Measurement of standard vacuum noise at low frequencies

Xue Jia, Qin Ji-Liang, Yuchi Zhang, Gang Li, Zhang Peng-Fei, Tiancai Zhang, Kunchi Peng

Published Jan 1, 2016• 8 citations
Publisher

Abstract

Vacuum fluctuation at audio frequencies is very important and interesting in many research fields, such as the gravitational wave detection, ultra-weak magnetic field measurement, and the research of quantum metrology, etc. Since the generation of squeezed light in 1985, most of the squeezed light have been generated and measured at radio frequencies (~MHz) as there has not been much technical noise at higher frequencies. In the Michelson-interferometer-based gravitational wave detection, the detection band has frequencies from a few to tens of thousands Hz. Measuring vacuum noise at such low frequencies is a challenge since we have to stabilize and control all the audio noises and the interferences from a variety of mechanical and electronic noises, therefore a very high classical noise suppression is needed when the measurement time increases. In order to measure the squeezed light of low frequencies, the standard vacuum noise at audio frequencies must be measured. In this paper, a balanced homodyne detection system for measuring the low-frequency quantum vacuum noises is reported. It is not trivial to extend the detected frequency to very low analysis frequencies. Through a self-made self-subtraction balanced homodyne configuration, which can eliminate the DC component of each photocurrent from the photodiode and the classical common-mode technical noise, the standard vacuum noise has been detected. The linearity of the vacuum noise power has been validated by varying the local oscillator power, showing that the saturation power of light incidence is about 3.2 mW. When the incident-light power is 400 W, the standard vacuum noise is 11 dB higher than the electronic noise at 80 Hz. In the regime of about 80 Hz to 400 kHz, the linearity of the standard noise power as a function of incident laser power is verified. However, when the measurement is carried out at even lower frequencies, for example, 50 Hz, we may encounter some excess and non-stationary noises and find that the measured noise power is not proportional to the incident light power any more. These non-stationary noises are the main technical obstacle at low frequencies. The average common mode rejection ratio in the test frequency range from 10 Hz to 400 kHz is 55 dB and its maximum 63 dB at 100 Hz is obtained, implying a high suppression of the technical noise. This self-made homodyne vacuum noise detector can be widely used for precision measurement in quantum metrology and quantum optics.

DOI
10.7498/aps.65.044211

Related papers

Balanced homodyne detection of optical quantum states at audio-band frequencies and below

M S Stefszky, C M Mow-Lowry, S. Chua +7 more

The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.

arXiv:1205.3229•Classical and Quantum Gravity•Jun 25, 2012•127 citations

Balanced Homodyne Detection of Optical Quantum States at Audio-Band Frequencies and Below

Michael Stefszky, Conor M Mow-Lowry, S. Chua +7 more

The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.

•Jan 1, 2012•67 citations

Low Noise Balanced Homodyne Detector for Quantum Noise Measurement

Shubo Lang, Shicheng Zhang, Xiaolin Li +2 more

The research of quantum noise in the interaction of laser and atoms plays a critical role in quantum optical experiments. The measurement of quantum noise is mainly based on the balanced homodyne detection method. Here, we reported a balanced homodyne detector with low noise, high gain, and high common-mode rejection ratio (CMRR) at the wavelength of 795 nm. By optimizing the selection of components and printed circuit board (PCB) layout, a minimum electronic noise of −96.7 dBm is obtained. Over the range of 1 MHz to 5 MHz, we get a flat CMRR above 59 dB and a linear gain regime, which can enable a shot noise measurement with the laser power of$100~\mu \text{w}$. The developed detector can be used in quantum coherent experiments with a weak probe laser of power down to tens of microwatts.

IEEE Access•Jan 1, 2022•4 citations

Generation and Measurement of Squeezed Vacuum States at Audio-Band Frequencies

Yinghao Gao, Jinxia Feng, Yuanji Li +1 more

Squeezed vacuum states at audio-band frequencies are important quantum resources for practical applications. We demonstrated the generation of squeezed vacuum states at the audio-band frequencies from a subthreshold optical parametric oscillator with a periodically poled KTiOPO4 crystal pumped by a homemade continuous wave single-frequency dual-wavelength laser. To detect squeezed vacuum states at audio-band frequencies, the influences of the local oscillator (LO) power, the common mode rejection ratio (CMRR) of balanced homodyne detectors, and the phase jitter between the LO and squeezed vacuum field on the measurement of squeezed vacuum states at audio-band frequencies were considered. By optimizing the LO power, improving the CMRR of photodetectors to 67 dB based on the design of differential fine-tuning circuit and adjustable bias voltage, and reducing the phase jitter between the LO and squeezed vacuum field to 1.7° with the help of the coherent locking technique, 6.1 ± 0.3 dB squeezed vacuum states at audio frequencies from 5 kHz to 20 kHz were generated. A 3.0 ± 0.3 dB phase squeezed vacuum state was obtained at the audio frequency of 3.5 kHz.

Applied Sciences•Mar 27, 2019•1 citation

Generation of audio-band frequency squeezed light at 1.34 μm

Feng Jin-Xia, 杜京师 DU Jing-shi, Jin Xiao-Li +2 more

Continuous variable (CV) audio-band frequency squeezed states at the fiber telecommunication wavelength is an important quantum resource for the practical applications based on optical fiber. As is well known, the optical power attenuation and phase diffusion effect of light at 1.3 μm in standard telecommunication fibres are low and small, respectively. The audio-band frequency squeezed light at 1.34 μm can be utilized to realize quantum precision measurement, such as quantum-enhanced sensing in the low-frequency range, laser interferometer for gravitational wave detection. In this paper, CV audio-band frequency vacuum squeezed states at 1.3 μm are experimentally generated by using a type-I degenerate optical parametric oscillator (DOPO) below the threshold. A home-made continuous-wave single-frequency dual-wavelength (671 nm and 1.34 μm) Nd:YVO4/LBO laser is used as a pump source for DOPO based on a type-I quasi-phase-matched periodically poled KTiOPO4 (PPKTP) crystal. Mode cleaners with a finesse of 400 and linewidth of 0.75 MHz are used to filter the noise of lasers at 671 nm and 1.34 μm, respectively. The intensity noises of the two lasers reach a shot noise level for analysis frequencies higher than 1.0 MHz and their phase noises reach shot noise level for analysis frequencies higher than 1.3 MHz, respectively. The low noise single-frequency 671 nm laser is utilized as a pump of the DOPO. The threshold power of the DOPO is 450 mW. In order to detect the audio-band frequency vacuum squeezed states, the power of local oscillator of a homodyne detector system is optimized to 60 μupW. Furthermore, the effect of common mode rejection ratio (CMRR) of detectors is discussed in detecting the audio-band frequency vacuum squeezed states. Improvement of CMRR of detectors is a good way to detect the audio-band frequency vacuum squeezed states effectively. When the phase matching temperature of PPKTP crystal is controlled at 53℃ by using a home-made temperature controller and the pump power is 95 mW, the vacuum squeezed states are generated at analysis frequency ranging from 8-100 kHz. A maximum measured squeeze of 5.0 dB is obtained at analysis frequency of 36 kHz. A 3.0 dB squeezed light is obtained at an audio-band frequency of 8 kHz.

Acta Physica Sinica•Jan 1, 2018•2 citations

Squeezing-enhanced heterodyne detection of 10 Hz atto-Watt optical signals

Boya Xie, Sheng Feng

A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.

Optics Letters•Dec 12, 2018•23 citations
Vacuum fluctuation at audio frequencies is very important and interesting in many research fields, such as the gravitational wave detection, ultra-weak magnetic field measurement, and the research of quantum metrology, etc. Since the generation of squeezed light in 1985, most of the squeezed light have been generated and measured at radio frequencies (~MHz) as there has not been much technical noise at higher frequencies. In the Michelson-interferometer-based gravitational wave detection, the detection band has frequencies from a few to tens of thousands Hz. Measuring vacuum noise at such low frequencies is a challenge since we have to stabilize and control all the audio noises and the interferences from a variety of mechanical and electronic noises, therefore a very high classical noise suppression is needed when the measurement time increases. In order to measure the squeezed light of low frequencies, the standard vacuum noise at audio frequencies must be measured. In this paper, a balanced homodyne detection system for measuring the low-frequency quantum vacuum noises is reported. It is not trivial to extend the detected frequency to very low analysis frequencies. Through a self-made self-subtraction balanced homodyne configuration, which can eliminate the DC component of each photocurrent from the photodiode and the classical common-mode technical noise, the standard vacuum noise has been detected. The linearity of the vacuum noise power has been validated by varying the local oscillator power, showing that the saturation power of light incidence is about 3.2 mW. When the incident-light power is 400 W, the standard vacuum noise is 11 dB higher than the electronic noise at 80 Hz. In the regime of about 80 Hz to 400 kHz, the linearity of the standard noise power as a function of incident laser power is verified. However, when the measurement is carried out at even lower frequencies, for example, 50 Hz, we may encounter some excess and non-stationary noises and find that the measured noise power is not proportional to the incident light power any more. These non-stationary noises are the main technical obstacle at low frequencies. The average common mode rejection ratio in the test frequency range from 10 Hz to 400 kHz is 55 dB and its maximum 63 dB at 100 Hz is obtained, implying a high suppression of the technical noise. This self-made homodyne vacuum noise detector can be widely used for precision measurement in quantum metrology and quantum optics.
The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.
The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.
The research of quantum noise in the interaction of laser and atoms plays a critical role in quantum optical experiments. The measurement of quantum noise is mainly based on the balanced homodyne detection method. Here, we reported a balanced homodyne detector with low noise, high gain, and high common-mode rejection ratio (CMRR) at the wavelength of 795 nm. By optimizing the selection of components and printed circuit board (PCB) layout, a minimum electronic noise of −96.7 dBm is obtained. Over the range of 1 MHz to 5 MHz, we get a flat CMRR above 59 dB and a linear gain regime, which can enable a shot noise measurement with the laser power of100 μw100~\mu \text{w}100 μw. The developed detector can be used in quantum coherent experiments with a weak probe laser of power down to tens of microwatts.
Squeezed vacuum states at audio-band frequencies are important quantum resources for practical applications. We demonstrated the generation of squeezed vacuum states at the audio-band frequencies from a subthreshold optical parametric oscillator with a periodically poled KTiOPO4 crystal pumped by a homemade continuous wave single-frequency dual-wavelength laser. To detect squeezed vacuum states at audio-band frequencies, the influences of the local oscillator (LO) power, the common mode rejection ratio (CMRR) of balanced homodyne detectors, and the phase jitter between the LO and squeezed vacuum field on the measurement of squeezed vacuum states at audio-band frequencies were considered. By optimizing the LO power, improving the CMRR of photodetectors to 67 dB based on the design of differential fine-tuning circuit and adjustable bias voltage, and reducing the phase jitter between the LO and squeezed vacuum field to 1.7° with the help of the coherent locking technique, 6.1 ± 0.3 dB squeezed vacuum states at audio frequencies from 5 kHz to 20 kHz were generated. A 3.0 ± 0.3 dB phase squeezed vacuum state was obtained at the audio frequency of 3.5 kHz.
Continuous variable (CV) audio-band frequency squeezed states at the fiber telecommunication wavelength is an important quantum resource for the practical applications based on optical fiber. As is well known, the optical power attenuation and phase diffusion effect of light at 1.3 μm in standard telecommunication fibres are low and small, respectively. The audio-band frequency squeezed light at 1.34 μm can be utilized to realize quantum precision measurement, such as quantum-enhanced sensing in the low-frequency range, laser interferometer for gravitational wave detection. In this paper, CV audio-band frequency vacuum squeezed states at 1.3 μm are experimentally generated by using a type-I degenerate optical parametric oscillator (DOPO) below the threshold. A home-made continuous-wave single-frequency dual-wavelength (671 nm and 1.34 μm) Nd:YVO4/LBO laser is used as a pump source for DOPO based on a type-I quasi-phase-matched periodically poled KTiOPO4 (PPKTP) crystal. Mode cleaners with a finesse of 400 and linewidth of 0.75 MHz are used to filter the noise of lasers at 671 nm and 1.34 μm, respectively. The intensity noises of the two lasers reach a shot noise level for analysis frequencies higher than 1.0 MHz and their phase noises reach shot noise level for analysis frequencies higher than 1.3 MHz, respectively. The low noise single-frequency 671 nm laser is utilized as a pump of the DOPO. The threshold power of the DOPO is 450 mW. In order to detect the audio-band frequency vacuum squeezed states, the power of local oscillator of a homodyne detector system is optimized to 60 μupW. Furthermore, the effect of common mode rejection ratio (CMRR) of detectors is discussed in detecting the audio-band frequency vacuum squeezed states. Improvement of CMRR of detectors is a good way to detect the audio-band frequency vacuum squeezed states effectively. When the phase matching temperature of PPKTP crystal is controlled at 53℃ by using a home-made temperature controller and the pump power is 95 mW, the vacuum squeezed states are generated at analysis frequency ranging from 8-100 kHz. A maximum measured squeeze of 5.0 dB is obtained at analysis frequency of 36 kHz. A 3.0 dB squeezed light is obtained at an audio-band frequency of 8 kHz.
A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.