Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2503.22554 · Review of Scientific Instruments

Fast magnetic coil controller for cold atom experiments

Leonardo Uhthoff-Rodríguez, A. Hernández-López, Edgar Giovanni Alonso-Torres, Eduardo Esquivel-Ramírez, G. Carmona-Torres, Carlos Gardea-Flores, Jorge Amin Seman, Asaf Paris-Mandoki

Published Oct 1, 2025• 1 citation
arXivHTMLPDF

Abstract

Cold atom experiments utilize magnetic fields, commonly generated by coils, as an essential tool to control and manipulate atomic samples. In these experiments, it is often necessary to rapidly switch the magnetic field between two values. However, typical power supplies have a limited switching time for the current flowing through the coil. We present a control scheme implemented as an electronic circuit that overcomes this limitation. A faster control is achieved by momentarily applying an on-demand high voltage when the control signal variation surpasses the limits that the conventional power supply can follow, allowing a faster current flow into the magnetic coil. In our specific application, a coil with an inductance of 491 μH and a resistance of 0.26 Ω, corresponding to a time constant of ∼1.9 ms, is driven so that its current faithfully follows the control signals from -1 to 1 A. It is capable of completing a full-scale transition in just ∼31 μs, with an effective bandwidth of 15.2 kHz. This corresponds to an improvement by a factor of more than 20 in both bandwidth and switching speed over a conventional power supply. By appropriately selecting the components of the circuit, both the bandwidth and switching time can be tuned to match specific needs within a wide range of inductive and power requirements.

DOI
10.1063/5.0271452

Related papers

A low-impedance radio-frequency circuit for fast spin manipulations in cold alkali atoms

Francesco Scazza, Giulia Del Pace, L. Pieri +3 more

We design and implement a low-impedance, high-current radio-frequency (RF) circuit, enabling fast coherent coupling between magnetic levels in cold alkali atomic samples. It is based on a compact, shape-optimized coil that maximizes the RF field coupling with the atomic magnetic dipole, and on coaxial transmission-line transformers that step up the field-generating current flowing in the coil by a factor ∼4 to about 7.5 A for 100 W of RF driving. This allows us to obtain a RF coupling field of about 0.035G/W at the atomic sample location. The system is robust and versatile, as it generates a large RF field without compromising the available optical access, and its central resonant frequency can be adjusted in situ. Our approach provides a cost-effective, reliable solution, featuring a negligible level of interference with surrounding electronic equipment thanks to its symmetric layout. We test the circuit performance using a maximum RF power of 80 W at a frequency around 82 MHz, which corresponds to a measured Rabi frequency ΩR/2π ≃ 18.5 kHz, that is, a π-pulse duration of about 27 μs, between two of the lowest states of 6Li at an offset magnetic field of 770 G. Our solution can be readily adapted to other atomic species and vacuum chamber designs, in view of an increasing modularity of cold atom experiments.

arXiv:2104.12730•Review of Scientific Instruments•Oct 1, 2025•2 citations

Simple and active magnetic-field stabilization for cold atom experiments

Zhi-Xin Duan, Wei-Tao Wu, Yuetong Lin +1 more

Cold atom experiments usually need a controllable and low-noise bias magnetic field to provide a quantization axis. Most labs need home-made stabilization of the field according to the actual setup, as commercially available power supply cannot directly satisfy their requirements. Here, by measuring the field fluctuations and active feedback modulating current supply of the applied magnetic field, we successfully demonstrate a field of 10.58 G with a stability to the level of 2.8 × 10−7 in a duration of 5 min. The root mean square noise is reduced to 0.05 mG, compared to the noise of 1.3 mG without stabilization. The coherence time of the magnetic-field sensitive transition between the rubidium ground states F=1,mF=−1 and 1,0, as measured by Rabi oscillation, is extended to 19.2 ms from the unstabilized value of 1.3 ms. This result is long enough for most experiments on quantum simulation and precision measurement. As our system has no passive magnetic shielding and additional compensation coils, it is highly simple and compact to provide the stable magnetic field and would be adapted to various applications with cold atoms.

Review of Scientific Instruments•Dec 1, 2022•12 citations

A compact and fast magnetic coil for the manipulation of quantum gases with Feshbach resonances

A. Kell, M. Link, Moritz Breyer +3 more

Cold atom experiments commonly use broad magnetic Feshbach resonances to manipulate the interaction between atoms. In order to induce quantum dynamics by a change in the interaction strength, rapid (∼μs) magnetic field changes over several tens of Gauss are required. Here, we present a compact design of a coil and its control circuit for a change in the magnetic field up to 36 G in 3 µs. The setup comprises two concentric solenoids with minimal space requirements, which can be readily added to existing apparatuses. This design makes the observation of non-equilibrium physics with broad Feshbach resonances accessible.

arXiv:2103.05273•Review of Scientific Instruments•Sep 1, 2021•11 citations

Efficient water-cooled Bitter-type electromagnet for Zeeman slowing in cold-atom experiments

Rishav Koirala, Ben A. Olsen

We describe the design, construction, and characterization of a Bitter-type electromagnet that produces a spatially-dependent magnetic field used for Zeeman slowing in cold-atom experiments. The coil consists of stacked copper arcs separated by PTFE spacers of varying thicknesses, generating a near-optimal field profile using a single power supply. With an electrical resistance of 26.5(3) mΩ and self-inductance of 19.1(1) μH, our design achieves a fast electrical switching time of τ ≈ 100 μs in a compact, 30-cm-long package. Water circulating helically through holes in the copper and channels in the spacers ensures efficient thermal management, limiting the temperature rise to ∼5° C over 36 s of continuous operation at 200 A.

arXiv:2510.21064•Review of Scientific Instruments•Mar 1, 2026•0 citations

A radio frequency emitter design for the low-frequency regime in atomic experiments

Yicheng Wei, Zhongshu Hu, Yajing Guo +4 more

Radio frequency (RF) control is a key technique in cold atom experiments. We present a compact and efficient RF circuit based on a capacitive transformer network, where a low-frequency coil operating up to 30 MHz serves as both an intrinsic inductor and a power-sharing element. The design enables high current delivery and flexible impedance matching across a wide frequency range. We integrate both broadband and narrowband RF networks into a unified configuration that overcomes the geometric constraints imposed by the metallic chamber. In evaporative cooling, the broadband network allows a reduction in the applied RF input power from 14.7 dBW to -3.5 dBW, owing to its non-zero coil current even at ultra-low frequencies. This feature enables the Bose-Fermi mixture to be cooled below 10 μK. In a Landau-Zener protocol, the coil driven by the narrowband network transfers 80% of rubidium atoms from |F = 2, mF = 2⟩ to |2, -2⟩ in 1 millisecond, achieving a Rabi frequency of ∼9 kHz at an input power of 0.1 dBW.

arXiv:2502.11549•Review of Scientific Instruments•Sep 1, 2025•1 citation

A fast-switching high-critical-temperature superconducting magnetic trap for atoms and molecules

Julia Narevicius, Yair Segev, Martin Pitzer +1 more

We present a 1 T deep high-critical-temperature (high-Tc) superconducting magnetic trap with magnetic field transients reaching 2000 T/s, spatial gradients of ∼0.3 T/mm, and arbitrarily tunable time evolution of the trapping field intensity for durations up to several minutes. In addition, our trap driver electronic circuit allows independent operation of the two superconducting coils with only a single high-current power supply and two cryogenic leads. By implementing the possibility to change polarity of the current pulse in one of the trap coils, we enable a compact design that facilitates the loading sequence of a high-gradient magnetic quadrupole trap.

Review of Scientific Instruments•Mar 1, 2026•0 citations
Cold atom experiments utilize magnetic fields, commonly generated by coils, as an essential tool to control and manipulate atomic samples. In these experiments, it is often necessary to rapidly switch the magnetic field between two values. However, typical power supplies have a limited switching time for the current flowing through the coil. We present a control scheme implemented as an electronic circuit that overcomes this limitation. A faster control is achieved by momentarily applying an on-demand high voltage when the control signal variation surpasses the limits that the conventional power supply can follow, allowing a faster current flow into the magnetic coil. In our specific application, a coil with an inductance of 491 μH and a resistance of 0.26 Ω, corresponding to a time constant of ∼1.9 ms, is driven so that its current faithfully follows the control signals from -1 to 1 A. It is capable of completing a full-scale transition in just ∼31 μs, with an effective bandwidth of 15.2 kHz. This corresponds to an improvement by a factor of more than 20 in both bandwidth and switching speed over a conventional power supply. By appropriately selecting the components of the circuit, both the bandwidth and switching time can be tuned to match specific needs within a wide range of inductive and power requirements.
We design and implement a low-impedance, high-current radio-frequency (RF) circuit, enabling fast coherent coupling between magnetic levels in cold alkali atomic samples. It is based on a compact, shape-optimized coil that maximizes the RF field coupling with the atomic magnetic dipole, and on coaxial transmission-line transformers that step up the field-generating current flowing in the coil by a factor ∼4 to about 7.5 A for 100 W of RF driving. This allows us to obtain a RF coupling field of about 0.035G/W at the atomic sample location. The system is robust and versatile, as it generates a large RF field without compromising the available optical access, and its central resonant frequency can be adjusted in situ. Our approach provides a cost-effective, reliable solution, featuring a negligible level of interference with surrounding electronic equipment thanks to its symmetric layout. We test the circuit performance using a maximum RF power of 80 W at a frequency around 82 MHz, which corresponds to a measured Rabi frequency ΩR/2π ≃ 18.5 kHz, that is, a π-pulse duration of about 27 μs, between two of the lowest states of 6Li at an offset magnetic field of 770 G. Our solution can be readily adapted to other atomic species and vacuum chamber designs, in view of an increasing modularity of cold atom experiments.
Cold atom experiments usually need a controllable and low-noise bias magnetic field to provide a quantization axis. Most labs need home-made stabilization of the field according to the actual setup, as commercially available power supply cannot directly satisfy their requirements. Here, by measuring the field fluctuations and active feedback modulating current supply of the applied magnetic field, we successfully demonstrate a field of 10.58 G with a stability to the level of 2.8 × 10−7 in a duration of 5 min. The root mean square noise is reduced to 0.05 mG, compared to the noise of 1.3 mG without stabilization. The coherence time of the magnetic-field sensitive transition between the rubidium ground states F=1,mF=−1 and 1,0, as measured by Rabi oscillation, is extended to 19.2 ms from the unstabilized value of 1.3 ms. This result is long enough for most experiments on quantum simulation and precision measurement. As our system has no passive magnetic shielding and additional compensation coils, it is highly simple and compact to provide the stable magnetic field and would be adapted to various applications with cold atoms.
Cold atom experiments commonly use broad magnetic Feshbach resonances to manipulate the interaction between atoms. In order to induce quantum dynamics by a change in the interaction strength, rapid (∼μs) magnetic field changes over several tens of Gauss are required. Here, we present a compact design of a coil and its control circuit for a change in the magnetic field up to 36 G in 3 µs. The setup comprises two concentric solenoids with minimal space requirements, which can be readily added to existing apparatuses. This design makes the observation of non-equilibrium physics with broad Feshbach resonances accessible.
We describe the design, construction, and characterization of a Bitter-type electromagnet that produces a spatially-dependent magnetic field used for Zeeman slowing in cold-atom experiments. The coil consists of stacked copper arcs separated by PTFE spacers of varying thicknesses, generating a near-optimal field profile using a single power supply. With an electrical resistance of 26.5(3) mΩ and self-inductance of 19.1(1) μH, our design achieves a fast electrical switching time of τ ≈ 100 μs in a compact, 30-cm-long package. Water circulating helically through holes in the copper and channels in the spacers ensures efficient thermal management, limiting the temperature rise to ∼5° C over 36 s of continuous operation at 200 A.
Radio frequency (RF) control is a key technique in cold atom experiments. We present a compact and efficient RF circuit based on a capacitive transformer network, where a low-frequency coil operating up to 30 MHz serves as both an intrinsic inductor and a power-sharing element. The design enables high current delivery and flexible impedance matching across a wide frequency range. We integrate both broadband and narrowband RF networks into a unified configuration that overcomes the geometric constraints imposed by the metallic chamber. In evaporative cooling, the broadband network allows a reduction in the applied RF input power from 14.7 dBW to -3.5 dBW, owing to its non-zero coil current even at ultra-low frequencies. This feature enables the Bose-Fermi mixture to be cooled below 10 μK. In a Landau-Zener protocol, the coil driven by the narrowband network transfers 80% of rubidium atoms from |F = 2, mF = 2⟩ to |2, -2⟩ in 1 millisecond, achieving a Rabi frequency of ∼9 kHz at an input power of 0.1 dBW.
We present a 1 T deep high-critical-temperature (high-Tc) superconducting magnetic trap with magnetic field transients reaching 2000 T/s, spatial gradients of ∼0.3 T/mm, and arbitrarily tunable time evolution of the trapping field intensity for durations up to several minutes. In addition, our trap driver electronic circuit allows independent operation of the two superconducting coils with only a single high-current power supply and two cryogenic leads. By implementing the possibility to change polarity of the current pulse in one of the trap coils, we enable a compact design that facilitates the loading sequence of a high-gradient magnetic quadrupole trap.