RaEl

The noise of rapid-action superconductor bolometers

A. D. Tkachenko, I. A. Khrebtov

Published Jan 1, 1990• 0 citations
OpenAlex

Related papers

Normal metal–insulator–superconductor junction technology for bolometers

Daniel R. Schmidt, William Duncan, K. D. Irwin +3 more

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Jan 5, 2006•5 citations

Superconductive bolometers for submillimeter wavelengths

John L. Clarke, G. I. Hoffer, P. L. Richards +1 more

Three types of composite superconductive bolometers are described in which the temperature-sensitive element is a superconducting film at the transition temperature, a superconductor–normal metal–superconductor Josephson junction, or a superconductor–insulator–normal metal quasiparticle tunneling junction. The temperature-sensitive element is evaporated onto a sapphire substrate on the reverse side of which is a bismuth film to absorb the submillimeter radiation. The noise limitations of each type of bolometer are calculated. The fabrication and measured performance of the transition-edge bolometer and the Josephson-junction bolometer are described. The best electrical (noise-equivalent power) NEP obtained with a transition-edge bolometer fabricated on a 4×4×0.005-mm sapphire substrate is (1.7±0.1) ×10−15 W Hz−1/2 at 2 Hz at an operating temperature of 1.27 K. This NEP is within a factor of 2 of the thermal noise limit. The effective absorptivity of the bismuth film is measured to be 0.47±0.05, and the corresponding detectivity D* is calculated to be (1.1±0.1) ×1014 cm W−1 Hz1/2. Suggestions are made for further improvements in sensitivity.

Journal of Applied Physics•Dec 1, 1977•139 citations

Investigation of the low-frequency noise of a superconducting bolometer

Г. А. Зайцев, I. A. Khrebtov

RaEl•May 1, 1978•0 citations

Superconducting noise bolometer as a direct detector

Andrew G. Semenov, Heinz‐Wilhelm Hübers, K. Ilin +2 more

•Jan 1, 2005•0 citations

Analysys of the concept of a superconducing bolometer with rf readout

Nikolay N. Abramov

The concept of a superconducting transition-edge bolometer with rf readout, which was proposed in a number of earlier publications, is analyzed. It is shown that such a device cannot in fact operate at the edge of the superconducting transition, and nonequilibrium effects in the superconductor play the major role in its response to the electromagnetic action. A mathematical model is developed, which explains qualitatively the experimental results reported earlier and indicating an unstable response to the action of a readout (pump) signal. The possibility of obtaining a stable response with an optimal choice of parameters of the device is also demonstrated.

Technical Physics•Feb 1, 2016•0 citations

Fast-response superconducting electronic bolometer

Eugene M. Gershenzon, Murray Gershenzon, Gregory N Gol'tsman +2 more

Technical Physics Letters•Feb 1, 1989•0 citations
Three types of composite superconductive bolometers are described in which the temperature-sensitive element is a superconducting film at the transition temperature, a superconductor–normal metal–superconductor Josephson junction, or a superconductor–insulator–normal metal quasiparticle tunneling junction. The temperature-sensitive element is evaporated onto a sapphire substrate on the reverse side of which is a bismuth film to absorb the submillimeter radiation. The noise limitations of each type of bolometer are calculated. The fabrication and measured performance of the transition-edge bolometer and the Josephson-junction bolometer are described. The best electrical (noise-equivalent power) NEP obtained with a transition-edge bolometer fabricated on a 4×4×0.005-mm sapphire substrate is (1.7±0.1) ×10−15 W Hz−1/2 at 2 Hz at an operating temperature of 1.27 K. This NEP is within a factor of 2 of the thermal noise limit. The effective absorptivity of the bismuth film is measured to be 0.47±0.05, and the corresponding detectivity D* is calculated to be (1.1±0.1) ×1014 cm W−1 Hz1/2. Suggestions are made for further improvements in sensitivity.
The concept of a superconducting transition-edge bolometer with rf readout, which was proposed in a number of earlier publications, is analyzed. It is shown that such a device cannot in fact operate at the edge of the superconducting transition, and nonequilibrium effects in the superconductor play the major role in its response to the electromagnetic action. A mathematical model is developed, which explains qualitatively the experimental results reported earlier and indicating an unstable response to the action of a readout (pump) signal. The possibility of obtaining a stable response with an optimal choice of parameters of the device is also demonstrated.