Coherent control of neutron interferometry

Dmitry A. Pushin

Published Jan 1, 2006• 7 citations
OpenAlex

Abstract

In this thesis, several novel techniques are proposed and demonstrated for measuring the coherent properties of materials and testing aspects of quantum information processing using a single crystal neutron interferometer. In particular we introduce methods for reciprocal space encoding of spatial information systematically in a neutron interferometer. First, a proof of principle experiment is conducted for coherent reciprocal space neutron imaging. This newly proposed technique overcomes the limitation of spacial resolution of current two dimensional neutron detectors. Second, an experiment to measure the vertical coherent length of a neutron interferometer is reported, which extends the previously achieved path separation. Third, we propose a new interferometry geometry that reduces the sensitivity of the neutron interferometer to environmental vibrational disturbances. The method is based on a quantum error compensating algorithm. Finally, a new method that is capable of measuring the autocorrelation function of a sample is proposed. This new technique can extend the capability of traditional neutron scattering experiments. All experiments are conducted at the neutron interferometry facility at the National Institute of Standards and Technology (NIST).

Related papers

Neutron Interferometry at the National Institute of Standards and Technology

Dmitry A. Pushin, M. G. Huber, M. Arif +5 more

Neutron interferometry has proved to be a very precise technique for measuring the quantum mechanical phase of a neutron caused by a potential energy difference between two spatially separated neutron paths inside interferometer. The path length inside the interferometer can be many centimeters (and many centimeters apart) making it very practical to study a variety of samples, fields, potentials, and other macroscopic medium and quantum effects. The precision of neutron interferometry comes at a cost; neutron interferometers are very susceptible to environmental noise that is typically mitigated with large, active isolated enclosures. With recent advances in quantum information processing especially quantum error correction (QEC) codes we were able to demonstrate a neutron interferometer that is insensitive to vibrational noise. A facility at NIST’s Center for Neutron Research (NCNR) has just been commissioned with higher neutron flux than the NCNR’s older interferometer setup. This new facility is based on QEC neutron interferometer, thus improving the accessibility of neutron interferometry to the greater scientific community and expanding its applications to quantum computing, gravity, and material research.

Advances in High Energy Physics•Jan 1, 2015•27 citations

Quantum Information Enabled Neutron Interferometry

J. Nsofini

Neutron interferometry with its ability to encode and extract information provides a test bed for quantum mechanics and precise measurement of physical quantities of significant importance in physics. However, this significant key investigative technique is weakened by its very fragile nature; neutron interferometry has proven to be highly sensitive to environmental noise. Once brought to its optimal state, the use of neutron interferometry enabled with quantum information, represents a milestone. Indeed a realization of high-quality neutron interferometry could pave a way to probe materials research such as probing properties water in proteins and topological materials. Thus understanding and solving the sensitivity of neutron interferometers to noise is a key step toward possible applications. This is the core of the work done in this Thesis. We incorporated two theoretical techniques developed for quantum information sciences into the construction of a new polarized neutron interferometry beam line: The technique of quantum error correction and the technique of open quantum system. One focus of this work is to report on the design, the construction as well as the characteristic features of this beamline. This thesis involves experimental data, showing how the neutron beam intensity at the exit of a three-blade neutron interferometer can be controlled by the interferometer blades thickness. Secondly, is also presents an alternative and simplified quantum information approach to dynamical diffraction, based on repeated application of a coherent beam- splitting unitary at coarse-grained lattice sites. Demanding translational invariance added to a computationally tractable number of sites in the coarse-graining reproduced many results typical of standard dynamical diffraction theory and experiments. Building on that, a proposal for a new five-blade neutron interferometer is presented and its robustness to noise, resulting from dynamical diffraction together with low-frequency external mechanical vibration is discussed. Steps ahead in our work, neutron interferometry may be improved as well as adapted to more applications by incorporating the spin and orbital degrees of freedom to a path-based ivinterferometer. In this concern, we propose a method to prepare the spin-orbit state by passing a polarized neutron beam through a quadrupole magnetic field. Initially designed for a beam the size of a coherent length, we extend this method to work for spatially displaced beams by using linear magnetic gradients.

•Jun 12, 2017•1 citation

Structured Beams as Quantum Probes

Dusan Sarenac

This thesis describes several projects under the common theme of generating and manipulating the spatial quantum phase structure of matter and electromagnetic waves. Experiments dealing with the following topics are addressed: perfect crystal neutron interferometry, far-field phase-grating moire interferometry, orbital angular momentum (OAM), spin-orbit states, and lattices of spin-orbit states. The first focus of the thesis is describing the work related to the construction of a new beamline dedicated to quantum information related neutron interferometry experiments at the National Institute of Standards and Technology's Center for Neutron Research. This includes the development of the necessary environmental isolation, phase stability, and temperature isolation mechanisms; and the installation and optimization of spin polarization elements. The new beamline is now operational and it is currently one of only three neutron interferometry facilities in the world. The second focus of the thesis is to describe the development and characterization of far-field phase-grating moire neutron interferometry. This technique enables studies that are complimentary to those of perfect crystal neutron interferometry experiments. It may be used to probe structured materials and characterize neutron interactions with potential gradients. A two phase-grating moire neutron interferometer was developed, characterized, and optimized. This setup was then employed to probe the microstructure of a monodisperse suspension of 2 um diameter polystyrene spheres. Furthermore, a three phase-grating moire neutron interferometer was developed and characterized. This unique setup promises a wide range of impactful experiments from far-field imaging of material substructure to fundamental physics. The third focus of the thesis is to describe neutron OAM. These experiments revolve around the preparation and characterization of an azimuthally varying phase profile. The demonstration of neutron OAM using a perfect crystal neutron interferometer is described, where a spiral phase plate was used to induce OAM in one of the paths of the interferometer. Furthermore, a modified setup was used to perform neutron holography of a macroscopic object which induces an azimuthally varying phase profile. These methods provide a new tool for interferometric testing of neutron optics and the characterization of coherence of neutron beams. The last focus of the thesis is to describe matter wave and optical spin correlated OAM (spin-orbit) states. Methods to prepare neutron spin-orbit states via special geometries of magnetic fields are proposed. The preparation, entanglement characterization, and proposed experimental verification of such states are described in detail. Furthermore, a method which is capable of preparing lattices of optical and neutron spin-orbit states is introduced and described. This method utilizes novel optical and neutron devices and it is based on coherent averaging and spatial control methods borrowed from nuclear magnetic resonance. The experimental preparation and characterization of optical lattices of spin-orbit states is described in detail.

•Jun 15, 2018•2 citations

Decoherence-free neutron interferometry

Dmitry A. Pushin, M. Arif, David G. Cory

Perfect single-crystal neutron interferometers are adversely sensitive to environmental disturbances, particularly mechanical vibrations. The sensitivity to vibrations results from the slow velocity of thermal neutrons and the long measurement time that are encountered in a typical experiment. Consequently, to achieve a good interference solutions for reducing vibration other than those normally used in optical experiments must be explored. Here we introduce a geometry for a neutron interferometer that is less sensitive to low-frequency vibrations. This design may be compared with both dynamical decoupling methods and decoherence-free subspaces that are described in quantum information processing. By removing the need for bulky vibration isolation setups, this design will make it easier to adopt neutron interferometry to a wide range of applications and increase its sensitivity.

arXiv:1602.05938•Physical Review A•May 21, 2009•23 citations

Neutron interferometers and apparatus

Helmut Rauch, Samuel A. Werner

Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).

Oxford University Press eBooks•Aug 10, 2000•0 citations

Neutron Interferometer Experiments Studying Fundamental Features of Quantum Mechanics

Armin Danner, Hartmut Lemmel, Richard Wagner +2 more

Quantum theory provides us with the best account of microscopic components of matter as well as of radiation. It was introduced in the twentieth century and has experienced a wide range of success. Although the theory’s probabilistic predictions of final experimental outcomes is found to be correct with high precision, there is no general consensus regarding what is actually going on with a quantum system “en route”, or rather the perceivable intermediate behavior of a quantum system, e.g., the particle’s behavior in the double-slit experiment. Neutron interferometry using single silicon perfect crystals is established as a versatile tool to test fundamental phenomena in quantum mechanics, where an incident neutron beam is coherently split in two or three beam paths with macroscopic separation of several centimeters. Here, we present quantum optical experiments with these matter-wave interferometers, studying the effect of the quantum Cheshire Cat in some variants, the neutron’s presence in the paths of the interferometer as well as the direct test of a commutation relation. To reduce disturbances induced by the measurement, the interaction strength is lessened and so-called weak interactions are exploited by employing pre- and post-selection procedures. All results of the experiments confirm the predictions of quantum theory; the observed behaviors of the neutron between the pre- and post-selection in space and time emphasize striking and counter-intuitive aspects of quantum theory.

Atoms•Jun 15, 2023•12 citations
In this thesis, several novel techniques are proposed and demonstrated for measuring the coherent properties of materials and testing aspects of quantum information processing using a single crystal neutron interferometer. In particular we introduce methods for reciprocal space encoding of spatial information systematically in a neutron interferometer. First, a proof of principle experiment is conducted for coherent reciprocal space neutron imaging. This newly proposed technique overcomes the limitation of spacial resolution of current two dimensional neutron detectors. Second, an experiment to measure the vertical coherent length of a neutron interferometer is reported, which extends the previously achieved path separation. Third, we propose a new interferometry geometry that reduces the sensitivity of the neutron interferometer to environmental vibrational disturbances. The method is based on a quantum error compensating algorithm. Finally, a new method that is capable of measuring the autocorrelation function of a sample is proposed. This new technique can extend the capability of traditional neutron scattering experiments. All experiments are conducted at the neutron interferometry facility at the National Institute of Standards and Technology (NIST).
Neutron interferometry has proved to be a very precise technique for measuring the quantum mechanical phase of a neutron caused by a potential energy difference between two spatially separated neutron paths inside interferometer. The path length inside the interferometer can be many centimeters (and many centimeters apart) making it very practical to study a variety of samples, fields, potentials, and other macroscopic medium and quantum effects. The precision of neutron interferometry comes at a cost; neutron interferometers are very susceptible to environmental noise that is typically mitigated with large, active isolated enclosures. With recent advances in quantum information processing especially quantum error correction (QEC) codes we were able to demonstrate a neutron interferometer that is insensitive to vibrational noise. A facility at NIST’s Center for Neutron Research (NCNR) has just been commissioned with higher neutron flux than the NCNR’s older interferometer setup. This new facility is based on QEC neutron interferometer, thus improving the accessibility of neutron interferometry to the greater scientific community and expanding its applications to quantum computing, gravity, and material research.
Neutron interferometry with its ability to encode and extract information provides a test bed for quantum mechanics and precise measurement of physical quantities of significant importance in physics. However, this significant key investigative technique is weakened by its very fragile nature; neutron interferometry has proven to be highly sensitive to environmental noise. Once brought to its optimal state, the use of neutron interferometry enabled with quantum information, represents a milestone. Indeed a realization of high-quality neutron interferometry could pave a way to probe materials research such as probing properties water in proteins and topological materials. Thus understanding and solving the sensitivity of neutron interferometers to noise is a key step toward possible applications. This is the core of the work done in this Thesis. We incorporated two theoretical techniques developed for quantum information sciences into the construction of a new polarized neutron interferometry beam line: The technique of quantum error correction and the technique of open quantum system. One focus of this work is to report on the design, the construction as well as the characteristic features of this beamline. This thesis involves experimental data, showing how the neutron beam intensity at the exit of a three-blade neutron interferometer can be controlled by the interferometer blades thickness. Secondly, is also presents an alternative and simplified quantum information approach to dynamical diffraction, based on repeated application of a coherent beam- splitting unitary at coarse-grained lattice sites. Demanding translational invariance added to a computationally tractable number of sites in the coarse-graining reproduced many results typical of standard dynamical diffraction theory and experiments. Building on that, a proposal for a new five-blade neutron interferometer is presented and its robustness to noise, resulting from dynamical diffraction together with low-frequency external mechanical vibration is discussed. Steps ahead in our work, neutron interferometry may be improved as well as adapted to more applications by incorporating the spin and orbital degrees of freedom to a path-based ivinterferometer. In this concern, we propose a method to prepare the spin-orbit state by passing a polarized neutron beam through a quadrupole magnetic field. Initially designed for a beam the size of a coherent length, we extend this method to work for spatially displaced beams by using linear magnetic gradients.
This thesis describes several projects under the common theme of generating and manipulating the spatial quantum phase structure of matter and electromagnetic waves. Experiments dealing with the following topics are addressed: perfect crystal neutron interferometry, far-field phase-grating moire interferometry, orbital angular momentum (OAM), spin-orbit states, and lattices of spin-orbit states. The first focus of the thesis is describing the work related to the construction of a new beamline dedicated to quantum information related neutron interferometry experiments at the National Institute of Standards and Technology's Center for Neutron Research. This includes the development of the necessary environmental isolation, phase stability, and temperature isolation mechanisms; and the installation and optimization of spin polarization elements. The new beamline is now operational and it is currently one of only three neutron interferometry facilities in the world. The second focus of the thesis is to describe the development and characterization of far-field phase-grating moire neutron interferometry. This technique enables studies that are complimentary to those of perfect crystal neutron interferometry experiments. It may be used to probe structured materials and characterize neutron interactions with potential gradients. A two phase-grating moire neutron interferometer was developed, characterized, and optimized. This setup was then employed to probe the microstructure of a monodisperse suspension of 2 um diameter polystyrene spheres. Furthermore, a three phase-grating moire neutron interferometer was developed and characterized. This unique setup promises a wide range of impactful experiments from far-field imaging of material substructure to fundamental physics. The third focus of the thesis is to describe neutron OAM. These experiments revolve around the preparation and characterization of an azimuthally varying phase profile. The demonstration of neutron OAM using a perfect crystal neutron interferometer is described, where a spiral phase plate was used to induce OAM in one of the paths of the interferometer. Furthermore, a modified setup was used to perform neutron holography of a macroscopic object which induces an azimuthally varying phase profile. These methods provide a new tool for interferometric testing of neutron optics and the characterization of coherence of neutron beams. The last focus of the thesis is to describe matter wave and optical spin correlated OAM (spin-orbit) states. Methods to prepare neutron spin-orbit states via special geometries of magnetic fields are proposed. The preparation, entanglement characterization, and proposed experimental verification of such states are described in detail. Furthermore, a method which is capable of preparing lattices of optical and neutron spin-orbit states is introduced and described. This method utilizes novel optical and neutron devices and it is based on coherent averaging and spatial control methods borrowed from nuclear magnetic resonance. The experimental preparation and characterization of optical lattices of spin-orbit states is described in detail.
Perfect single-crystal neutron interferometers are adversely sensitive to environmental disturbances, particularly mechanical vibrations. The sensitivity to vibrations results from the slow velocity of thermal neutrons and the long measurement time that are encountered in a typical experiment. Consequently, to achieve a good interference solutions for reducing vibration other than those normally used in optical experiments must be explored. Here we introduce a geometry for a neutron interferometer that is less sensitive to low-frequency vibrations. This design may be compared with both dynamical decoupling methods and decoherence-free subspaces that are described in quantum information processing. By removing the need for bulky vibration isolation setups, this design will make it easier to adopt neutron interferometry to a wide range of applications and increase its sensitivity.
Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).
Quantum theory provides us with the best account of microscopic components of matter as well as of radiation. It was introduced in the twentieth century and has experienced a wide range of success. Although the theory’s probabilistic predictions of final experimental outcomes is found to be correct with high precision, there is no general consensus regarding what is actually going on with a quantum system “en route”, or rather the perceivable intermediate behavior of a quantum system, e.g., the particle’s behavior in the double-slit experiment. Neutron interferometry using single silicon perfect crystals is established as a versatile tool to test fundamental phenomena in quantum mechanics, where an incident neutron beam is coherently split in two or three beam paths with macroscopic separation of several centimeters. Here, we present quantum optical experiments with these matter-wave interferometers, studying the effect of the quantum Cheshire Cat in some variants, the neutron’s presence in the paths of the interferometer as well as the direct test of a commutation relation. To reduce disturbances induced by the measurement, the interaction strength is lessened and so-called weak interactions are exploited by employing pre- and post-selection procedures. All results of the experiments confirm the predictions of quantum theory; the observed behaviors of the neutron between the pre- and post-selection in space and time emphasize striking and counter-intuitive aspects of quantum theory.