Review of Scientific Instruments

Ultra-low noise bipolar current source for ultracold atom magnetic system

Haotian Liu, Shuai Peng, Bolong Jiao, Jiaming Li, Le Luo

Published May 1, 2023• 10 citations
Publisher

Abstract

We report the development of an ultralow-noise bipolar current source based on the configuration of H-bridge current switching. The measured relative current noise fluctuation reaches 4 × 10-9 Hz-1/2, which enables an ultra-stable magnetic system for cold atom experiments. We avoid the influence of the AC leakage currents induced by the large parasitic capacitance of the H-bridge. First, the current sensor is placed as close as possible to the magnetic coils so that the systematic errors from these leakage currents are minimized. Second, the large parasitic capacitance, which parallels the magnetic coils and forms an LC oscillator, is removed from the feedback loop in our setup to maintain a large self-resonance frequency of the feedback control loop. These two improvements lead to a current source that is more precise and less noisy. Remarkably, the lowest current noise density produced by the proposed method is only 500 nA Hz-1/2 at a current of 100 A, which is about ten fold smaller than the case with leakage current. To optimize the feedback control, a numerical simulation is implemented by using Matlab Simulink, and the numerical simulation results are entirely consistent with the experimental results.

DOI
10.1063/5.0142948

Related papers

A battery-powered floating current source of 100 A for precise and fast control of magnetic field

Yu-Meng Yang, Bo Xiao, Wen-Chao Ji +5 more

In various leading-edge ultracold atom experiments in fields such as quantum simulation, quantum computing, and quantum precision measurement, precise and fast control of the magnetic field is important and a current source with a low noise level and high control bandwidth is required. Conventional commercial current sources, even the expensive ones, may not meet the requirements. Here, we present a battery-powered current source (BPCS) solution that has a maximum output of 100 A with a root-mean-square noise of about only 0.35 mA (integrated from 1 Hz to 3 MHz) and a control bandwidth of about 10 kHz. The large output current is sourced from a lead-acid battery, a fluxgate current sensor is used to detect the output current, and fast feedback regulation is done by using an insulated-gate bipolar transistor under the control of an analog proportional-integral controller. The battery power method eliminates the switching noise. A prepulse method is applied to shorten the settling time when the current steps down from a high level to a low level that is close to zero. These features make the BPCS a suitable analog-controlled floating current source for cold-atom experiments such as the preparation of a single 2D quantum gas and optical lattice atomic clocks.

AIP Advances•Dec 1, 2020•3 citations

Direct control of high magnetic fields for cold atom experiments based on NV centers

Alexander Hesse, Kerim Köster, Jakob M. Steiner +5 more

Abstract In ultracold quantum gases, the interactions between the individual atoms can be controlled by applying magnetic bias fields. As magnetic field fluctuations limit the precision here, typically a feedback loop needs to be employed to regulate the current through a pair of Helmholtz coils. No commercially available magnetic field sensor allows to measure large fields directly with high enough precision, leading to many unsatisfactory solutions being used in experiments. Here, we demonstrate a direct magnetic field stabilization in a regime previously not accessible, using NV centers as the magnetic field sensor. This allows us to measure and stabilize fields of 4.66 mT down to 12 nT RMS noise over the course of 24 h, measured on a 1 Hz bandwidth. We achieve a control of better than 1 ppm after 20 min of integration time, ensuring high long-term stability for experiments. This approach extends direct magnetic field control to strong magnetic fields, which could enable new precise quantum simulations in this regime.

arXiv:2003.08101•New Journal of Physics•Feb 1, 2021•8 citations

Simple and active magnetic-field stabilization for cold atom experiments

Zhi-Xin Duan, Wei-Tao Wu, Yuetong Lin +1 more

Cold atom experiments usually need a controllable and low-noise bias magnetic field to provide a quantization axis. Most labs need home-made stabilization of the field according to the actual setup, as commercially available power supply cannot directly satisfy their requirements. Here, by measuring the field fluctuations and active feedback modulating current supply of the applied magnetic field, we successfully demonstrate a field of 10.58 G with a stability to the level of 2.8 × 10−7 in a duration of 5 min. The root mean square noise is reduced to 0.05 mG, compared to the noise of 1.3 mG without stabilization. The coherence time of the magnetic-field sensitive transition between the rubidium ground states F=1,mF=−1 and 1,0, as measured by Rabi oscillation, is extended to 19.2 ms from the unstabilized value of 1.3 ms. This result is long enough for most experiments on quantum simulation and precision measurement. As our system has no passive magnetic shielding and additional compensation coils, it is highly simple and compact to provide the stable magnetic field and would be adapted to various applications with cold atoms.

Review of Scientific Instruments•Dec 1, 2022•12 citations

A configurable ultra-low noise current source for transition-edge sensor characterization

N. Li, G. Liao, Zhengwei Li +12 more

Abstract Transition-edge sensors (TESs) are sensitive devices for detecting photons from millimeter radiation to γ rays. Their photon counting efficiency and collecting area benefit from large-array multiplexing scheme, and therefore the development of multiplexing readout system has been an important topic in this field. Among the many multiplex techniques, time-division multiplexing (TDM) superconducting quantum interference device (SQUID) has been used most widely for TES readout. In this work, we design a Configurable Ultra-Low Noise Current Source (CLCS) for TES characterization and as a part of a whole TDM-TES bias control system. The CLCS is based on the feedback structure of ultra-low noise instrumentation amplifiers and low-noise, high-resolution (20 bits) digital-to-analog converter (DAC). CLCS has an ultra-high resolution of 10 nA in the 0 to 5 mA current output range, and can perform current-voltage (IV) sweep and bias-step tests to measure key TES parameters on board. The feedback structure of the CLCS also avoids the issue of impedance mismatch.

arXiv:2312.12851•Journal of Instrumentation•May 1, 2024•0 citations

Ultra-low noise magnetic field for quantum gases

Xiao-Tian Xu, Zong-Yao Wang, Rui-Heng Jiao +3 more

A ultralow noise magnetic field is essential for many branches of scientific research. Examples include experiments conducted on ultracold atoms, quantum simulations, and precision measurements. In ultracold atom experiments specifically, a bias magnetic field will often serve as a quantization axis and be applied for Zeeman splitting. As atomic states are usually sensitive to magnetic fields, a magnetic field characterized by ultralow noise as well as high stability is typically required for experimentation. For this study, a bias magnetic field is successfully stabilized at 14.5 G, with the root mean square value of the noise reduced to 18.5 μG (1.28 ppm) by placing μ-metal magnetic shields together with a dynamical feedback circuit. Long-time instability is also regulated consistently below 7 μG. The level of noise exhibited in the bias magnetic field is further confirmed by evaluating the coherence time of a Bose-Einstein condensate characterized by Rabi oscillation. It is concluded that this approach can be applied to other physical systems as well.

arXiv:1904.11642•Review of Scientific Instruments•May 1, 2019•46 citations

Magnetic field stabilization system for atomic physics experiments

B. Merkel, K. Thirumalai, J. E. Tarlton +4 more

Atomic physics experiments commonly use millitesla-scale magnetic fields to provide a quantization axis. As atomic transition frequencies depend on the magnitude of this field, many experiments require a stable absolute field. Most setups use electromagnets, which require a power supply stability not usually met by commercially available units. We demonstrate the stabilization of a field of 14.6 mT to 4.3 nT rms noise (0.29 ppm), compared to noise of >100 nT without any stabilization. The rms noise is measured using a field-dependent hyperfine transition in a single 43Ca+ ion held in a Paul trap at the center of the magnetic field coils. For the 43Ca+ “atomic clock” qubit transition at 14.6 mT, which depends on the field only in second order, this would yield a projected coherence time of many hours. Our system consists of a feedback loop and a feedforward circuit that control the current through the field coils and could easily be adapted to other field amplitudes, making it suitable for other applications such as neutral atom traps.

arXiv:1808.03310•Review of Scientific Instruments•Apr 1, 2019•59 citations
We report the development of an ultralow-noise bipolar current source based on the configuration of H-bridge current switching. The measured relative current noise fluctuation reaches 4 × 10-9 Hz-1/2, which enables an ultra-stable magnetic system for cold atom experiments. We avoid the influence of the AC leakage currents induced by the large parasitic capacitance of the H-bridge. First, the current sensor is placed as close as possible to the magnetic coils so that the systematic errors from these leakage currents are minimized. Second, the large parasitic capacitance, which parallels the magnetic coils and forms an LC oscillator, is removed from the feedback loop in our setup to maintain a large self-resonance frequency of the feedback control loop. These two improvements lead to a current source that is more precise and less noisy. Remarkably, the lowest current noise density produced by the proposed method is only 500 nA Hz-1/2 at a current of 100 A, which is about ten fold smaller than the case with leakage current. To optimize the feedback control, a numerical simulation is implemented by using Matlab Simulink, and the numerical simulation results are entirely consistent with the experimental results.
In various leading-edge ultracold atom experiments in fields such as quantum simulation, quantum computing, and quantum precision measurement, precise and fast control of the magnetic field is important and a current source with a low noise level and high control bandwidth is required. Conventional commercial current sources, even the expensive ones, may not meet the requirements. Here, we present a battery-powered current source (BPCS) solution that has a maximum output of 100 A with a root-mean-square noise of about only 0.35 mA (integrated from 1 Hz to 3 MHz) and a control bandwidth of about 10 kHz. The large output current is sourced from a lead-acid battery, a fluxgate current sensor is used to detect the output current, and fast feedback regulation is done by using an insulated-gate bipolar transistor under the control of an analog proportional-integral controller. The battery power method eliminates the switching noise. A prepulse method is applied to shorten the settling time when the current steps down from a high level to a low level that is close to zero. These features make the BPCS a suitable analog-controlled floating current source for cold-atom experiments such as the preparation of a single 2D quantum gas and optical lattice atomic clocks.
Abstract In ultracold quantum gases, the interactions between the individual atoms can be controlled by applying magnetic bias fields. As magnetic field fluctuations limit the precision here, typically a feedback loop needs to be employed to regulate the current through a pair of Helmholtz coils. No commercially available magnetic field sensor allows to measure large fields directly with high enough precision, leading to many unsatisfactory solutions being used in experiments. Here, we demonstrate a direct magnetic field stabilization in a regime previously not accessible, using NV centers as the magnetic field sensor. This allows us to measure and stabilize fields of 4.66 mT down to 12 nT RMS noise over the course of 24 h, measured on a 1 Hz bandwidth. We achieve a control of better than 1 ppm after 20 min of integration time, ensuring high long-term stability for experiments. This approach extends direct magnetic field control to strong magnetic fields, which could enable new precise quantum simulations in this regime.
Cold atom experiments usually need a controllable and low-noise bias magnetic field to provide a quantization axis. Most labs need home-made stabilization of the field according to the actual setup, as commercially available power supply cannot directly satisfy their requirements. Here, by measuring the field fluctuations and active feedback modulating current supply of the applied magnetic field, we successfully demonstrate a field of 10.58 G with a stability to the level of 2.8 × 10−7 in a duration of 5 min. The root mean square noise is reduced to 0.05 mG, compared to the noise of 1.3 mG without stabilization. The coherence time of the magnetic-field sensitive transition between the rubidium ground states F=1,mF=−1 and 1,0, as measured by Rabi oscillation, is extended to 19.2 ms from the unstabilized value of 1.3 ms. This result is long enough for most experiments on quantum simulation and precision measurement. As our system has no passive magnetic shielding and additional compensation coils, it is highly simple and compact to provide the stable magnetic field and would be adapted to various applications with cold atoms.
Abstract Transition-edge sensors (TESs) are sensitive devices for detecting photons from millimeter radiation to γ rays. Their photon counting efficiency and collecting area benefit from large-array multiplexing scheme, and therefore the development of multiplexing readout system has been an important topic in this field. Among the many multiplex techniques, time-division multiplexing (TDM) superconducting quantum interference device (SQUID) has been used most widely for TES readout. In this work, we design a Configurable Ultra-Low Noise Current Source (CLCS) for TES characterization and as a part of a whole TDM-TES bias control system. The CLCS is based on the feedback structure of ultra-low noise instrumentation amplifiers and low-noise, high-resolution (20 bits) digital-to-analog converter (DAC). CLCS has an ultra-high resolution of 10 nA in the 0 to 5 mA current output range, and can perform current-voltage (IV) sweep and bias-step tests to measure key TES parameters on board. The feedback structure of the CLCS also avoids the issue of impedance mismatch.
A ultralow noise magnetic field is essential for many branches of scientific research. Examples include experiments conducted on ultracold atoms, quantum simulations, and precision measurements. In ultracold atom experiments specifically, a bias magnetic field will often serve as a quantization axis and be applied for Zeeman splitting. As atomic states are usually sensitive to magnetic fields, a magnetic field characterized by ultralow noise as well as high stability is typically required for experimentation. For this study, a bias magnetic field is successfully stabilized at 14.5 G, with the root mean square value of the noise reduced to 18.5 μG (1.28 ppm) by placing μ-metal magnetic shields together with a dynamical feedback circuit. Long-time instability is also regulated consistently below 7 μG. The level of noise exhibited in the bias magnetic field is further confirmed by evaluating the coherence time of a Bose-Einstein condensate characterized by Rabi oscillation. It is concluded that this approach can be applied to other physical systems as well.
Atomic physics experiments commonly use millitesla-scale magnetic fields to provide a quantization axis. As atomic transition frequencies depend on the magnitude of this field, many experiments require a stable absolute field. Most setups use electromagnets, which require a power supply stability not usually met by commercially available units. We demonstrate the stabilization of a field of 14.6 mT to 4.3 nT rms noise (0.29 ppm), compared to noise of >100 nT without any stabilization. The rms noise is measured using a field-dependent hyperfine transition in a single 43Ca+ ion held in a Paul trap at the center of the magnetic field coils. For the 43Ca+ “atomic clock” qubit transition at 14.6 mT, which depends on the field only in second order, this would yield a projected coherence time of many hours. Our system consists of a feedback loop and a feedforward circuit that control the current through the field coils and could easily be adapted to other field amplitudes, making it suitable for other applications such as neutral atom traps.