A Stern-Gerlach interferometer combines Stern-Gerlach deflecting magnets to reconstitute initially split beams, in such a way that an arbitrary initial spin state is recovered. Technical and fundamental limitations on the realizability of the device are derived.
In recent work a Stern-Gerlach interferometer (SGI) was considered in which a polarized beam of spin-(1/2 particles is split by a Stern-Gerlach apparatus into two partial beams, and then subsequent Stern-Gerlach deflecting magnets are used to reconstitute these two beams into one. In these studies it was shown that when such a coherent polarized beam passed through a SGI, some spin coherence is inevitably lost. In this regard, folk wisdom concerning irreversibility provides something of a guide to the present problem, since we all know that when Humpty-Dumpty had his great fall nobody could put him together again. In the present paper we consider the fate of our spin-(1/2 Humpty-Dumpty when a detector is present that is sensitive to the passage of particles along one trajectory, but not the other. It is not surprising that coherence is destroyed as soon as one is able to tell along which path the atom traveled. However, there seems to be no general agreement about the mechanism of coherence loss. Our conclusion is that the loss of coherence in measurements on quantum systems can always be traced to the dynamics of correlations between the measuring apparatus and the system being observed.
The Stern-Gerlach experiment (SGE) has been known for decades, but a complete theory that explains all facets of it remains enigmatic. In its classic realization, each spin state of an atom follows a unique path or trajectory in an SGE. The enigmatic part is the final output of SGE. Feynman envisaged the outcome to be an entangled state, a superposition of $|\text{spin}\phantom{\rule{4.pt}{0ex}}\text{state}\ensuremath{\rangle}\ensuremath{\bigotimes}|\text{corresponding}\phantom{\rule{4.pt}{0ex}}\text{path}\ensuremath{\rangle}$. Later works described the final state of SGE as a mixed state, a weighted average of states belonging to separate beams or trajectories. Notably, Schwinger, Englert, and Scully compared the difficulty of obtaining a coherent output (a pure state) to ``putting together Humpty Dumpty'' again. Yet recent experiments using Bose-Einstein condensates indicate the emerging beams are partly coherent, favoring Feynman's description. In this work, we revisit SGE using a recent version of the quantum master equation. We show that both outcomes are probable depending on the time of flight and the timescale of the environmental fluctuations. We predict the output is initially coherent and grows gradually into a mixed state. Moreover, we also estimate how the magnetic-field gradient helps broaden the beam waist. Moreover, our treatment implies that the wave function of an atom passing through a Stern-Gerlach device does not undergo an instantaneous collapse; rather, a gradual decay of coherences results in a mixed state, resulting in an irreversible process.
Abstract In 1921, Otto Stern conceived the idea for an experiment that would decide between a classical and a quantum description of atomic behavior, as epitomized by the Bohr–Sommerfeld–Debye model of the atom. This model entailed not only the quantization of the magnitude of the orbital electronic angular momentum but also of the projection of the angular momentum on an external magnetic field – the so‐called space quantization. Stern recognized that space quantization would have observable consequences: namely, that the magnetic dipole moment due to the orbital angular momentum would be space quantized as well, taking two opposite values for atoms whose only unpaired electron has just one quantum of orbital angular momentum. When acted upon by a suitable inhomogeneous magnetic field, a beam of such atoms would be split into two beams consisting of deflected atoms with opposite projections of the orbital angular momentum on the magnetic field. In contradistinction, if atoms behaved classically, the atomic beam would only broaden along the field gradient and have maximum intensity at zero deflection, i. e., where there would be a minimum or no intensity for a beam split due to space quantization. Stern anticipated that, although simple in principle, the experiment would be difficult to carry out – and invited Walther Gerlach to team up with him. Gerlach's realism and experimental skills together with his sometimes stubborn determination to make things work proved invaluable for the success of the Stern–Gerlach experiment (SGE). After a long struggle, Gerlach finally saw, on 8 February 1922, the splitting of a beam of silver atoms in a magnetic field. The absence of the concept of electron spin confused and confounded the interpretation of the SGE, as the silver atoms were, in fact, in a 2S state, with zero orbital and spin angular momentum. However, a key quantum feature whose existence the SGE was designed to test – namely space quantization of electronic angular momentum – was robust enough to transpire independent of whether the electronic angular momentum was orbital or due to spin. The SGE entails other key aspects of quantum mechanics such as quantum measurement, state preparation, coherence, and entanglement. Confronted with the outcome of the SGE, Stern noted: “I still have objections to the idea of beauty of quantum mechanics. But she is correct.”
The Stern-Gerlach effect, found a century ago, has become a paradigm of quantum mechanics. Unexpectedly, until recently, there has been little evidence that the original scheme with freely propagating atoms exposed to gradients from macroscopic magnets is a fully coherent quantum process. Several theoretical studies have explained why a Stern-Gerlach interferometer is a formidable challenge. Here, we provide a detailed account of the realization of a full-loop Stern-Gerlach interferometer for single atoms and use the acquired understanding to show how this setup may be used to realize an interferometer for macroscopic objects doped with a single spin. Such a realization would open the door to a new era of fundamental probes, including the realization of previously inaccessible tests at the interface of quantum mechanics and gravity.
The Stern-Gerlach effect, found a century ago, has become a paradigm of quantum mechanics. Unexpectedly, until recently, there has been little evidence that the original scheme with freely propagating atoms exposed to gradients from macroscopic magnets is a fully coherent quantum process. Several theoretical studies have explained why a Stern-Gerlach interferometer is a formidable challenge. Here, we provide a detailed account of the realization of a full-loop Stern-Gerlach interferometer for single atoms and use the acquired understanding to show how this setup may be used to realize an interferometer for macroscopic objects doped with a single spin. Such a realization would open the door to a new era of fundamental probes, including the realization of previously inaccessible tests at the interface of quantum mechanics and gravity.
The Stern-Gerlach (SG) effect, discovered almost a century ago, has become a paradigm of quantum mechanics. Surprisingly there is little evidence that the original scheme with freely propagating atoms exposed to gradients from macroscopic magnets is a fully coherent quantum process. Specifically, no high-visibility spatial interference pattern has been observed with such a scheme, and furthermore no full-loop SG interferometer has been realized with the scheme as envisioned decades ago. On the contrary, numerous theoretical studies explained why it is a near impossible endeavor. Here we demonstrate for the first time both a high-visibility spatial SG interference pattern and a full-loop SG interferometer, based on an accurate magnetic field, originating from an atom chip, that ensures coherent operation within strict constraints described by previous theoretical analyses. This also allows us to observe the gradual emergence of time-irreversibility as the splitting is increased. Finally, achieving this high level of control over magnetic gradients may facilitate technological applications such as large-momentum-transfer beam splitting for metrology with atom interferometry, ultra-sensitive probing of electron transport down to shot-noise and squeezed currents, as well as nuclear magnetic resonance and compact accelerators.