Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Science China Information Sciences

Superconducting X-ray detectors

Can Hui Yang, Mengting Si, Lixing You

Published Jul 15, 2020• 12 citations
Publisher
DOI
10.1007/s11432-020-2932-8

Related papers

Superconducting Quantum Detector for Astronomy and X-Ray

Alexei D. Semenov, Heinz‐Wilhelm Hübers, Gregory N Gol'tsman +1 more

•Jan 1, 2001•0 citations

Superconducting Quantum Detector for Astronomy and X -Ray Spectroscopy

Alexei D. Semenov, Heinz‐Wilhelm Hübers, Gregory N Gol'tsman +1 more

Springer eBooks•Jan 1, 2002•0 citations

Superconducting Tunnel Junctions as Single Photon X-Ray Detectors.

Michael C. Gaidis

•Jan 1, 1994•7 citations

Synchrotron X-ray studies of superconducting qubit materials

Ignace Jarrige, Anjali Premkumar, Conan R. Weiland +13 more

Bulletin of the American Physical Society•Mar 4, 2020•0 citations

Superconducting Detectors

George H. Rieke

Cambridge University Press eBooks•Apr 30, 2021•1 citation

X-ray detection using a superconducting transition-edge sensor microcalorimeter with electrothermal feedback

K. D. Irwin, Gene C Hilton, David A. Wollman +1 more

We have developed a new type of x-ray detector based on a superconducting transition-edge thermometer operated near 100 mK. A superconducting quantum interference device is used to measure the current through the thermometer, and negative electrothermal feedback is used to improve the energy resolution and shorten the thermal time constant. We have used a detector mounted on a scanning electron microscope to measure the energy of titanium Kα (4.5 keV) fluorescence x rays with a resolution better than 14 eV full width at half-maximum. Using two other devices, we have measured an energy resolution for Joule heat pulses of 2.6 eV at 1 keV and 0.2 eV at 4 eV, the best reported for any calorimeter. An electrical noise equivalent power of 3×10−18 W/√Hz was also measured, suggesting the use of these detectors as infrared bolometers.

Applied Physics Letters•Sep 23, 1996•229 citations
We have developed a new type of x-ray detector based on a superconducting transition-edge thermometer operated near 100 mK. A superconducting quantum interference device is used to measure the current through the thermometer, and negative electrothermal feedback is used to improve the energy resolution and shorten the thermal time constant. We have used a detector mounted on a scanning electron microscope to measure the energy of titanium Kα (4.5 keV) fluorescence x rays with a resolution better than 14 eV full width at half-maximum. Using two other devices, we have measured an energy resolution for Joule heat pulses of 2.6 eV at 1 keV and 0.2 eV at 4 eV, the best reported for any calorimeter. An electrical noise equivalent power of 3×10−18 W/√Hz was also measured, suggesting the use of these detectors as infrared bolometers.