Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Science China Information Sciences

Superconducting X-ray detectors

Can Hui Yang, Mengting Si, Lixing You

Published Jul 15, 2020• 13 citations
Publisher
DOI
10.1007/s11432-020-2932-8

Related papers

Superconducting Quantum Detector for Astronomy and X-Ray

Alexei D. Semenov, Heinz‐Wilhelm Hübers, Gregory N Gol'tsman +1 more

•Jan 1, 2001•0 citations

Superconducting Quantum Detector for Astronomy and X -Ray Spectroscopy

Alexei D. Semenov, Heinz‐Wilhelm Hübers, Gregory N Gol'tsman +1 more

Springer eBooks•Jan 1, 2002•1 citation

Superconducting Tunnel Junctions as Single Photon X-Ray Detectors.

Michael C. Gaidis

•Jan 1, 1994•7 citations

Superconducting Detectors

George H. Rieke

Cambridge University Press eBooks•Apr 29, 2021•1 citation

X-ray detection using a superconducting transition-edge sensor microcalorimeter with electrothermal feedback

K. D. Irwin, Gene C Hilton, David A. Wollman +1 more

We have developed a new type of x-ray detector based on a superconducting transition-edge thermometer operated near 100 mK. A superconducting quantum interference device is used to measure the current through the thermometer, and negative electrothermal feedback is used to improve the energy resolution and shorten the thermal time constant. We have used a detector mounted on a scanning electron microscope to measure the energy of titanium Kα (4.5 keV) fluorescence x rays with a resolution better than 14 eV full width at half-maximum. Using two other devices, we have measured an energy resolution for Joule heat pulses of 2.6 eV at 1 keV and 0.2 eV at 4 eV, the best reported for any calorimeter. An electrical noise equivalent power of 3×10−18 W/√Hz was also measured, suggesting the use of these detectors as infrared bolometers.

Applied Physics Letters•Sep 23, 1996•259 citations

Ultimate performance of a superconducting quantum detector

Alexei D. Semenov, Andreas Engel, K. Ilin +3 more

We analyze the ultimate performance of a superconducting quantum detector in order to meet requirements for applications in near-infrared astronomy and X-ray spectroscopy. The detector exploits a combined detection mechanism, in which avalanche quasiparticle multiplication and the supercurrent jointly produce a voltage response to a single absorbed photon via successive formation of a photon-induced and a current-induced normal hotspot in a narrow superconducting strip. The response time of the detector should increase with the photon energy providing energy resolution. Depending on the superconducting material and operation conditions, the cut-off wavelength for the single-photon detection regime varies from infrared waves to visible light. We simulated the performance of the background-limited infrared direct detector and X-ray photon counter utilizing the above mechanism. Low dark count rate and intrinsic low-frequency cut-off allow for realizing a background limited noise equivalent power of 10−20 W Hz−1/2 for a far-infrared direct detector exposed to 4-K background radiation. At low temperatures, the intrinsic response time of the counter is rather determined by diffusion of nonequilibrium electrons than by the rate of energy transfer to phonons. Therefore, thermal fluctuations do not hamper energy resolution of the X-ray photon counter that should be better than 10−3 for 6-keV photons. Comparison of new data obtained with a Nb based detector and previously reported results on NbN quantum detectors support our estimates of ultimate detector performance.

The European Physical Journal Applied Physics•Feb 27, 2003•56 citations
We have developed a new type of x-ray detector based on a superconducting transition-edge thermometer operated near 100 mK. A superconducting quantum interference device is used to measure the current through the thermometer, and negative electrothermal feedback is used to improve the energy resolution and shorten the thermal time constant. We have used a detector mounted on a scanning electron microscope to measure the energy of titanium Kα (4.5 keV) fluorescence x rays with a resolution better than 14 eV full width at half-maximum. Using two other devices, we have measured an energy resolution for Joule heat pulses of 2.6 eV at 1 keV and 0.2 eV at 4 eV, the best reported for any calorimeter. An electrical noise equivalent power of 3×10−18 W/√Hz was also measured, suggesting the use of these detectors as infrared bolometers.
We analyze the ultimate performance of a superconducting quantum detector in order to meet requirements for applications in near-infrared astronomy and X-ray spectroscopy. The detector exploits a combined detection mechanism, in which avalanche quasiparticle multiplication and the supercurrent jointly produce a voltage response to a single absorbed photon via successive formation of a photon-induced and a current-induced normal hotspot in a narrow superconducting strip. The response time of the detector should increase with the photon energy providing energy resolution. Depending on the superconducting material and operation conditions, the cut-off wavelength for the single-photon detection regime varies from infrared waves to visible light. We simulated the performance of the background-limited infrared direct detector and X-ray photon counter utilizing the above mechanism. Low dark count rate and intrinsic low-frequency cut-off allow for realizing a background limited noise equivalent power of 10−20 W Hz−1/2 for a far-infrared direct detector exposed to 4-K background radiation. At low temperatures, the intrinsic response time of the counter is rather determined by diffusion of nonequilibrium electrons than by the rate of energy transfer to phonons. Therefore, thermal fluctuations do not hamper energy resolution of the X-ray photon counter that should be better than 10−3 for 6-keV photons. Comparison of new data obtained with a Nb based detector and previously reported results on NbN quantum detectors support our estimates of ultimate detector performance.