EPJ Quantum Technology

Second-order effects in parametric-resonance magnetometers based on atomic alignment

François Beato, Agustin Palacios-Laloy

Published May 7, 2020• 17 citations
Publisher

Abstract

Optically-pumped magnetometers (OPM) based on parametric resonance allow real-time tri-axial measurement of very small magnetic fields with a single optical access to the gas cell. Most of these magnetometers rely on circularly polarized pumping light. We focus here on the ones relying on linearly polarized light, yielding atomic alignment. For these magnetometers we investigate three second order effects which appear in the usual regimes of operation, so to clarify if they translate to metrological problems like systematic errors or increased noise. The first of these effects is the breakdown of the three-step approach when the optical beam has a large intensity. The second one is the breakdown of the rotating wave approximation when the frequencies of the RF fields are not much larger than the rates of other atomic processes. The third one is the tensor light-shift which appears when the light is slightly detuned from resonance. This work should help to clarify the accuracy reachable with OPM, which is an important question notably for medical imaging applications.

DOI
10.1140/epjqt/s40507-020-00083-7

Related papers

Zero-field magnetometry based on the combination of atomic orientation and alignment

Gwenael Le Gal, Agustin Palacios-Laloy

Optically pumped magnetometers usually rely on optical pumping using circularly or linearly polarized light. We study here zero-field magnetometers pumped with elliptically polarized light, preparing both atomic orientation and alignment with complementary geometries. We start by extending the three-step approach for elliptically polarized pumping. This allows us to study the Hanle effect in elliptical polarization by comparing the analytical absorption signals with experiments made on $^{4}\mathrm{He}$ metastable state. We then study parametric resonance magnetometers based on elliptical polarization by using the dressed-atom formalism with one and two radio-frequency fields. The results show good agreement with the experimental measurements and interesting perspectives for magnetometry where symmetry breaking by pumping light is mitigated.

arXiv:2112.04262•Physical Review A•Apr 25, 2022•13 citations

Theory of a He4 parametric-resonance magnetometer based on atomic alignment

François Beato, Élie Belorizky, Étienne Labyt +2 more

In parametric-resonance magnetometers (PRMs), optically pumped atoms subject to rf fields allow one to measure the components of a very low magnetic field. Here, instead of using a circularly polarized light for creating atomic orientation, as in previous works, a linearly polarized light is used for creating atomic alignment. A dressed-atom formalism introduced by Polonsky and Cohen-Tannoudji is extended and allows one to map this situation to a simpler Hanle effect on aligned atoms. Analytical expressions for all alignment tensor components and photodetection signals are obtained for both the Hanle magnetometer and PRMs. A two-rf field alignment PRM is shown to display several improvements from its orientation counterpart, providing a secular third axis sensitivity and a lower degradation from the one-axis sensitivity obtained by using a single rf field. These specificities are shown to result from the apparent depolarization of the pumping light acting on the atom dressed by two-rf fields. Experimental measurements showing a good agreement with the theoretical predictions are presented.

Physical Review A•Nov 26, 2018•43 citations

Spin noise spectroscopy of an alignment-based atomic magnetometer

M. Koźbiał, L. Elson, Lucas M. Rushton +4 more

Optically pumped magnetometers (OPMs) are revolutionizing the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturization which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin polarized through optical pumping with circular or linear polarized light, respectively. Characterization of OPMs and the dynamical properties of their noise is important for applications in real-time sensing tasks. In our work, we experimentally perform spin noise spectroscopy of an alignment-based magnetometer. Moreover, we propose a stochastic model that predicts the noise power spectra exhibited by the device when, apart from the strong magnetic field responsible for the Larmor precession of the spin, white noise is applied in the perpendicular direction aligned with the pumping-probing beam. By varying the strength of the noise applied as well as the linear-polarization angle of incoming light, we verify the model to accurately predict the heights of the Larmor-induced spectral peaks and their corresponding linewidths. Our work paves the way for alignment-based magnetometers to become operational in real-time sensing tasks. Published by the American Physical Society 2024

arXiv:2312.05577•Physical Review A•Jul 30, 2024•20 citations

矢量光在光泵磁强计中的研究及应用

孟小勤 Meng Xiaoqin, 童叶 Tong Ye, 徐燕 Xu Yan +1 more

Significance Optically pumped magnetometers (OPMs) are crucial in magnetic-field measurements. Its high sensitivity and low noise allow it to detect weak magnetic-field changes up to the nT level, thus significantly expanding human understanding into the micro-magnetic-field environment. OPMs are beneficial in various areas, including the precise mapping of Earth’s magnetic field, the detection of weak biological magnetic signals within biological tissues, quantum computing, and magnetic-material research.The main function of an OPM is to detect magnetic fields using specific polarized pump light and detection light. High-purity pump light, which is typically linearly or circularly polarized, interacts with atomic cells. The selective excitation of pump light causes the arrangement of atomic magnetic moments to align with the polarization direction of light, thus forming a magnetized region. This process is known as optical pumping, which effectively places atoms in specific magnetic quantum states, thereby enhancing their sensitivity to magnetic fields. This allows the detection of light passing through magnetized regions with different polarization states. Under the effect of a magnetic field, the energy levels of atoms undergo Zeeman splitting, which affects the absorption and scattering of detection light. By analyzing and detecting changes in light intensity or polarization rotation, the intensity and direction of the magnetic field can be inferred accurately. The polarization state must be controlled precisely as it determines the manner by which atoms are excited and their response to magnetic fields, thereby ensuring the high sensitivity and measurement accuracy of the equipment. This principle based on atomic magnetic resonance renders the OPM an ideal tool for detecting weak magnetic fields; thus, OPMs are widely used in scientific research and practical applications.Aided by the development of modern technology, researchers have comprehensively investigated vector lights with complex polarization states and gradually applied them to OPMs. In an OPM, particularly the component involving the interaction between vector light and atoms, dichroism and birefringence are two key optical phenomena. Dichroism refers to the different propagation characteristics of light in different polarization directions. This characteristic is used to selectively excite or manipulate atoms of specific energy levels in an OPM. Birefringence refers to the difference in the refractive index between vertically and horizontally polarized light in a medium, which causes a beam to separate when it passes through an atomic medium. By leveraging the properties above and examining the practical application of vector light in OPMs, we can further improve the sensitivity of OPMs. Compared with conventional OPMs, a new type of OPM based on vector light pumping/detection features rapid response, adaptability to more complex environments, and high sensitivity. Owing to the vector characteristics of vector light, this OPM can simultaneously measure multiple components of the magnetic field, thus achieving complete magnetic-field vector measurements without requiring additional optical paths. Therefore, it is more suitable for integration into complex optical systems in fields such as biomedical, material science, and space exploration. Progress This paper summarizes the development history of OPMs, describes their operating principle (Figs. 2 and 3), and explains the energy-level transition of optically pumped polarized alkali metal atoms based on a 87Rb atomic energy-level diagram (Fig. 4). As per the development history of OPMs, optical polarization is crucial to the entire process (Fig. 5). Vector light is a new type of beam that has emerged in recent years, and its polarization state is distributed in a certain pattern on the cross-section of the beam (Fig. 6). The measurement of vector light in a magnetic field has been investigated extensively (Fig. 7). In terms of light and matter, investigating the dichroism and birefringence in the interaction between vector light and alkali metal atoms is crucial for OPMs. Based on dichroism, when a beam of linearly polarized light is irradiated onto an alkali metal atomic-gas chamber, the absorption and scattering efficiency of light varies owing to the ultrafine structure of the atoms and the energy levels of different magnetic quantum numbers. By adjusting the polarization direction of light, atoms can be more effectively pumped into specific magnetic states, thereby enhancing their response to magnetic fields (Fig. 8). Based on birefringence, vector light is incident in the orthogonal pumping direction, and the relationship between the polarization rotation angle of the detected light and the external magnetic field after the light passes through the gas chamber can be derived (Fig. 9). In practical applications, vector light with complex polarization states can be used as pump/detection light not only for the real-time dynamic detection of the magnetic-field size (Fig. 10) but also for solving the “dead zone” problem in magnetometers, improving spatial resolution and sensitivity (Fig. 11), and achieving miniaturized OPMs. Conclusions and Prospects Comprehensive investigations into quantum optics and the development of micro- and nano-technology will refine the manipulation of vector light, which is expected to enable magnetic-field measurements with higher sensitivities and resolutions. New OPMs based on vector optical pumping/detection have gradually received the attention of researchers. Thus, the application of OPMs in biomedicine, geological exploration, quantum information processing, and other fields will be promoted. Additionally, the miniaturization and integrated design of OPMs render them more portable and will further broaden their practical use. In the future, the development of vector-light technology will significantly improve OPMs.

Chinese Journal of Lasers•Jan 1, 2024•3 citations

Measurement and cancellation of light shift in optically pumped magnetometers

Rujie Li, Wei Quan, Wenfeng Fan +1 more

Light shift arising from the circularly polarized pump beam in atomic magnetometers can induce an undesired magnetic response, and thus affect their accuracy. Here, the light shift and the corresponding cross-talk effect in the magnetometer have been investigated, and a scheme with an additional off-resonant pump beam with an appropriate polarization and intensity has been proposed to effectively reject the light shift. And the experimental results reproduce the expected behavior. This scheme provides a powerful tool to reject the light shift in optical pumping systems, in particular, the hybrid optically pumped systems.

Europhysics Letters (EPL)•Mar 1, 2018•14 citations

Zero-field optical magnetometer based on spin alignment

Adil Meraki, L. Elson, N.J. Ho +4 more

Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.

arXiv:2308.12233•Physical Review A•Dec 11, 2023•20 citations
Optically-pumped magnetometers (OPM) based on parametric resonance allow real-time tri-axial measurement of very small magnetic fields with a single optical access to the gas cell. Most of these magnetometers rely on circularly polarized pumping light. We focus here on the ones relying on linearly polarized light, yielding atomic alignment. For these magnetometers we investigate three second order effects which appear in the usual regimes of operation, so to clarify if they translate to metrological problems like systematic errors or increased noise. The first of these effects is the breakdown of the three-step approach when the optical beam has a large intensity. The second one is the breakdown of the rotating wave approximation when the frequencies of the RF fields are not much larger than the rates of other atomic processes. The third one is the tensor light-shift which appears when the light is slightly detuned from resonance. This work should help to clarify the accuracy reachable with OPM, which is an important question notably for medical imaging applications.
Optically pumped magnetometers usually rely on optical pumping using circularly or linearly polarized light. We study here zero-field magnetometers pumped with elliptically polarized light, preparing both atomic orientation and alignment with complementary geometries. We start by extending the three-step approach for elliptically polarized pumping. This allows us to study the Hanle effect in elliptical polarization by comparing the analytical absorption signals with experiments made on 4He^{4}\mathrm{He}4He metastable state. We then study parametric resonance magnetometers based on elliptical polarization by using the dressed-atom formalism with one and two radio-frequency fields. The results show good agreement with the experimental measurements and interesting perspectives for magnetometry where symmetry breaking by pumping light is mitigated.
In parametric-resonance magnetometers (PRMs), optically pumped atoms subject to rf fields allow one to measure the components of a very low magnetic field. Here, instead of using a circularly polarized light for creating atomic orientation, as in previous works, a linearly polarized light is used for creating atomic alignment. A dressed-atom formalism introduced by Polonsky and Cohen-Tannoudji is extended and allows one to map this situation to a simpler Hanle effect on aligned atoms. Analytical expressions for all alignment tensor components and photodetection signals are obtained for both the Hanle magnetometer and PRMs. A two-rf field alignment PRM is shown to display several improvements from its orientation counterpart, providing a secular third axis sensitivity and a lower degradation from the one-axis sensitivity obtained by using a single rf field. These specificities are shown to result from the apparent depolarization of the pumping light acting on the atom dressed by two-rf fields. Experimental measurements showing a good agreement with the theoretical predictions are presented.
Optically pumped magnetometers (OPMs) are revolutionizing the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturization which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin polarized through optical pumping with circular or linear polarized light, respectively. Characterization of OPMs and the dynamical properties of their noise is important for applications in real-time sensing tasks. In our work, we experimentally perform spin noise spectroscopy of an alignment-based magnetometer. Moreover, we propose a stochastic model that predicts the noise power spectra exhibited by the device when, apart from the strong magnetic field responsible for the Larmor precession of the spin, white noise is applied in the perpendicular direction aligned with the pumping-probing beam. By varying the strength of the noise applied as well as the linear-polarization angle of incoming light, we verify the model to accurately predict the heights of the Larmor-induced spectral peaks and their corresponding linewidths. Our work paves the way for alignment-based magnetometers to become operational in real-time sensing tasks. Published by the American Physical Society 2024
Significance Optically pumped magnetometers (OPMs) are crucial in magnetic-field measurements. Its high sensitivity and low noise allow it to detect weak magnetic-field changes up to the nT level, thus significantly expanding human understanding into the micro-magnetic-field environment. OPMs are beneficial in various areas, including the precise mapping of Earth’s magnetic field, the detection of weak biological magnetic signals within biological tissues, quantum computing, and magnetic-material research.The main function of an OPM is to detect magnetic fields using specific polarized pump light and detection light. High-purity pump light, which is typically linearly or circularly polarized, interacts with atomic cells. The selective excitation of pump light causes the arrangement of atomic magnetic moments to align with the polarization direction of light, thus forming a magnetized region. This process is known as optical pumping, which effectively places atoms in specific magnetic quantum states, thereby enhancing their sensitivity to magnetic fields. This allows the detection of light passing through magnetized regions with different polarization states. Under the effect of a magnetic field, the energy levels of atoms undergo Zeeman splitting, which affects the absorption and scattering of detection light. By analyzing and detecting changes in light intensity or polarization rotation, the intensity and direction of the magnetic field can be inferred accurately. The polarization state must be controlled precisely as it determines the manner by which atoms are excited and their response to magnetic fields, thereby ensuring the high sensitivity and measurement accuracy of the equipment. This principle based on atomic magnetic resonance renders the OPM an ideal tool for detecting weak magnetic fields; thus, OPMs are widely used in scientific research and practical applications.Aided by the development of modern technology, researchers have comprehensively investigated vector lights with complex polarization states and gradually applied them to OPMs. In an OPM, particularly the component involving the interaction between vector light and atoms, dichroism and birefringence are two key optical phenomena. Dichroism refers to the different propagation characteristics of light in different polarization directions. This characteristic is used to selectively excite or manipulate atoms of specific energy levels in an OPM. Birefringence refers to the difference in the refractive index between vertically and horizontally polarized light in a medium, which causes a beam to separate when it passes through an atomic medium. By leveraging the properties above and examining the practical application of vector light in OPMs, we can further improve the sensitivity of OPMs. Compared with conventional OPMs, a new type of OPM based on vector light pumping/detection features rapid response, adaptability to more complex environments, and high sensitivity. Owing to the vector characteristics of vector light, this OPM can simultaneously measure multiple components of the magnetic field, thus achieving complete magnetic-field vector measurements without requiring additional optical paths. Therefore, it is more suitable for integration into complex optical systems in fields such as biomedical, material science, and space exploration. Progress This paper summarizes the development history of OPMs, describes their operating principle (Figs. 2 and 3), and explains the energy-level transition of optically pumped polarized alkali metal atoms based on a 87Rb atomic energy-level diagram (Fig. 4). As per the development history of OPMs, optical polarization is crucial to the entire process (Fig. 5). Vector light is a new type of beam that has emerged in recent years, and its polarization state is distributed in a certain pattern on the cross-section of the beam (Fig. 6). The measurement of vector light in a magnetic field has been investigated extensively (Fig. 7). In terms of light and matter, investigating the dichroism and birefringence in the interaction between vector light and alkali metal atoms is crucial for OPMs. Based on dichroism, when a beam of linearly polarized light is irradiated onto an alkali metal atomic-gas chamber, the absorption and scattering efficiency of light varies owing to the ultrafine structure of the atoms and the energy levels of different magnetic quantum numbers. By adjusting the polarization direction of light, atoms can be more effectively pumped into specific magnetic states, thereby enhancing their response to magnetic fields (Fig. 8). Based on birefringence, vector light is incident in the orthogonal pumping direction, and the relationship between the polarization rotation angle of the detected light and the external magnetic field after the light passes through the gas chamber can be derived (Fig. 9). In practical applications, vector light with complex polarization states can be used as pump/detection light not only for the real-time dynamic detection of the magnetic-field size (Fig. 10) but also for solving the “dead zone” problem in magnetometers, improving spatial resolution and sensitivity (Fig. 11), and achieving miniaturized OPMs. Conclusions and Prospects Comprehensive investigations into quantum optics and the development of micro- and nano-technology will refine the manipulation of vector light, which is expected to enable magnetic-field measurements with higher sensitivities and resolutions. New OPMs based on vector optical pumping/detection have gradually received the attention of researchers. Thus, the application of OPMs in biomedicine, geological exploration, quantum information processing, and other fields will be promoted. Additionally, the miniaturization and integrated design of OPMs render them more portable and will further broaden their practical use. In the future, the development of vector-light technology will significantly improve OPMs.
Light shift arising from the circularly polarized pump beam in atomic magnetometers can induce an undesired magnetic response, and thus affect their accuracy. Here, the light shift and the corresponding cross-talk effect in the magnetometer have been investigated, and a scheme with an additional off-resonant pump beam with an appropriate polarization and intensity has been proposed to effectively reject the light shift. And the experimental results reproduce the expected behavior. This scheme provides a powerful tool to reject the light shift in optical pumping systems, in particular, the hybrid optically pumped systems.
Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.