Acta Physica Sinica

ABSOLUTE CALIBRATION OF PHOTODETECTORS BASED ON SPONTANEOUS PARAMETRIC DOWN-CONVERSION BIPHOTON FIELD

L. J. Sun, Zhiyu Yang

Published Jan 1, 2000• 0 citations
OpenAlex

Abstract

A new method of absolute calibration of photodetector sensitivity based on spontaneous parametric down\|conversion(SPDC) biphoton field is described.The process of SPDC is studied theoretically.The single photon detection probability and two\|photon coincidence probability are derived and the calibration principle for photodetectors is explained.An experimental system has been set up.The sensitivity of a photon\|counting photomultiplier tube was measured,and the results were compared with those obtained using conventional method.

Related papers

ABSOLUTE CALIBRATION OF PHOTODETECTORS BASED ON SPONTANEOUS PARAMETRIC DOWN CONVERSION BIPHOTON FIELD

Sun Li

A new method of absolute calibration of photodetector′s sensitivity based on spontaneous parametric down conversion (SPDC) biphoton field is discussed.The process of SPDC is studied theoretically.An experimental system has been set up. The sensitivity of a photon counting photomultiplier tube was measured, and the results were compared with that obtained using conventional method.

Journal of Applied Optics•Jan 1, 1999•0 citations

Absolute measurement of photodetector quantum efficiency based on spontaneous parametric down-conversion biphoton field

Liqun Sun, Yanpeng Zhang, Tiantong Tang +2 more

A new method of absolute measurement of photodetector quantum efficiency based on spontaneous parametric down- conversion (SPDC) biphoton field is discussed. The process of SPDC is studied theoretically. The single photon detection probability and two-photon coincidence probability are derived and the measurement principle of photodetectors is explained. An experimental system has been set up. The quantum efficiency of a photon-counting photomultiplier tube was measured, and the results were compared with that obtained using conventional method.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 4, 1999•0 citations

Absolute standardless calibration of photodetectors based on quantum two-photon fields

Alexander N. Penin, Alexander V. Sergienko

A new method of absolute calibration of photodetectors based on a nonclassical effect in nonlinear optics is discussed. The combined influence of a monochromatic flux of pump photons and quantum vacuum noise on a nonlinear crystal with no center of symmetry results in the appearance of rigorously correlated pairs of photons with continuous spectral distribution in the spontaneous parametric scattering of light (spontaneous parametric downconversion) process. The presence of an optical field in a broad spectral range created by the two-photon states (biphotons) makes it possible to develop a new method of measuring the spectral distribution of the absolute value of the quantum efficiency of photodetectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources (étalons). The feasibility of the method is demonstrated on different types of photomultiplier tube.

Applied Optics•Sep 1, 1991•65 citations

STUDY ON THE ABSOLUTE MEASUREMENT METHOD OF INFRARED SPECTRAL RADIANCE

Li Sun

The generation mechanism of spontaneous parametric down conversion(SPDC)biphoton field is discussed theoretically.The correlated photons produced in the SPDC process have been used in the absolute measurement of infrared spectral radiance.The measurement principle and method are introduced.

Journal of Applied Optics•Jan 1, 1999•0 citations

Absolute calibration of analog detectors using stimulated parametric down conversion

G. Brida, Maria V. Chekhova, Marco Genovese +2 more

Spontaneous parametric down conversion has been largely exploited as a tool for absolute calibration of photon counting detectors, photomultiplier tubes or avalanche photodiodes working in the Geiger regime. In this work we investigate the extension of this technique from very low photon flux of the photon counting regime to the absolute calibration of analog photodetectors at higher photon flux. Moving towards a higher photon rate, i.e. at a high gain regime, the spontaneous parametric down conversion shows the intrinsic limitations of the method, while the stimulated parametric down conversion process, where a seed beam is properly injected into the crystal in order to increase the photon generation rate in the conjugate arm, allows us to work around this problem. A preliminary uncertainty budget is discussed.

arXiv:0802.0346•Journal of Modern Optics•Nov 11, 2008•12 citations

Research in absolute calibration of single photon detectors by means of correlated photons

Yu Feng, Xiaobing Zheng, Jianjun Li +1 more

There are two general methods in radiometric calibration of detectors, one is based on radiation sources and the other based on detectors. Because the two methods need to establish a primary standard of high precision and a transfer chain, precision of the standard will be reduced by extension of the chain. A new calibration method of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal, without needing transfer chain. Using 351.1-nm output of a tunable laser to pump 'beta'-barium borate (BBO) crystal, an absolute calibration experimental system of single photon detectors based on correlated photons is performed. The quantum efficiency of photomultiplier (PMT) at 702.2 nm is measured by the setup. Advantages of this method over traditional methods are also pointed out by comparison.

Chinese Optics Letters•Jun 10, 2006•1 citation
A new method of absolute calibration of photodetector sensitivity based on spontaneous parametric down|conversion(SPDC) biphoton field is described.The process of SPDC is studied theoretically.The single photon detection probability and two|photon coincidence probability are derived and the calibration principle for photodetectors is explained.An experimental system has been set up.The sensitivity of a photon|counting photomultiplier tube was measured,and the results were compared with those obtained using conventional method.
A new method of absolute measurement of photodetector quantum efficiency based on spontaneous parametric down- conversion (SPDC) biphoton field is discussed. The process of SPDC is studied theoretically. The single photon detection probability and two-photon coincidence probability are derived and the measurement principle of photodetectors is explained. An experimental system has been set up. The quantum efficiency of a photon-counting photomultiplier tube was measured, and the results were compared with that obtained using conventional method.
A new method of absolute calibration of photodetectors based on a nonclassical effect in nonlinear optics is discussed. The combined influence of a monochromatic flux of pump photons and quantum vacuum noise on a nonlinear crystal with no center of symmetry results in the appearance of rigorously correlated pairs of photons with continuous spectral distribution in the spontaneous parametric scattering of light (spontaneous parametric downconversion) process. The presence of an optical field in a broad spectral range created by the two-photon states (biphotons) makes it possible to develop a new method of measuring the spectral distribution of the absolute value of the quantum efficiency of photodetectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources (étalons). The feasibility of the method is demonstrated on different types of photomultiplier tube.
Spontaneous parametric down conversion has been largely exploited as a tool for absolute calibration of photon counting detectors, photomultiplier tubes or avalanche photodiodes working in the Geiger regime. In this work we investigate the extension of this technique from very low photon flux of the photon counting regime to the absolute calibration of analog photodetectors at higher photon flux. Moving towards a higher photon rate, i.e. at a high gain regime, the spontaneous parametric down conversion shows the intrinsic limitations of the method, while the stimulated parametric down conversion process, where a seed beam is properly injected into the crystal in order to increase the photon generation rate in the conjugate arm, allows us to work around this problem. A preliminary uncertainty budget is discussed.
There are two general methods in radiometric calibration of detectors, one is based on radiation sources and the other based on detectors. Because the two methods need to establish a primary standard of high precision and a transfer chain, precision of the standard will be reduced by extension of the chain. A new calibration method of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal, without needing transfer chain. Using 351.1-nm output of a tunable laser to pump 'beta'-barium borate (BBO) crystal, an absolute calibration experimental system of single photon detectors based on correlated photons is performed. The quantum efficiency of photomultiplier (PMT) at 702.2 nm is measured by the setup. Advantages of this method over traditional methods are also pointed out by comparison.