Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Optics

All acousto-optic modulator laser system for a 12 m fountain-type dual-species atom interferometer

Chuan He, Sitong Yan, Lin Zhou, Sachin Barthwal, Rundong Xu, Chao Zhou, Yu-Hang Ji, Qi Wang, Zhuo Hou, Jin Wang, Mingsheng Zhan

Published Jun 10, 2021• 5 citations
Publisher

Abstract

We design and implement a laser system for 85 R b and 87 R b dual-species atom interferometers based on acousto-optic frequency shift and tapered amplifier laser technologies. We use eight-pass acousto-optic modulators to generate repumping lasers for 85 R b and 87 R b atoms. The maximum frequency shift of the laser is 2.8 GHz, and the diffraction efficiency is higher than 20%. We use high-frequency acousto-optic modulators to generate the Raman lasers. This laser system uses only two seed lasers to provide the various frequencies required by 85 R b and 87 R b dual-species atom interferometers, which greatly improves laser usage. The laser system is applied in the equivalence principle test experiment using an 85 R b and 87 R b dual-species atom interferometer. The signal of atoms launched to 12 meters is successfully observed, and the resolution of gravity differential measurement is improved from 8 × 10 − 9 g to 1 × 10 − 10 g .

DOI
10.1364/ao.429965

Related papers

A compact laser system for a portable atom interferometry gravimeter

Qin Luo, Heng Zhang, Ke Zhang +4 more

A compact laser system for a portable 87Rb atom interferometry gravimeter has been demonstrated in this work. This laser system is based on frequency doubling of a single seed laser at the wavelength of 1560 nm. The frequency of the seed laser is controlled by a digital unit with an analog feedback circuit. By using this frequency control method, the frequency of the laser system can be shifted over 1 GHz. Based on this method, the Raman frequency can be locked on the F = 3 → F′ = 4 transition of 85Rb atoms. Moreover, the Raman sideband and the repumping laser are generated by a phase modulator, and it can generate different laser frequencies to meet the requirements of a typical atom interferometer. Additional sidebands in the Raman beam produced from the phase modulator are optimized and reduced, allowing us to observe atom interference with a free evolution time of 320 ms. The control unit including the laser system has been integrated into a box with a volume of 1.5 m × 0.6 m × 0.6 m, and the weight of which is only 150 kg. Using this compact optical scheme, our atomic gravimeter has achieved a sensitivity of 53 μGal/Hz1/2 and a resolution of better than 1 μGal (1 μGal = 1 × 10−8 m/s2) in an integration time of 3000 s.

Review of Scientific Instruments•Apr 1, 2019•47 citations

同位素原子饱和吸收谱稳频的拉曼激光方案

王玉平 WANG Yuping, 朱磊 ZHU Lei, 仲嘉琪 ZHONG Jiaqi +3 more

Atom interferometers based on the matter wave interferometry are promising tools for precision measurements. In laboratory, they have been used in the field of fundamental physics research. An important research effort is going on to miniaturize them, which can help to make them play a key role in resource exploration, inertial navigation and gravity mapping from space. The miniaturization of a laser system is a key link to miniaturize an atom interferometer. However, because the atoms used for the frequency stabilization in the existing schemes of the Raman laser system and the atoms used as the test masses in the atom interferometers are of the same type, the special optical elements and their driving devices are used to obtain the far detuning of the Raman lasers by frequency offset locking method, which makes the laser system complex and affects its reliability. Meanwhile, the increase in weight and cost of the laser system is adverse to apply them in the field of inertial navigation and space application. For an atom interferometer using one type of Rb isotope atoms as test mass, a frequency-stabilized Raman laser system based on another type of Rb isotope atoms saturated absorption spectrum is proposed to make the laser system for an atom interferometer compact and robust. This Raman laser system is helpful to miniaturize the laser systems of atom interferometers, and promotes the atom interferometers to be applied in movable platforms or in the weight-sensitive fields.For an 85Rb atom interferometer, the frequency-stabilized Raman laser system based on 87Rb atom saturated absorption spectrum is proposed to make the laser system compact and robust. First, the schematic of the stabilizing frequency and detuning of Raman laser is introduced. Second, the frequency-stabilized Raman laser system based on 87Rb atom saturated absorption spectrum is proposed. In this Raman laser system, the frequency of the Raman laser is stabilized to the 87Rb atom saturated spectrum to obtain the far detuning. Then, the laser beam from the Raman laser is modulated by an electro-optic modulator with driving frequency of 3.04 GHz. Amplified by a tapered amplifier, the carrier and +1st bandside in modulated laser beams are used as the Raman beams.The frequency stabilization experiment is done. By scanning the injection current and the voltage of the piezoelectric transducer of the Raman laser, the Rb saturated absorption spectrums are obtained. The frequency of the Raman laser is stabilized to the peak of 87Rb atomF=2→F'=CO2,3transition of D2 line, obtaining a red detuning of a magnitude of GHz and a linewidth of 80 kHz. The Raman beams generated by this Raman laser system are used to one atom interferometer of the atom gradiometer to evaluate its performance. The sensitivity of the atom interferometer using this Raman beams is 345 μGal/Hz1/2 with the interference fringe contrast of 20%. And the Allan deviation of the gravity measurement more than one day shows that the resolution of the atom interferometer is 2×10-8 g@7 500 s. It is calculated that the noise of the gravity measurement per shot contributed by the frequency noise of the Raman laser beams is less than 1 μGal.This Raman laser system uses an electro-optic modulator to generate a Raman beams, which inherits the advantages of the existing Raman schemes based on an electro-optic modulator. In this Raman laser system, a Rb cell is used as a substitute for an acousto-optic or electro-optic modulator to stabilize the frequency of the Raman laser and obtain the far detuning, which not only simplifies the light path and electric circuit of the Raman laser system, but also improves the reliability and long-term stability of the Raman beams. Both the atom interference experiment in the atom interferometer and the theoretical evaluation show that this Raman laser system is able to meet the miniaturized atom interferometers applied requirements. This Raman laser system is helpful to realize the miniaturization and weight reduction of the laser systems and promotes the atom interferometers to be applied in the movable platforms and in space.

ACTA PHOTONICA SINICA•Jan 1, 2024•1 citation

Test of Equivalence Principle at 1 0 − 8 Level by a Dual-Species Double-Diffraction Raman Atom Interferometer

Lin Zhou, Shitong Long, Biao Tang +9 more

We report an improved test of the weak equivalence principle by using a simultaneous $^{85}\mathrm{Rb}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ dual-species atom interferometer. We propose and implement a four-wave double-diffraction Raman transition scheme for the interferometer, and demonstrate its ability in suppressing common-mode phase noise of Raman lasers after their frequencies and intensity ratios are optimized. The statistical uncertainty of the experimental data for E\"otv\"os parameter $\ensuremath{\eta}$ is $0.8\ifmmode\times\else\texttimes\fi{}1{0}^{\ensuremath{-}8}$ at 3200 s. With various systematic errors corrected, the final value is $\ensuremath{\eta}=(2.8\ifmmode\pm\else\textpm\fi{}3.0)\ifmmode\times\else\texttimes\fi{}1{0}^{\ensuremath{-}8}$. The major uncertainty is attributed to the Coriolis effect.

arXiv:1503.00401•Physical Review Letters•Jul 2, 2015•352 citations

Injection locking of Raman laser beams in cold atom interferometers

Ling Wang, Yao Zhanwei, Xiong Zong-yuan +3 more

Raman pulse sequences are generally used to coherently manipulate the atomic wave packet in an atom interferometer.High power Raman beams allow more atoms join in the velocity-sensitive stimulated Raman transition,and that will be helpful for obtaining high signal to noise ratio in atom interferometer fringe.Development of high power Raman laser is important for cold atom interferometer experiments.The experimental realization of high power Raman lasers are demonstrated based on injection locking technique. Master laser is modulated by a 1.5 GHz acousto-optical modulator,and the±1 order diffraction lights are used as seeding Raman lasers.The seeding lasers are injection locked to two slave lasers which are further amplified as Raman beams.The frequency difference of Raman beams is 3.0 GHz,and the detuning range is about 200 MHz.

Chinese Journal of Quantum Electronics•Jan 1, 2012•0 citations

A modified Michelson interferometer type Raman laser system for atom interferometers

Ningfang Song, Xiangxiang Lu, Wei Li +5 more

We have developed a modified Michelson interferometer type Raman laser system to manipulate cold 87 Rb atoms to interfere. A frequency modulated continuous wave technique was introduced to determine the optical path difference, thus compensating it to zero to minimize the effects of common mode noise. The linewidth (full width at half maximum) of the beat signal at 6.834 GHz was measured to 1Hz limited by the resolution bandwidth of the spectral analyzer. The measured rms phase variance of the phase noise at 166 MHz was 0.015 rad2, mainly restricted by our poor performance radio frequency microwave source. With modest improvements, we plan to apply this laser system to form an atom interferometer for acceleration and rotation measurements.

arXiv:1407.4013•Jul 15, 2014•0 citations

Serrodyne Matterwave Optics

Jack Roth, Madeline Bernstein, Andrew Christensen +4 more

Bragg diffraction for atom interferometry conventionally requires two laser frequencies whose difference makes the two-photon transition resonant. We show that this frequency difference can instead be generated by serrodyne modulation, allowing Bragg pulses to be driven with a single-frequency laser. The serrodyne modulation is performed using an acousto-optic modulator driven with a phase-modulated RF drive, and generated kilohertz-scale frequency shifts on top of the AOM carrier frequency. While in general serrodyne modulation generates strong unwanted frequency components, we find conditions so that the Bragg diffraction pulses, and atom interferometers constructed from them, are robust to these imperfections, opening the door to the development of ultra compact, single frequency Bragg diffraction based atom interferometers with serrodyne modulation implemented by a position modulated retroreflection mirror.

arXiv:2607.24511•Jul 27, 2026•0 citations
We design and implement a laser system for 85 R b and 87 R b dual-species atom interferometers based on acousto-optic frequency shift and tapered amplifier laser technologies. We use eight-pass acousto-optic modulators to generate repumping lasers for 85 R b and 87 R b atoms. The maximum frequency shift of the laser is 2.8 GHz, and the diffraction efficiency is higher than 20%. We use high-frequency acousto-optic modulators to generate the Raman lasers. This laser system uses only two seed lasers to provide the various frequencies required by 85 R b and 87 R b dual-species atom interferometers, which greatly improves laser usage. The laser system is applied in the equivalence principle test experiment using an 85 R b and 87 R b dual-species atom interferometer. The signal of atoms launched to 12 meters is successfully observed, and the resolution of gravity differential measurement is improved from 8 × 10 − 9 g to 1 × 10 − 10 g .
A compact laser system for a portable 87Rb atom interferometry gravimeter has been demonstrated in this work. This laser system is based on frequency doubling of a single seed laser at the wavelength of 1560 nm. The frequency of the seed laser is controlled by a digital unit with an analog feedback circuit. By using this frequency control method, the frequency of the laser system can be shifted over 1 GHz. Based on this method, the Raman frequency can be locked on the F = 3 → F′ = 4 transition of 85Rb atoms. Moreover, the Raman sideband and the repumping laser are generated by a phase modulator, and it can generate different laser frequencies to meet the requirements of a typical atom interferometer. Additional sidebands in the Raman beam produced from the phase modulator are optimized and reduced, allowing us to observe atom interference with a free evolution time of 320 ms. The control unit including the laser system has been integrated into a box with a volume of 1.5 m × 0.6 m × 0.6 m, and the weight of which is only 150 kg. Using this compact optical scheme, our atomic gravimeter has achieved a sensitivity of 53 μGal/Hz1/2 and a resolution of better than 1 μGal (1 μGal = 1 × 10−8 m/s2) in an integration time of 3000 s.
Atom interferometers based on the matter wave interferometry are promising tools for precision measurements. In laboratory, they have been used in the field of fundamental physics research. An important research effort is going on to miniaturize them, which can help to make them play a key role in resource exploration, inertial navigation and gravity mapping from space. The miniaturization of a laser system is a key link to miniaturize an atom interferometer. However, because the atoms used for the frequency stabilization in the existing schemes of the Raman laser system and the atoms used as the test masses in the atom interferometers are of the same type, the special optical elements and their driving devices are used to obtain the far detuning of the Raman lasers by frequency offset locking method, which makes the laser system complex and affects its reliability. Meanwhile, the increase in weight and cost of the laser system is adverse to apply them in the field of inertial navigation and space application. For an atom interferometer using one type of Rb isotope atoms as test mass, a frequency-stabilized Raman laser system based on another type of Rb isotope atoms saturated absorption spectrum is proposed to make the laser system for an atom interferometer compact and robust. This Raman laser system is helpful to miniaturize the laser systems of atom interferometers, and promotes the atom interferometers to be applied in movable platforms or in the weight-sensitive fields.For an 85Rb atom interferometer, the frequency-stabilized Raman laser system based on 87Rb atom saturated absorption spectrum is proposed to make the laser system compact and robust. First, the schematic of the stabilizing frequency and detuning of Raman laser is introduced. Second, the frequency-stabilized Raman laser system based on 87Rb atom saturated absorption spectrum is proposed. In this Raman laser system, the frequency of the Raman laser is stabilized to the 87Rb atom saturated spectrum to obtain the far detuning. Then, the laser beam from the Raman laser is modulated by an electro-optic modulator with driving frequency of 3.04 GHz. Amplified by a tapered amplifier, the carrier and +1st bandside in modulated laser beams are used as the Raman beams.The frequency stabilization experiment is done. By scanning the injection current and the voltage of the piezoelectric transducer of the Raman laser, the Rb saturated absorption spectrums are obtained. The frequency of the Raman laser is stabilized to the peak of 87Rb atomF=2→F'=CO2,3transition of D2 line, obtaining a red detuning of a magnitude of GHz and a linewidth of 80 kHz. The Raman beams generated by this Raman laser system are used to one atom interferometer of the atom gradiometer to evaluate its performance. The sensitivity of the atom interferometer using this Raman beams is 345 μGal/Hz1/2 with the interference fringe contrast of 20%. And the Allan deviation of the gravity measurement more than one day shows that the resolution of the atom interferometer is 2×10-8 g@7 500 s. It is calculated that the noise of the gravity measurement per shot contributed by the frequency noise of the Raman laser beams is less than 1 μGal.This Raman laser system uses an electro-optic modulator to generate a Raman beams, which inherits the advantages of the existing Raman schemes based on an electro-optic modulator. In this Raman laser system, a Rb cell is used as a substitute for an acousto-optic or electro-optic modulator to stabilize the frequency of the Raman laser and obtain the far detuning, which not only simplifies the light path and electric circuit of the Raman laser system, but also improves the reliability and long-term stability of the Raman beams. Both the atom interference experiment in the atom interferometer and the theoretical evaluation show that this Raman laser system is able to meet the miniaturized atom interferometers applied requirements. This Raman laser system is helpful to realize the miniaturization and weight reduction of the laser systems and promotes the atom interferometers to be applied in the movable platforms and in space.
We report an improved test of the weak equivalence principle by using a simultaneous $^{85}\mathrm{Rb}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ dual-species atom interferometer. We propose and implement a four-wave double-diffraction Raman transition scheme for the interferometer, and demonstrate its ability in suppressing common-mode phase noise of Raman lasers after their frequencies and intensity ratios are optimized. The statistical uncertainty of the experimental data for E\"otv\"os parameter $\ensuremath{\eta}$ is $0.8\ifmmode\times\else\texttimes\fi{}1{0}^{\ensuremath{-}8}$ at 3200 s. With various systematic errors corrected, the final value is $\ensuremath{\eta}=(2.8\ifmmode\pm\else\textpm\fi{}3.0)\ifmmode\times\else\texttimes\fi{}1{0}^{\ensuremath{-}8}$. The major uncertainty is attributed to the Coriolis effect.
Raman pulse sequences are generally used to coherently manipulate the atomic wave packet in an atom interferometer.High power Raman beams allow more atoms join in the velocity-sensitive stimulated Raman transition,and that will be helpful for obtaining high signal to noise ratio in atom interferometer fringe.Development of high power Raman laser is important for cold atom interferometer experiments.The experimental realization of high power Raman lasers are demonstrated based on injection locking technique. Master laser is modulated by a 1.5 GHz acousto-optical modulator,and the±1 order diffraction lights are used as seeding Raman lasers.The seeding lasers are injection locked to two slave lasers which are further amplified as Raman beams.The frequency difference of Raman beams is 3.0 GHz,and the detuning range is about 200 MHz.
We have developed a modified Michelson interferometer type Raman laser system to manipulate cold 87 Rb atoms to interfere. A frequency modulated continuous wave technique was introduced to determine the optical path difference, thus compensating it to zero to minimize the effects of common mode noise. The linewidth (full width at half maximum) of the beat signal at 6.834 GHz was measured to 1Hz limited by the resolution bandwidth of the spectral analyzer. The measured rms phase variance of the phase noise at 166 MHz was 0.015 rad2, mainly restricted by our poor performance radio frequency microwave source. With modest improvements, we plan to apply this laser system to form an atom interferometer for acceleration and rotation measurements.
Bragg diffraction for atom interferometry conventionally requires two laser frequencies whose difference makes the two-photon transition resonant. We show that this frequency difference can instead be generated by serrodyne modulation, allowing Bragg pulses to be driven with a single-frequency laser. The serrodyne modulation is performed using an acousto-optic modulator driven with a phase-modulated RF drive, and generated kilohertz-scale frequency shifts on top of the AOM carrier frequency. While in general serrodyne modulation generates strong unwanted frequency components, we find conditions so that the Bragg diffraction pulses, and atom interferometers constructed from them, are robust to these imperfections, opening the door to the development of ultra compact, single frequency Bragg diffraction based atom interferometers with serrodyne modulation implemented by a position modulated retroreflection mirror.