Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Analysis and suppression of the polarization error for the optical rotation detection system in an atomic comagnetometer

Jiong Huang, Zhuo Wang, Wenfeng Fan, Xing Li, Weijia Zhang, Lihong Duan, Wei Quan

Published Oct 30, 2020• 46 citations
Publisher

Abstract

This paper investigates the laser polarization error in the optical rotation detection system (ORDS) of an atomic comagnetometer (ACM), which will seriously degrade the long-term performance of the ORDS. We first establish an optical transmission model of the ORDS by using Jones matrix concerning the optical imperfection of polarizers. Then, we analyze the polarization error based on this model and propose a novel error suppression method. Finally, we experimentally test the long-term performance of the ORDS and the ACM before and after the polarization error suppression to verify the effectiveness of the proposed method. The experimental results show that the long-term performance of the ORDS and the ACM can be improved by approximately 3.4 times with the proposed polarization error suppression method.

DOI
10.1364/oe.406073

Related papers

Ultrasensitive Optical Rotation Detection With Closed-Loop Suppression of Spin Polarization Error

Xing Heng, Kai Wei, Tian Zhao +6 more

Optical rotation detection system (ORDS) utilizing quantum nondemolition (QND) measurement methods is widely applied in the field of quantum metrology and quantum information. However, the sensitivity of ORDS is limited by the uncertainty from optical-couple noise during the measurement of the atomic spin ensemble. In this study, we specifically analyze the mechanism of optical-couple noise caused by the fluctuations of probe light’s polarization in the modulated ORDS with a new model established to describe atomic spin precession in this particular condition. It is discovered that transverse electron-spin polarization errors are generated by the residual probe photon spin polarization in the ORDS, which results in extra coupling magnetic noise. In order to suppress this noise, a novel in situ method is proposed that the resultant electron-spin errors are reduced by a specifically designed closed-loop system. The results are verified through the ORDS in a co-magnetometer. After zeroing the extra probe photon spin polarization, an angular sensitivity better than$1 \times 10 ^{\mathrm {-8}}$rad/Hz$^{\mathrm {1/2}}$is achieved for frequencies higher than 5 Hz, demonstrating a probe background noise of 0.26 fT/Hz$^{\mathrm {1/2}}$@14.5 Hz, approaching electronic noise and photon shot noise (PSN). With closed-loop control, the optical rotation bias instability is promoted by 4.2 times (from 107.9 to$25.7 \mu $rad/h), and the angular noise of the ORDS is reduced by 2.4 times at 1–100 Hz. The measurement uncertainty of the realized ORDS nears the standard quantum limit, paving the road for long-term ultrasensitive measurements for new physics explorations.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2023•19 citations

Analysis and suppression of the misalignment error for the pumping laser in the atomic comagnetometer

Jiong Huang, Wenfeng Fan, Zhuo Wang +5 more

The misalignment error of the pumping laser in the atomic comagnetometer (ACM) dramatically diminishes the efficiency of the optical pumping process (characterized by the polarization of the hybrid atomic spin ensembles containing electron spins and nuclear spins) and deteriorates the performance of the ACM (characterized by the Allan standard deviation). In this work, a steady-state response model considering the misalignment error of the pumping laser is established and an in-situ evaluation method for this error is proposed. Based on the evaluation method, the influence of this misalignment error on the pumping efficiency and the performance of the ACM is quantitatively analyzed. Furthermore, a pumping laser alignment method based on the second harmonic of a single-beam magnetometer is then proposed, whose effectiveness is verified by experiments. The experimental results show that compared to the original ACM with the severely misaligned pumping laser, the polarization of the hybrid atomic spin ensembles of the ACM with the pumping laser aligned by the proposed method is increased by about 19%, and the corresponding Allan variance at 100s is reduced by about 40%.

Optics Express•Feb 7, 2022•30 citations

Suppression of the magnetic noise response caused by elliptically polarized light in an optical rotation detection system

Bozheng Xing, Jixi Lu, Chang Sun +4 more

We analyze and suppress the magnetic noise response in optical rotation detection system (ORDS) in atomic magnetometers in this study. Because of the imperfections of the optical elements, the probe light is actually elliptically polarized in ORDS, which can polarize the atom ensemble and cause the responses to the three-axis magnetic noise. We theoretically analyze the frequency responses to the magnetic noise, and prove that the responses are closely associated with the DC magnetic field. The values of the DC magnetic fields are calculated with special frequency points, called 'break points', in the transverse responses. We reveal the relationships between the DC magnetic field and the sensitivities of ORDS, and effectively suppress the magnetic noise responses with the residual magnetic field compensation. Finally, the sensitivity of ORDS is improved by approximately two times at 10-20 Hz.

Optics Express•Jan 14, 2022•18 citations

Analysis and Suppression of Optical-Magnetic Misalignment in an Atomic Comagnetometer

Ze Cai, Lihong Duan, Kai Zhang +5 more

Ultrasensitive atomic comagnetometers (ACMs) are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this article, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness is verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response (AFR) of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002 Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the ACMs.

IEEE Sensors Journal•Nov 18, 2024•3 citations

Atomic spin precession detection method based on the Mach-Zehnder interferometer in an atomic comagnetometer

Weijia Zhang, Lihong Duan, Wenfeng Fan +1 more

A new method for the detection of atomic spin precession based on the Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. Different from the conventional polarization detection methods which obtain the atomic spin precession signal by measuring the change of the probe laser power, the proposed method uses the laser modulated by an electro-optic phase modulator (EOM) as the source of the interferometer, and obtains the atomic spin precession signal by measuring the phase difference between the two arms of the MZI. The output of interferometer is independent of the probe laser power, which avoids the system error caused by the fluctuation of the probe laser power, and the long-term stability of the system is effectively improved. At the same time, the method adopts high-frequency electro-optic modulation, which can effectively suppress low-frequency noise, such as 1/f noise, and can significantly improve the detection sensitivity. The rotation sensitivity and long-term stability of the atomic comagnetometer were tested using the MZI detection method and a typical detection method, respectively. The comparison results show that the proposed method has the highest low frequency sensitivity and the potential to improve the long-term stability of the system.

Optics Express•Dec 6, 2022•6 citations

Common-mode noise reduction in an atomic spin gyroscope using optical differential detection

Lihong Duan, Wei Quan, Liwei Jiang +4 more

Optical rotation of linearly polarized light is used to measure atom spin precession in an atomic spin gyroscope (ASG). However, the common-mode noise in the polarization measurement seriously affects the performance of the sensitive ASG. Here we propose an optical differential detection method based on the photoelastic polarization modulation, which could effectively eliminate the light power fluctuation of the laser source and optical elements, while removing the polarization noise and the residual birefringence. The feasibility and efficiency of this method have been verified experimentally. The rotation sensitivity of the ASG is an order of magnitude better, and the long-time stability is significantly improved. In addition, this method is easier to implement because noise sources do not need to be strictly distinguished.

Applied Optics•Sep 19, 2017•16 citations
This paper investigates the laser polarization error in the optical rotation detection system (ORDS) of an atomic comagnetometer (ACM), which will seriously degrade the long-term performance of the ORDS. We first establish an optical transmission model of the ORDS by using Jones matrix concerning the optical imperfection of polarizers. Then, we analyze the polarization error based on this model and propose a novel error suppression method. Finally, we experimentally test the long-term performance of the ORDS and the ACM before and after the polarization error suppression to verify the effectiveness of the proposed method. The experimental results show that the long-term performance of the ORDS and the ACM can be improved by approximately 3.4 times with the proposed polarization error suppression method.
Optical rotation detection system (ORDS) utilizing quantum nondemolition (QND) measurement methods is widely applied in the field of quantum metrology and quantum information. However, the sensitivity of ORDS is limited by the uncertainty from optical-couple noise during the measurement of the atomic spin ensemble. In this study, we specifically analyze the mechanism of optical-couple noise caused by the fluctuations of probe light’s polarization in the modulated ORDS with a new model established to describe atomic spin precession in this particular condition. It is discovered that transverse electron-spin polarization errors are generated by the residual probe photon spin polarization in the ORDS, which results in extra coupling magnetic noise. In order to suppress this noise, a novel in situ method is proposed that the resultant electron-spin errors are reduced by a specifically designed closed-loop system. The results are verified through the ORDS in a co-magnetometer. After zeroing the extra probe photon spin polarization, an angular sensitivity better than1×10−81 \times 10 ^{\mathrm {-8}}1×10−8rad/Hz1/2^{\mathrm {1/2}}1/2is achieved for frequencies higher than 5 Hz, demonstrating a probe background noise of 0.26 fT/Hz1/2^{\mathrm {1/2}}1/2@14.5 Hz, approaching electronic noise and photon shot noise (PSN). With closed-loop control, the optical rotation bias instability is promoted by 4.2 times (from 107.9 to$25.7 \mu $rad/h), and the angular noise of the ORDS is reduced by 2.4 times at 1–100 Hz. The measurement uncertainty of the realized ORDS nears the standard quantum limit, paving the road for long-term ultrasensitive measurements for new physics explorations.
The misalignment error of the pumping laser in the atomic comagnetometer (ACM) dramatically diminishes the efficiency of the optical pumping process (characterized by the polarization of the hybrid atomic spin ensembles containing electron spins and nuclear spins) and deteriorates the performance of the ACM (characterized by the Allan standard deviation). In this work, a steady-state response model considering the misalignment error of the pumping laser is established and an in-situ evaluation method for this error is proposed. Based on the evaluation method, the influence of this misalignment error on the pumping efficiency and the performance of the ACM is quantitatively analyzed. Furthermore, a pumping laser alignment method based on the second harmonic of a single-beam magnetometer is then proposed, whose effectiveness is verified by experiments. The experimental results show that compared to the original ACM with the severely misaligned pumping laser, the polarization of the hybrid atomic spin ensembles of the ACM with the pumping laser aligned by the proposed method is increased by about 19%, and the corresponding Allan variance at 100s is reduced by about 40%.
We analyze and suppress the magnetic noise response in optical rotation detection system (ORDS) in atomic magnetometers in this study. Because of the imperfections of the optical elements, the probe light is actually elliptically polarized in ORDS, which can polarize the atom ensemble and cause the responses to the three-axis magnetic noise. We theoretically analyze the frequency responses to the magnetic noise, and prove that the responses are closely associated with the DC magnetic field. The values of the DC magnetic fields are calculated with special frequency points, called 'break points', in the transverse responses. We reveal the relationships between the DC magnetic field and the sensitivities of ORDS, and effectively suppress the magnetic noise responses with the residual magnetic field compensation. Finally, the sensitivity of ORDS is improved by approximately two times at 10-20 Hz.
Ultrasensitive atomic comagnetometers (ACMs) are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this article, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness is verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response (AFR) of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002 Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the ACMs.
A new method for the detection of atomic spin precession based on the Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. Different from the conventional polarization detection methods which obtain the atomic spin precession signal by measuring the change of the probe laser power, the proposed method uses the laser modulated by an electro-optic phase modulator (EOM) as the source of the interferometer, and obtains the atomic spin precession signal by measuring the phase difference between the two arms of the MZI. The output of interferometer is independent of the probe laser power, which avoids the system error caused by the fluctuation of the probe laser power, and the long-term stability of the system is effectively improved. At the same time, the method adopts high-frequency electro-optic modulation, which can effectively suppress low-frequency noise, such as 1/f noise, and can significantly improve the detection sensitivity. The rotation sensitivity and long-term stability of the atomic comagnetometer were tested using the MZI detection method and a typical detection method, respectively. The comparison results show that the proposed method has the highest low frequency sensitivity and the potential to improve the long-term stability of the system.
Optical rotation of linearly polarized light is used to measure atom spin precession in an atomic spin gyroscope (ASG). However, the common-mode noise in the polarization measurement seriously affects the performance of the sensitive ASG. Here we propose an optical differential detection method based on the photoelastic polarization modulation, which could effectively eliminate the light power fluctuation of the laser source and optical elements, while removing the polarization noise and the residual birefringence. The feasibility and efficiency of this method have been verified experimentally. The rotation sensitivity of the ASG is an order of magnitude better, and the long-time stability is significantly improved. In addition, this method is easier to implement because noise sources do not need to be strictly distinguished.