requirements for applications in near-infrared astronomy and X-ray spectroscopy. The detector exploits a combined detection mechanism, in which avalanche quasiparticle multiplication and the supercurrent jointly produce a voltage response to a single absorbed photon via successive formation of a photon-induced and a current-induced normal hotspot in a narrow superconducting strip. The response time of the detector should increase with the photon energy providing energy resolution. Depending on the superconducting material and operation conditions, the cut-off wavelength for the single-photon detection regime varies from infrared waves to visible light. We simulated the performance of the background-limited infrared direct detector and X-ray photon counter utilizing the above mechanism. Low dark count rate and intrinsic low-frequency cut-off allow for realizing a background limited noise equivalent power of 10−20 W Hz−1/2 for a far-infrared direct detector exposed to 4-K background radiation. At low temperatures, the intrinsic response time of the counter is rather determined by diffusion of nonequilibrium electrons than by the rate of energy transfer to phonons. Therefore, thermal fluctuations do not hamper energy resolution of the X-ray photon counter that should be better than 10−3 for 6-keV photons. Comparison of new data obtained with a Nb based detector and previously reported results on NbN quantum detectors support our estimates of ultimate detector performance.