Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement of the coherent scattering length of gases with the neutron interferometer

Helmut Kaiser

Published Dec 1, 1978• 0 citations
OpenAlex

Related papers

Precisison neutron interferometric measurement of the nd coherent scattering length

William Michael Snow, T. Black, Muhammad Arif +6 more

APS•Nov 1, 2003•0 citations

Elucidation of the neutron coherence length and a matter-wave sideband interferometer

Robert Golub, S. K. Lamoreaux

Physics Letters A•Feb 1, 1992•39 citations

Measurement of neutron scattering lengths using neutron interferometry

Chandra Shahi

•Jan 1, 2016•1 citation

Precision measurement of the n-4He scattering length using neutron interferometry

M. G. Huber, Muhammad Arif, David L. Jacobson +5 more

Bulletin of the American Physical Society•Nov 6, 2010•0 citations

Measurement of Neutron Pair Correlations for Multiple Detectors in a Neutron Interferometer

David L. Jacobson, Brendan E. Allman, Samuel A. Werner +2 more

APS•May 1, 1996•0 citations

Measurements of the Vertical Coherence Length in Neutron Interferometry

Dmitry A. Pushin, M. Arif, M. G. Huber +1 more

The study and use of macroscopic quantum coherence requires long coherence lengths. Here we describe an approach to measuring the vertical coherence length in neutron interferometry, along with improvements to the NIST interferometer that led to a measured coherence length of 790 A. The measurement is based on introducing a path separation and measuring the loss in contrast as this separation is increased. The measured coherence length is consistent with the momentum distribution of the neutron beam. Finally, we demonstrate that the loss in contrast with beam displacement in one leg of the interferometer can be recovered by introducing a corresponding displacement in the second leg.

Physical Review Letters•Jun 26, 2008•30 citations
The study and use of macroscopic quantum coherence requires long coherence lengths. Here we describe an approach to measuring the vertical coherence length in neutron interferometry, along with improvements to the NIST interferometer that led to a measured coherence length of 790 A. The measurement is based on introducing a path separation and measuring the loss in contrast as this separation is increased. The measured coherence length is consistent with the momentum distribution of the neutron beam. Finally, we demonstrate that the loss in contrast with beam displacement in one leg of the interferometer can be recovered by introducing a corresponding displacement in the second leg.