Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Absolute calibration of the sensitivity of photodetectors using a biphotonic field

А. А. Малыгин, Alexander N. Penin, Alexander V. Sergienko

Published May 1, 1981• 18 citations
OpenAlex

Related papers

Absolute calibration of analog photodetectors using a biphoton field

Alexander V. Sergienko, Alexander N. Penin

Technical Physics Letters•Jul 1, 1986•0 citations

Research on Absolute Calibration of Photodetector Quantum-Efficiency Using Entangled Photons

吕亮 Lü Liang, 张寅超 Zhang Yinchao, 林延东 Lin Yandong

Acta Optica Sinica•Jan 1, 2012•4 citations

Sensitivity of photodetectors for Poissonian and Gaussian photon statistics

V. B. Fedorov, V. G. Mityakov

RaT•Apr 1, 1985•0 citations

ABSOLUTE CALIBRATION OF PHOTODETECTORS BASED ON SPONTANEOUS PARAMETRIC DOWN-CONVERSION BIPHOTON FIELD

L. J. Sun, Zhiyu Yang

A new method of absolute calibration of photodetector sensitivity based on spontaneous parametric down\|conversion(SPDC) biphoton field is described.The process of SPDC is studied theoretically.The single photon detection probability and two\|photon coincidence probability are derived and the calibration principle for photodetectors is explained.An experimental system has been set up.The sensitivity of a photon\|counting photomultiplier tube was measured,and the results were compared with those obtained using conventional method.

Acta Physica Sinica•Jan 1, 2000•0 citations

ABSOLUTE CALIBRATION OF PHOTODETECTORS BASED ON SPONTANEOUS PARAMETRIC DOWN CONVERSION BIPHOTON FIELD

Sun Li

A new method of absolute calibration of photodetector′s sensitivity based on spontaneous parametric down conversion (SPDC) biphoton field is discussed.The process of SPDC is studied theoretically.An experimental system has been set up. The sensitivity of a photon counting photomultiplier tube was measured, and the results were compared with that obtained using conventional method.

Journal of Applied Optics•Jan 1, 1999•0 citations

Open-system theory of photodetection

Annabella Selloni, P. Schwendimann, A. Quattropani +1 more

Optics Communications•Aug 1, 1977•6 citations
A new method of absolute calibration of photodetector sensitivity based on spontaneous parametric down\|conversion(SPDC) biphoton field is described.The process of SPDC is studied theoretically.The single photon detection probability and two\|photon coincidence probability are derived and the calibration principle for photodetectors is explained.An experimental system has been set up.The sensitivity of a photon\|counting photomultiplier tube was measured,and the results were compared with those obtained using conventional method.