AIP Advances

A battery-powered floating current source of 100 A for precise and fast control of magnetic field

Yu-Meng Yang, Bo Xiao, Wen-Chao Ji, Xuan-Kai Wang, Han-Ning Dai, Yu-Ao Chen, Zhen-Sheng Yuan, Xiao Qiang Jiang

Published Dec 1, 2020• 3 citations
Publisher

Abstract

In various leading-edge ultracold atom experiments in fields such as quantum simulation, quantum computing, and quantum precision measurement, precise and fast control of the magnetic field is important and a current source with a low noise level and high control bandwidth is required. Conventional commercial current sources, even the expensive ones, may not meet the requirements. Here, we present a battery-powered current source (BPCS) solution that has a maximum output of 100 A with a root-mean-square noise of about only 0.35 mA (integrated from 1 Hz to 3 MHz) and a control bandwidth of about 10 kHz. The large output current is sourced from a lead-acid battery, a fluxgate current sensor is used to detect the output current, and fast feedback regulation is done by using an insulated-gate bipolar transistor under the control of an analog proportional-integral controller. The battery power method eliminates the switching noise. A prepulse method is applied to shorten the settling time when the current steps down from a high level to a low level that is close to zero. These features make the BPCS a suitable analog-controlled floating current source for cold-atom experiments such as the preparation of a single 2D quantum gas and optical lattice atomic clocks.

DOI
10.1063/5.0006490

Related papers

Ultra-low noise bipolar current source for ultracold atom magnetic system

Haotian Liu, Shuai Peng, Bolong Jiao +2 more

We report the development of an ultralow-noise bipolar current source based on the configuration of H-bridge current switching. The measured relative current noise fluctuation reaches 4 × 10-9 Hz-1/2, which enables an ultra-stable magnetic system for cold atom experiments. We avoid the influence of the AC leakage currents induced by the large parasitic capacitance of the H-bridge. First, the current sensor is placed as close as possible to the magnetic coils so that the systematic errors from these leakage currents are minimized. Second, the large parasitic capacitance, which parallels the magnetic coils and forms an LC oscillator, is removed from the feedback loop in our setup to maintain a large self-resonance frequency of the feedback control loop. These two improvements lead to a current source that is more precise and less noisy. Remarkably, the lowest current noise density produced by the proposed method is only 500 nA Hz-1/2 at a current of 100 A, which is about ten fold smaller than the case with leakage current. To optimize the feedback control, a numerical simulation is implemented by using Matlab Simulink, and the numerical simulation results are entirely consistent with the experimental results.

Review of Scientific Instruments•May 1, 2023•10 citations

Simple and active magnetic-field stabilization for cold atom experiments

Zhi-Xin Duan, Wei-Tao Wu, Yuetong Lin +1 more

Cold atom experiments usually need a controllable and low-noise bias magnetic field to provide a quantization axis. Most labs need home-made stabilization of the field according to the actual setup, as commercially available power supply cannot directly satisfy their requirements. Here, by measuring the field fluctuations and active feedback modulating current supply of the applied magnetic field, we successfully demonstrate a field of 10.58 G with a stability to the level of 2.8 × 10−7 in a duration of 5 min. The root mean square noise is reduced to 0.05 mG, compared to the noise of 1.3 mG without stabilization. The coherence time of the magnetic-field sensitive transition between the rubidium ground states F=1,mF=−1 and 1,0, as measured by Rabi oscillation, is extended to 19.2 ms from the unstabilized value of 1.3 ms. This result is long enough for most experiments on quantum simulation and precision measurement. As our system has no passive magnetic shielding and additional compensation coils, it is highly simple and compact to provide the stable magnetic field and would be adapted to various applications with cold atoms.

Review of Scientific Instruments•Dec 1, 2022•12 citations

Active stabilization of kilogauss magnetic fields to the ppm level for magnetoassociation on ultranarrow Feshbach resonances

Mateusz Borkowski, Lukas Reichsöllner, Premjith Thekkeppatt +4 more

Feshbach association of ultracold molecules using narrow resonances requires exquisite control of the applied magnetic field. Here, we present a magnetic field control system to deliver magnetic fields of over 1000 G with ppm-level precision integrated into an ultracold-atom experimental setup. We combine a battery-powered, current-stabilized power supply with active feedback stabilization of the magnetic field using fluxgate magnetic field sensors. As a real-world test, we perform microwave spectroscopy of ultracold Rb atoms and demonstrate an upper limit on our magnetic field stability of 2.4(3) mG at 1050 G [2.3(3) ppm relative] as determined from the spectral feature.

arXiv:2303.13682•Review of Scientific Instruments•Jul 1, 2023•19 citations

Direct control of high magnetic fields for cold atom experiments based on NV centers

Alexander Hesse, Kerim Köster, Jakob M. Steiner +5 more

Abstract In ultracold quantum gases, the interactions between the individual atoms can be controlled by applying magnetic bias fields. As magnetic field fluctuations limit the precision here, typically a feedback loop needs to be employed to regulate the current through a pair of Helmholtz coils. No commercially available magnetic field sensor allows to measure large fields directly with high enough precision, leading to many unsatisfactory solutions being used in experiments. Here, we demonstrate a direct magnetic field stabilization in a regime previously not accessible, using NV centers as the magnetic field sensor. This allows us to measure and stabilize fields of 4.66 mT down to 12 nT RMS noise over the course of 24 h, measured on a 1 Hz bandwidth. We achieve a control of better than 1 ppm after 20 min of integration time, ensuring high long-term stability for experiments. This approach extends direct magnetic field control to strong magnetic fields, which could enable new precise quantum simulations in this regime.

arXiv:2003.08101•New Journal of Physics•Feb 1, 2021•8 citations

Fast magnetic coil controller for cold atom experiments

Leonardo Uhthoff-Rodríguez, A. Hernández-López, Edgar Giovanni Alonso-Torres +5 more

Cold atom experiments utilize magnetic fields, commonly generated by coils, as an essential tool to control and manipulate atomic samples. In these experiments, it is often necessary to rapidly switch the magnetic field between two values. However, typical power supplies have a limited switching time for the current flowing through the coil. We present a control scheme implemented as an electronic circuit that overcomes this limitation. A faster control is achieved by momentarily applying an on-demand high voltage when the control signal variation surpasses the limits that the conventional power supply can follow, allowing a faster current flow into the magnetic coil. In our specific application, a coil with an inductance of 491 μH and a resistance of 0.26 Ω, corresponding to a time constant of ∼1.9 ms, is driven so that its current faithfully follows the control signals from -1 to 1 A. It is capable of completing a full-scale transition in just ∼31 μs, with an effective bandwidth of 15.2 kHz. This corresponds to an improvement by a factor of more than 20 in both bandwidth and switching speed over a conventional power supply. By appropriately selecting the components of the circuit, both the bandwidth and switching time can be tuned to match specific needs within a wide range of inductive and power requirements.

arXiv:2503.22554•Review of Scientific Instruments•Oct 1, 2025•1 citation

A digital feedback controller for stabilizing large electric currents to the ppm level for Feshbach resonance studies

Ryan Thomas, Niels Kjærgaard

Magnetic Feshbach resonances are a key tool in the field of ultracold quantum gases, but their full exploitation requires the generation of large, stable magnetic fields up to 1000 G with fractional stabilities of better than 10−4. Design considerations for electromagnets producing these fields, such as optical access and fast dynamical response, mean that electric currents in excess of 100 A are often needed to obtain the requisite field strengths. We describe a simple digital proportional-integral-derivative current controller constructed using a field-programmable gate array and off-the-shelf evaluation boards that allows for gain scheduling, enabling optimal control of current sources with non-linear actuators. Our controller can stabilize an electric current of 337.5 A to the level of 7.5 × 10−7 in an averaging time of 10 min and with a control bandwidth of 2 kHz.

arXiv:1909.11257•Review of Scientific Instruments•Mar 1, 2020•16 citations
In various leading-edge ultracold atom experiments in fields such as quantum simulation, quantum computing, and quantum precision measurement, precise and fast control of the magnetic field is important and a current source with a low noise level and high control bandwidth is required. Conventional commercial current sources, even the expensive ones, may not meet the requirements. Here, we present a battery-powered current source (BPCS) solution that has a maximum output of 100 A with a root-mean-square noise of about only 0.35 mA (integrated from 1 Hz to 3 MHz) and a control bandwidth of about 10 kHz. The large output current is sourced from a lead-acid battery, a fluxgate current sensor is used to detect the output current, and fast feedback regulation is done by using an insulated-gate bipolar transistor under the control of an analog proportional-integral controller. The battery power method eliminates the switching noise. A prepulse method is applied to shorten the settling time when the current steps down from a high level to a low level that is close to zero. These features make the BPCS a suitable analog-controlled floating current source for cold-atom experiments such as the preparation of a single 2D quantum gas and optical lattice atomic clocks.
We report the development of an ultralow-noise bipolar current source based on the configuration of H-bridge current switching. The measured relative current noise fluctuation reaches 4 × 10-9 Hz-1/2, which enables an ultra-stable magnetic system for cold atom experiments. We avoid the influence of the AC leakage currents induced by the large parasitic capacitance of the H-bridge. First, the current sensor is placed as close as possible to the magnetic coils so that the systematic errors from these leakage currents are minimized. Second, the large parasitic capacitance, which parallels the magnetic coils and forms an LC oscillator, is removed from the feedback loop in our setup to maintain a large self-resonance frequency of the feedback control loop. These two improvements lead to a current source that is more precise and less noisy. Remarkably, the lowest current noise density produced by the proposed method is only 500 nA Hz-1/2 at a current of 100 A, which is about ten fold smaller than the case with leakage current. To optimize the feedback control, a numerical simulation is implemented by using Matlab Simulink, and the numerical simulation results are entirely consistent with the experimental results.
Cold atom experiments usually need a controllable and low-noise bias magnetic field to provide a quantization axis. Most labs need home-made stabilization of the field according to the actual setup, as commercially available power supply cannot directly satisfy their requirements. Here, by measuring the field fluctuations and active feedback modulating current supply of the applied magnetic field, we successfully demonstrate a field of 10.58 G with a stability to the level of 2.8 × 10−7 in a duration of 5 min. The root mean square noise is reduced to 0.05 mG, compared to the noise of 1.3 mG without stabilization. The coherence time of the magnetic-field sensitive transition between the rubidium ground states F=1,mF=−1 and 1,0, as measured by Rabi oscillation, is extended to 19.2 ms from the unstabilized value of 1.3 ms. This result is long enough for most experiments on quantum simulation and precision measurement. As our system has no passive magnetic shielding and additional compensation coils, it is highly simple and compact to provide the stable magnetic field and would be adapted to various applications with cold atoms.
Feshbach association of ultracold molecules using narrow resonances requires exquisite control of the applied magnetic field. Here, we present a magnetic field control system to deliver magnetic fields of over 1000 G with ppm-level precision integrated into an ultracold-atom experimental setup. We combine a battery-powered, current-stabilized power supply with active feedback stabilization of the magnetic field using fluxgate magnetic field sensors. As a real-world test, we perform microwave spectroscopy of ultracold Rb atoms and demonstrate an upper limit on our magnetic field stability of 2.4(3) mG at 1050 G [2.3(3) ppm relative] as determined from the spectral feature.
Abstract In ultracold quantum gases, the interactions between the individual atoms can be controlled by applying magnetic bias fields. As magnetic field fluctuations limit the precision here, typically a feedback loop needs to be employed to regulate the current through a pair of Helmholtz coils. No commercially available magnetic field sensor allows to measure large fields directly with high enough precision, leading to many unsatisfactory solutions being used in experiments. Here, we demonstrate a direct magnetic field stabilization in a regime previously not accessible, using NV centers as the magnetic field sensor. This allows us to measure and stabilize fields of 4.66 mT down to 12 nT RMS noise over the course of 24 h, measured on a 1 Hz bandwidth. We achieve a control of better than 1 ppm after 20 min of integration time, ensuring high long-term stability for experiments. This approach extends direct magnetic field control to strong magnetic fields, which could enable new precise quantum simulations in this regime.
Cold atom experiments utilize magnetic fields, commonly generated by coils, as an essential tool to control and manipulate atomic samples. In these experiments, it is often necessary to rapidly switch the magnetic field between two values. However, typical power supplies have a limited switching time for the current flowing through the coil. We present a control scheme implemented as an electronic circuit that overcomes this limitation. A faster control is achieved by momentarily applying an on-demand high voltage when the control signal variation surpasses the limits that the conventional power supply can follow, allowing a faster current flow into the magnetic coil. In our specific application, a coil with an inductance of 491 μH and a resistance of 0.26 Ω, corresponding to a time constant of ∼1.9 ms, is driven so that its current faithfully follows the control signals from -1 to 1 A. It is capable of completing a full-scale transition in just ∼31 μs, with an effective bandwidth of 15.2 kHz. This corresponds to an improvement by a factor of more than 20 in both bandwidth and switching speed over a conventional power supply. By appropriately selecting the components of the circuit, both the bandwidth and switching time can be tuned to match specific needs within a wide range of inductive and power requirements.
Magnetic Feshbach resonances are a key tool in the field of ultracold quantum gases, but their full exploitation requires the generation of large, stable magnetic fields up to 1000 G with fractional stabilities of better than 10−4. Design considerations for electromagnets producing these fields, such as optical access and fast dynamical response, mean that electric currents in excess of 100 A are often needed to obtain the requisite field strengths. We describe a simple digital proportional-integral-derivative current controller constructed using a field-programmable gate array and off-the-shelf evaluation boards that allows for gain scheduling, enabling optimal control of current sources with non-linear actuators. Our controller can stabilize an electric current of 337.5 A to the level of 7.5 × 10−7 in an averaging time of 10 min and with a control bandwidth of 2 kHz.