arXiv:2303.04181 · Applied Physics Letters

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

M. Malnou, J. A. B. Mates, Michael R. Vissers, Leila R. Vale, Daniel R. Schmidt, D. A. Bennett, J. Gao, Joel N. Ullom

Published May 22, 2023• 12 citations
arXivHTMLPDF

Abstract

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μΦ0/Hz with the KITWPA off to 0.77 μΦ0/Hz with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μΦ0/Hz to 0.2 μΦ0/Hz. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. The combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

DOI
10.1063/5.0149646

Related papers

Low-noise microwave SQUID multiplexed readout of 38 x-ray transition-edge sensor microcalorimeters

Y. Nakashima, Fuminori Hirayama, Satoshi Kohjiro +15 more

We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of 0.9 μΦ0/Hz (where Φ0 is the magnetic flux quantum), equivalent to 9 pA/Hz. By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and ∼2 μΦ0/Hz readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around 12 μs. We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a ∼10% contribution of readout noise, i.e., 0.9–1.7 eV.

Applied Physics Letters•Sep 21, 2020•26 citations

Kinetic Inductance Traveling Wave Amplifier Designs for Practical Microwave Readout Applications

Andrea Giachero, Michael R. Vissers, Jordan Wheeler +6 more

Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.

arXiv:2403.11354•Journal of Low Temperature Physics•Apr 5, 2024•15 citations

Demonstration of a microwave SQUID multiplexer with pre-amplification from a kinetic inductance traveling-wave parametric amplifier

Michael R. Vissers, M. Malnou, Jiansong Gao +7 more

Kinetic inductance traveling-wave parametric amplifiers (KITs) are under development for the read out of large cryogenic detector arrays. We present new KIT designs based on 20nm NbTiN films patterned by use of standard optical photolithography. We report device gain, bandwidth, and noise properties, which approach the quantum limit. In addition, we demonstrate a KIT preamplifier with a microwave SQUID multiplexer. The improved input referred current noise, as compared to standard HEMT readout, opens up new possibilities for cryogenic receivers. We discuss these benefits.

Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI•Dec 12, 2020•6 citations

Characterization of aluminum microwave SQUID multiplexers for CE ν NS detection

James Amidei, A. Armatol, C. Augier +92 more

Abstract We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ( μ MUX) prototype for transition-edge sensor readout in the Ricochet experiment. The device consists of aluminum coplanar-waveguide resonators and RF superconducting quantum interference devices with Dolan-style Al/AlO x /Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1–1.5 μ Φ 0 / Hz . With flux-ramp modulation, low-frequency 1 / f noise is suppressed, and the flux sensitivity is around 3–4 μ Φ 0 / Hz , corresponding to a current sensitivity of 24–33 pA / Hz at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier between the μ MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3–0.6 μ Φ 0 / Hz and an effective system noise temperature below 1K. These results establish aluminum μ MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

arXiv:2605.24272•Superconductor Science and Technology•Oct 1, 2026•0 citations

Microwave SQUID multiplexer for readout of transition-edge sensor array

Zhi-Fa Feng, Xin-Kai Yang, Wen Zhang +9 more

Superconducting transition-edge sensors (TESs) are highly sensitive detectors and can detect electromagnetic wave radiations from millimeter/submillimeter, optical to 𝑥/γrays, suitable for cosmology, astrophysics, quantum information, and biosensing. In principle, thousands of TESs even more are required to enhance the detection efficiency for large-scale survey. Among other multiplexing schemes, microwave SQUID multiplexer (μMUX), consisting of resonators and RF SQUIDs, has a bandwidth of several GHz, thus multiplexing factor on the order of thousands, more suitable for readout of large TES arrays. We designed and fabricated superconducting coplanar waveguide (CPW) resonators with a high qualityfactor and second-order gradient RF SQUID with two inductive coupling structures respectively. Then, we optimized the critical current density of the Josephson junction and measured the mutual inductance parameters of the second-order gradient structure SQUID, which are consistent with the simulation results. Finally, we fabricated a cryogenic μMUX chip based on RF SQUID and resonator. We discussed the results of the development of μMUX in more detail.

Infrared, Millimeter-Wave, and Terahertz Technologies•Oct 12, 2023•0 citations

Development of Microwave SQUID Multiplexer for Readout of Transition-Edge Sensor Array

Zhi-Fa Feng, Xianfeng Zhou, Wen Zhang +12 more

Superconducting transition-edge sensors (TESs) with high sensitivity can detect electromagnetic wave radiations from millimeter/submillimeter, optical to x/γ rays, and have been successfully used in many fields. To improve detection efficiency and sensitivity, large-scale TES arrays are required in combination with multiplexing readout electronics. Compared to other multiplexing schemes, microwave SQUID multiplexing (μMUX), consisting of high-quality microwave superconducting resonators and RF SQUIDs, is most suitable since it provides a wider bandwidth (GHz) and consequently higher multiplexing factor. We designed two types of circuits with different mutual inductances (MT) between the resonator and the RF SQUID: 2.3 pH for the weak-coupling channel and 6.5 pH for the strong- coupling channel. The resonator and RF SQUID washers made of 150 nm Nb are first fabricated by magnetron-sputtering and reactive ion etching (RIE), followed by deposition of Nb/Al-AlOx/Nb trilayer and definition of the Josephson junctions of the RF SQUIDs. This work presents a μMUX demonstration chip with five channels with Q1values of 787 and 3626, and the measured frequency shifts (Δfpp) of ∼500 kHz and 4 MHz for the weak- and strong-coupling channels, respectively. The open-loop equivalent noise current, obtained from the measured phase noise and resonator responsivity, is ∼80 pA/ √Hz with the strong-coupling channel.

IEEE Transactions on Applied Superconductivity•Jan 14, 2026•2 citations
We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μΦ0/Hz with the KITWPA off to 0.77 μΦ0/Hz with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μΦ0/Hz to 0.2 μΦ0/Hz. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. The combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of 0.9 μΦ0/Hz (where Φ0 is the magnetic flux quantum), equivalent to 9 pA/Hz. By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and ∼2 μΦ0/Hz readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around 12 μs. We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a ∼10% contribution of readout noise, i.e., 0.9–1.7 eV.
Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.
Kinetic inductance traveling-wave parametric amplifiers (KITs) are under development for the read out of large cryogenic detector arrays. We present new KIT designs based on 20nm NbTiN films patterned by use of standard optical photolithography. We report device gain, bandwidth, and noise properties, which approach the quantum limit. In addition, we demonstrate a KIT preamplifier with a microwave SQUID multiplexer. The improved input referred current noise, as compared to standard HEMT readout, opens up new possibilities for cryogenic receivers. We discuss these benefits.
Abstract We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ( μ MUX) prototype for transition-edge sensor readout in the Ricochet experiment. The device consists of aluminum coplanar-waveguide resonators and RF superconducting quantum interference devices with Dolan-style Al/AlO x /Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1–1.5 μ Φ 0 / Hz . With flux-ramp modulation, low-frequency 1 / f noise is suppressed, and the flux sensitivity is around 3–4 μ Φ 0 / Hz , corresponding to a current sensitivity of 24–33 pA / Hz at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier between the μ MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3–0.6 μ Φ 0 / Hz and an effective system noise temperature below 1K. These results establish aluminum μ MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.
Superconducting transition-edge sensors (TESs) are highly sensitive detectors and can detect electromagnetic wave radiations from millimeter/submillimeter, optical to 𝑥/γrays, suitable for cosmology, astrophysics, quantum information, and biosensing. In principle, thousands of TESs even more are required to enhance the detection efficiency for large-scale survey. Among other multiplexing schemes, microwave SQUID multiplexer (μMUX), consisting of resonators and RF SQUIDs, has a bandwidth of several GHz, thus multiplexing factor on the order of thousands, more suitable for readout of large TES arrays. We designed and fabricated superconducting coplanar waveguide (CPW) resonators with a high qualityfactor and second-order gradient RF SQUID with two inductive coupling structures respectively. Then, we optimized the critical current density of the Josephson junction and measured the mutual inductance parameters of the second-order gradient structure SQUID, which are consistent with the simulation results. Finally, we fabricated a cryogenic μMUX chip based on RF SQUID and resonator. We discussed the results of the development of μMUX in more detail.
Superconducting transition-edge sensors (TESs) with high sensitivity can detect electromagnetic wave radiations from millimeter/submillimeter, optical to x/γ rays, and have been successfully used in many fields. To improve detection efficiency and sensitivity, large-scale TES arrays are required in combination with multiplexing readout electronics. Compared to other multiplexing schemes, microwave SQUID multiplexing (μMUX), consisting of high-quality microwave superconducting resonators and RF SQUIDs, is most suitable since it provides a wider bandwidth (GHz) and consequently higher multiplexing factor. We designed two types of circuits with different mutual inductances (MT) between the resonator and the RF SQUID: 2.3 pH for the weak-coupling channel and 6.5 pH for the strong- coupling channel. The resonator and RF SQUID washers made of 150 nm Nb are first fabricated by magnetron-sputtering and reactive ion etching (RIE), followed by deposition of Nb/Al-AlOx/Nb trilayer and definition of the Josephson junctions of the RF SQUIDs. This work presents a μMUX demonstration chip with five channels with Q1values of 787 and 3626, and the measured frequency shifts (Δfpp) of ∼500 kHz and 4 MHz for the weak- and strong-coupling channels, respectively. The open-loop equivalent noise current, obtained from the measured phase noise and resonator responsivity, is ∼80 pA/ √Hz with the strong-coupling channel.