Optics Letters

Squeezing-enhanced heterodyne detection of 10 Hz atto-Watt optical signals

Boya Xie, Sheng Feng

Published Dec 12, 2018• 23 citations
Publisher

Abstract

A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.

DOI
10.1364/ol.43.006073

Related papers

Phase-sensitive heterodyne detection of two-mode squeezed light without noise penalty

Boya Xie, Peng Yang, Sheng Feng

Squeezed states of light can be detected for precision measurements with a heterodyne detector by use of a bichromatic field as the local oscillator, due to the phase-sensitive nature of the device. However, divergence consists of the theoretical description of the quantum noise performance of this detector. Two existing theoretical models are briefly reviewed, with one model predicting a 3 dB quantum noise floor change in detection of two-mode squeezed light if the local oscillator is replaced by a monochromatic one, whereas the other model foretells the same noise floor no matter which local oscillator is used. An experiment on heterodyne detection of two-mode squeezed light is carried out to put the two models under test. No significant difference in the noise floor level is observed between the two detectors, showing the noiseless property of both detectors. This work should be of importance for the understanding of noise origin in optical detection and of great interest in practical application for squeezing-enhanced audio band gravitational-wave signal searching.

Journal of the Optical Society of America B•Sep 4, 2018•10 citations

Quantum-enhanced optical phase-insensitive heterodyne detection beyond 3-dB noise penalty of image band

Keitaro Anai, Yutaro Enomoto, H. Omura +4 more

Optical phase-insensitive heterodyne (beat-note) detection, which measures the relative phase of two beams at different frequencies through their interference, is a key sensing technology for various spatial/temporal measurements, such as frequency measurements in optical frequency combs. However, its sensitivity is limited not only by shot noise from the signal frequency band but also by the extra shot noise from an image band, known as the 3-dB noise penalty. Here, we propose a method to remove shot noise from all these bands using squeezed light. We also demonstrate beyond-3-dB noise reduction experimentally, confirming that our method actually reduces shot noise from both the signal and extra bands simultaneously. Our work should boost the sensitivity of various spatial/temporal measurements beyond the current limitations.

arXiv:2305.06579•Optics Express•May 2, 2024•8 citations

Subhertz interferometry at the quantum noise limit

Peng Yang, Boya Xie, Sheng Feng

Quantum noise limited interferometry for subhertz phase measurement is of essence in precision metrology applications, such as gravitational wave detection. However, suppression of subhertz classical noises below the shot-noise level is very challenging in practice. Two-frequency interferometry has been previously proposed to avoid low-frequency noises and may be useful for squeezing-enhanced high-precision phase measurement. Here we experimentally demonstrate a subhertz interferometer at the standard quantum noise (shot-noise) limit, by use of dual-frequency coherent probe light at the input and phase-sensitive heterodyne detection to measure the output interfered light. When the interferometer is locked at a dark fringe, the noise floor of the phase variance in the interferometer reaches the shot-noise level down to Fourier frequencies below 1 Hz. This work should pave a way for a realization of subhertz interferometry beyond the shot-noise limit.

Optics Letters•Apr 29, 2019•12 citations

Balanced-heterodyne detection of sub-shot-noise optical signals

Sheng Feng, Lu, Zehuan, Jie Zhang +1 more

As part of the effort to make use of squeezed states of light for detection of sub-shot-noise optical signals, we study the balanced heterodyne scheme, for which the corresponding spectral density of the photocurrent fluctuations produced at the output of the detector is calculated as the Fourier transform of their autocorrelation function. Our analysis shows that, for maximal signal-to-noise ratio enhancement by use of squeezed states of light, an optical signal to be measured must be carried in the squeezed quadrature of the carrier field. We discuss how "the additional heterodyne noise" can be eliminated in this scheme and its potential application to gravitational-wave searching. To demonstrate the practical feasibility, we propose and study a phase-locking technique for this scheme.

arXiv:1112.3155•Dec 14, 2011•1 citation

Quantum noise reduction using squeezed states inLIGO; Sensitivity improvement of a LIGO gravitational Waynedetector through squeezed state injection

S. E. Dwyer

Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.

•Jan 1, 2013•0 citations

Balanced homodyne detection of optical quantum states at audio-band frequencies and below

M S Stefszky, C M Mow-Lowry, S. Chua +7 more

The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.

arXiv:1205.3229•Classical and Quantum Gravity•Jun 25, 2012•127 citations
A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.
Squeezed states of light can be detected for precision measurements with a heterodyne detector by use of a bichromatic field as the local oscillator, due to the phase-sensitive nature of the device. However, divergence consists of the theoretical description of the quantum noise performance of this detector. Two existing theoretical models are briefly reviewed, with one model predicting a 3 dB quantum noise floor change in detection of two-mode squeezed light if the local oscillator is replaced by a monochromatic one, whereas the other model foretells the same noise floor no matter which local oscillator is used. An experiment on heterodyne detection of two-mode squeezed light is carried out to put the two models under test. No significant difference in the noise floor level is observed between the two detectors, showing the noiseless property of both detectors. This work should be of importance for the understanding of noise origin in optical detection and of great interest in practical application for squeezing-enhanced audio band gravitational-wave signal searching.
Optical phase-insensitive heterodyne (beat-note) detection, which measures the relative phase of two beams at different frequencies through their interference, is a key sensing technology for various spatial/temporal measurements, such as frequency measurements in optical frequency combs. However, its sensitivity is limited not only by shot noise from the signal frequency band but also by the extra shot noise from an image band, known as the 3-dB noise penalty. Here, we propose a method to remove shot noise from all these bands using squeezed light. We also demonstrate beyond-3-dB noise reduction experimentally, confirming that our method actually reduces shot noise from both the signal and extra bands simultaneously. Our work should boost the sensitivity of various spatial/temporal measurements beyond the current limitations.
Quantum noise limited interferometry for subhertz phase measurement is of essence in precision metrology applications, such as gravitational wave detection. However, suppression of subhertz classical noises below the shot-noise level is very challenging in practice. Two-frequency interferometry has been previously proposed to avoid low-frequency noises and may be useful for squeezing-enhanced high-precision phase measurement. Here we experimentally demonstrate a subhertz interferometer at the standard quantum noise (shot-noise) limit, by use of dual-frequency coherent probe light at the input and phase-sensitive heterodyne detection to measure the output interfered light. When the interferometer is locked at a dark fringe, the noise floor of the phase variance in the interferometer reaches the shot-noise level down to Fourier frequencies below 1 Hz. This work should pave a way for a realization of subhertz interferometry beyond the shot-noise limit.
As part of the effort to make use of squeezed states of light for detection of sub-shot-noise optical signals, we study the balanced heterodyne scheme, for which the corresponding spectral density of the photocurrent fluctuations produced at the output of the detector is calculated as the Fourier transform of their autocorrelation function. Our analysis shows that, for maximal signal-to-noise ratio enhancement by use of squeezed states of light, an optical signal to be measured must be carried in the squeezed quadrature of the carrier field. We discuss how "the additional heterodyne noise" can be eliminated in this scheme and its potential application to gravitational-wave searching. To demonstrate the practical feasibility, we propose and study a phase-locking technique for this scheme.
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.
The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.