Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement of the coherent scattering length of gases with the neutron interferometer

Helmut Kaiser

Published Dec 1, 1978• 0 citations
OpenAlex

Related papers

Elucidation of the neutron coherence length and a matter-wave sideband interferometer

Robert Golub, S. K. Lamoreaux

Physics Letters A•Feb 1, 1992•43 citations

Measurement of neutron scattering lengths using neutron interferometry

Chandra Shahi

•Jan 1, 2016•1 citation

Coherent control of neutron interferometry

Dmitry A. Pushin

In this thesis, several novel techniques are proposed and demonstrated for measuring the coherent properties of materials and testing aspects of quantum information processing using a single crystal neutron interferometer. In particular we introduce methods for reciprocal space encoding of spatial information systematically in a neutron interferometer. First, a proof of principle experiment is conducted for coherent reciprocal space neutron imaging. This newly proposed technique overcomes the limitation of spacial resolution of current two dimensional neutron detectors. Second, an experiment to measure the vertical coherent length of a neutron interferometer is reported, which extends the previously achieved path separation. Third, we propose a new interferometry geometry that reduces the sensitivity of the neutron interferometer to environmental vibrational disturbances. The method is based on a quantum error compensating algorithm. Finally, a new method that is capable of measuring the autocorrelation function of a sample is proposed. This new technique can extend the capability of traditional neutron scattering experiments. All experiments are conducted at the neutron interferometry facility at the National Institute of Standards and Technology (NIST).

•Jan 1, 2006•7 citations

Measurements of the Vertical Coherence Length in Neutron Interferometry

Dmitry A. Pushin, M. Arif, M. G. Huber +1 more

The study and use of macroscopic quantum coherence requires long coherence lengths. Here we describe an approach to measuring the vertical coherence length in neutron interferometry, along with improvements to the NIST interferometer that led to a measured coherence length of 790 A. The measurement is based on introducing a path separation and measuring the loss in contrast as this separation is increased. The measured coherence length is consistent with the momentum distribution of the neutron beam. Finally, we demonstrate that the loss in contrast with beam displacement in one leg of the interferometer can be recovered by introducing a corresponding displacement in the second leg.

Physical Review Letters•Jun 26, 2008•40 citations

Neutron Interferometry

Jean-Louis Basdevant, Jean Dalibard

Springer eBooks•May 23, 2019•2 citations

Precision measurement of the bound-coherent-neutron scattering length of U235

M. Arif, Helmut Kaiser, S. Werner +1 more

With use of the neutron interferometric technique, the real parts of the bound-coherent scattering length, b, of $^{235}\mathrm{U}$ have been precisely measured for five different incident neutron energies in the range of 30 to 92 meV. The value of b at each incident neutron energy was obtained from the average of two independent measurements using two samples of different thicknesses. The results are b=10.47\ifmmode\pm\else\textpm\fi{}0.04 fm (E=30.34 meV), b=10.47\ifmmode\pm\else\textpm\fi{}0.03 fm (E=41.02 meV), b=10.51\ifmmode\pm\else\textpm\fi{}0.03 fm (E=51.43 meV), b=10.39\ifmmode\pm\else\textpm\fi{}0.03 fm (E=74.90 meV), b=10.41\ifmmode\pm\else\textpm\fi{}0.03 fm (E=91.39 meV). The uncertainty in these results is about an order of magnitude smaller than the present literature value. The small energy dependence of the observed scattering lengths has been used to establish the parameters of the negative energy resonance level (-1.4 eV) using the Breit-Wigner formalism.

Physical Review A•Apr 1, 1987•10 citations
In this thesis, several novel techniques are proposed and demonstrated for measuring the coherent properties of materials and testing aspects of quantum information processing using a single crystal neutron interferometer. In particular we introduce methods for reciprocal space encoding of spatial information systematically in a neutron interferometer. First, a proof of principle experiment is conducted for coherent reciprocal space neutron imaging. This newly proposed technique overcomes the limitation of spacial resolution of current two dimensional neutron detectors. Second, an experiment to measure the vertical coherent length of a neutron interferometer is reported, which extends the previously achieved path separation. Third, we propose a new interferometry geometry that reduces the sensitivity of the neutron interferometer to environmental vibrational disturbances. The method is based on a quantum error compensating algorithm. Finally, a new method that is capable of measuring the autocorrelation function of a sample is proposed. This new technique can extend the capability of traditional neutron scattering experiments. All experiments are conducted at the neutron interferometry facility at the National Institute of Standards and Technology (NIST).
The study and use of macroscopic quantum coherence requires long coherence lengths. Here we describe an approach to measuring the vertical coherence length in neutron interferometry, along with improvements to the NIST interferometer that led to a measured coherence length of 790 A. The measurement is based on introducing a path separation and measuring the loss in contrast as this separation is increased. The measured coherence length is consistent with the momentum distribution of the neutron beam. Finally, we demonstrate that the loss in contrast with beam displacement in one leg of the interferometer can be recovered by introducing a corresponding displacement in the second leg.
With use of the neutron interferometric technique, the real parts of the bound-coherent scattering length, b, of 235U^{235}\mathrm{U}235U have been precisely measured for five different incident neutron energies in the range of 30 to 92 meV. The value of b at each incident neutron energy was obtained from the average of two independent measurements using two samples of different thicknesses. The results are b=10.47\ifmmode\pm\else\textpm\fi{}0.04 fm (E=30.34 meV), b=10.47\ifmmode\pm\else\textpm\fi{}0.03 fm (E=41.02 meV), b=10.51\ifmmode\pm\else\textpm\fi{}0.03 fm (E=51.43 meV), b=10.39\ifmmode\pm\else\textpm\fi{}0.03 fm (E=74.90 meV), b=10.41\ifmmode\pm\else\textpm\fi{}0.03 fm (E=91.39 meV). The uncertainty in these results is about an order of magnitude smaller than the present literature value. The small energy dependence of the observed scattering lengths has been used to establish the parameters of the negative energy resonance level (-1.4 eV) using the Breit-Wigner formalism.