Y. Nakashima, Fuminori Hirayama, Satoshi Kohjiro, Hirotake Yamamori, Shuichi Nagasawa, Akira Sato, Shinya Yamada, Ryota Hayakawa, Noriko Y. Yamasaki, Kazuhisa Mitsuda, K. Nagayoshi, Hiroki Akamatsu, Luciano G. Gottardi, E. Taralli, M. P. Bruijn, M. Ridder, J. R. Gao, Jan-Willem den Herder
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of 0.9 μΦ0/Hz (where Φ0 is the magnetic flux quantum), equivalent to 9 pA/Hz. By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and ∼2 μΦ0/Hz readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around 12 μs. We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a ∼10% contribution of readout noise, i.e., 0.9–1.7 eV.
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of 0.9 μΦ0/Hz (where Φ0 is the magnetic flux quantum), equivalent to 9 pA/Hz. By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and ∼2 μΦ0/Hz readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around 12 μs. We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a ∼10% contribution of readout noise, i.e., 0.9–1.7 eV.
We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we have developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics are evaluated, and the results have shown that the distortion of the SQUID characteristics and the degradation of its noise performance are not clearly observed. Finally, we have developed an MW-Mux microstrip SQUID with a low current noise of <; 20 pA/√(Hz) which is below the typical noise of our TES X-ray microcalorimeter, 30 pA/√(Hz).
Abstract A microwave SQUID multiplexer ( μ MUX) with a high multiplexing factor is a promising readout approach for large-scale superconducting transition-edge sensor (TES) bolometer arrays. This paper reports on the characteristics of 16-channel μ MUX prototype chips and a 60-channel readout module developed to read out TES bolometers for the Ali cosmic microwave background polarization telescope (AliCPT). We designed two different coupling structures between the resonator and the radio-frequency superconducting interference device: design A with a mutual inductance ( M T ) of 2.3 pH and design B with an M T of 6.5 pH. For design A, the mean resonator bandwidth ( Δ f BW ) and peak-to-peak frequency shift ( Δ f pp ) are approximately 610 kHz and 290 kHz, respectively. The measured mean open-loop current noise is less than 40 pA / Hz . Preliminary results indicate that crosstalk between adjacent channels is below 1% in our design A μ MUX chip. A measured channel with design B shows a Δ f BW of 586 kHz and a current noise of 33 pA / Hz , similar to the design A channels. In comparison, the Δ f pp of 803 kHz is much larger than the design A channels due to a larger M T . The readout module, consisting of two design A chips and two design B chips, shows 60 resonances, corresponding to a yield of 94%. In the future, we will place 32 design A channels within the same chip dimension to increase the channel density and build a larger readout module suitable for AliCPT TES arrays.
This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.
Superconducting transition-edge sensors (TESs) with high sensitivity can detect electromagnetic wave radiations from millimeter/submillimeter, optical to x/γ rays, and have been successfully used in many fields. To improve detection efficiency and sensitivity, large-scale TES arrays are required in combination with multiplexing readout electronics. Compared to other multiplexing schemes, microwave SQUID multiplexing (μMUX), consisting of high-quality microwave superconducting resonators and RF SQUIDs, is most suitable since it provides a wider bandwidth (GHz) and consequently higher multiplexing factor. We designed two types of circuits with different mutual inductances (MT) between the resonator and the RF SQUID: 2.3 pH for the weak-coupling channel and 6.5 pH for the strong- coupling channel. The resonator and RF SQUID washers made of 150 nm Nb are first fabricated by magnetron-sputtering and reactive ion etching (RIE), followed by deposition of Nb/Al-AlOx/Nb trilayer and definition of the Josephson junctions of the RF SQUIDs. This work presents a μMUX demonstration chip with five channels with Q1values of 787 and 3626, and the measured frequency shifts (Δfpp) of ∼500 kHz and 4 MHz for the weak- and strong-coupling channels, respectively. The open-loop equivalent noise current, obtained from the measured phase noise and resonator responsivity, is ∼80 pA/ √Hz with the strong-coupling channel.
Abstract We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ( μ MUX) prototype for transition-edge sensor readout in the Ricochet experiment. The device consists of aluminum coplanar-waveguide resonators and RF superconducting quantum interference devices with Dolan-style Al/AlO x /Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1–1.5 μ Φ 0 / Hz . With flux-ramp modulation, low-frequency 1 / f noise is suppressed, and the flux sensitivity is around 3–4 μ Φ 0 / Hz , corresponding to a current sensitivity of 24–33 pA / Hz at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier between the μ MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3–0.6 μ Φ 0 / Hz and an effective system noise temperature below 1K. These results establish aluminum μ MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.
Dissipationless microwave radio frequency superconducting interference device (RF-SQUID) multiplexers are attractive for readouts of large format arrays of transition edge sensors (TES). This multiplexer has the potential for readout bandwidth of several GHz and power consumption of ≈0.1 pW per pixel, which are ≈103 and ≈10-4 times as large as those of DC-SQUID-based conventional multiplexers. To evaluate their readout performance for TES photon counters ranging from near infrared to gamma ray, white noise of this multiplexer was experimentally studied at 4 K. The reason for this was, firstly, to avoid the low-frequency fluctuation obvious at around 0.1 K but trivial for the energy resolution of photon counters, and secondly for a feasibility study of readout operation at 4 K for extended applications. To increase resonant Q at 4 K and maintain low-noise SQUID operation, multiplexer chips consisting of niobium nitride (NbN)-based coplanar-waveguide resonators and niobium (Nb)-based RF-SQUIDs have been developed. This hybrid multiplexer exhibited 1×104≤QI≤2×104 and the square root of spectral density of current noise referred to the SQUID input √SI =31 pA/√Hz, where QI is the internal Q of resonators. The former and the latter are factor-of-five and seven improvements from our previous results on Nb-based resonators, respectively. Systematic noise measurement with various microwave readout power PMR and two-directional readout on the complex plane of transmission component of scattering matrix S21 makes the contribution of each noise source obvious. By decreasing these noises to the degree achievable by current technology, we predicted the microwave RF-SQUID multiplexer would exhibit √SI ≤5 pA/√Hz; i.e., close to √SI of state-of-the-art DC-SQUID-based multiplexers.