Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement of short range forces using a cold atom interferometer

Sophie Pelisson, X. Wang

Published Jun 1, 2010• 0 citations
OpenAlex

Related papers

Measurement of short range forces using trapped cold atoms

Franck Pereira dos Santos, Peter Wolf, Arnaud Landragin +7 more

•Oct 5, 2008•0 citations

Short range force sensing with a trapped atom interferometer

Franck Pereira dos Santos, Yann Balland, Luc Absil

•Feb 13, 2023•0 citations

Contrast decay in a trapped-atom interferometer

Adèle Hilico, Cyrille Solaro, Min-Kang Zhou +2 more

A Ramsey-Raman interferometer is used to realize a compact force sensor using cold $^{87}\mathrm{Rb}$ atoms trapped in a vertical optical lattice. The sensitivity and accuracy of the force measurements are discussed and the limits in short-term sensitivity evaluated. We reach a relative sensitivity on the Bloch frequency and thus on the gravity acceleration of $3.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ at 1 s. We perform an experimental study of the influence of the transverse confinement onto the decay of the interferometer contrast and compare the measurements with a simple semiclassical model. It is shown that vertical gradients of the trapping potential can contribute significantly to the loss of contrast.

Physical Review A•May 18, 2015•22 citations

Cold atom interferometers and their applications in precision measurements

Jin Wang, Lin Zhou, Runbing Li +2 more

物理学前沿:英文版•Jun 1, 2009•17 citations

High-sensitivity cold-atom gyroscope with real-time vibration compensation

Denis Savoie, Matteo Altorio, Bess Fang +2 more

Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

Experiments on the reflection of cold atoms from magnetic thin films: From atom optics to measurement of short-range forces

Ashok Kumar Mohapatra, Saptarishi Chaudhuri, Sanjukta Roy +1 more

The European Physical Journal D•Feb 16, 2007•4 citations
A Ramsey-Raman interferometer is used to realize a compact force sensor using cold 87Rb^{87}\mathrm{Rb}87Rb atoms trapped in a vertical optical lattice. The sensitivity and accuracy of the force measurements are discussed and the limits in short-term sensitivity evaluated. We reach a relative sensitivity on the Bloch frequency and thus on the gravity acceleration of $3.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ at 1 s. We perform an experimental study of the influence of the transverse confinement onto the decay of the interferometer contrast and compare the measurements with a simple semiclassical model. It is shown that vertical gradients of the trapping potential can contribute significantly to the loss of contrast.