arXiv:2312.05577 · Physical Review A

Spin noise spectroscopy of an alignment-based atomic magnetometer

M. Koźbiał, L. Elson, Lucas M. Rushton, Ali Akbar, Adil Meraki, Kasper Jensen, Jan Kołodyński

Published Jul 30, 2024• 15 citations
arXivHTMLPDF

Abstract

Optically pumped magnetometers (OPMs) are revolutionizing the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturization which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin polarized through optical pumping with circular or linear polarized light, respectively. Characterization of OPMs and the dynamical properties of their noise is important for applications in real-time sensing tasks. In our work, we experimentally perform spin noise spectroscopy of an alignment-based magnetometer. Moreover, we propose a stochastic model that predicts the noise power spectra exhibited by the device when, apart from the strong magnetic field responsible for the Larmor precession of the spin, white noise is applied in the perpendicular direction aligned with the pumping-probing beam. By varying the strength of the noise applied as well as the linear-polarization angle of incoming light, we verify the model to accurately predict the heights of the Larmor-induced spectral peaks and their corresponding linewidths. Our work paves the way for alignment-based magnetometers to become operational in real-time sensing tasks. Published by the American Physical Society 2024

DOI
10.1103/physreva.110.013125

Related papers

Spin projection noise and the magnetic sensitivity of optically pumped magnetometers

K. Mouloudakis, V. Koutrouli, Iannis K. Kominis +2 more

Present protocols for obtaining the ultimate magnetic sensitivity of optically pumped magnetometers (OPMs) utilizing alkali-metal ensembles rely on uncorrelated atoms in stretched states. A new approach for calculating the spin projection noise (SPN)-limited signal to noise ratio (SNR) and the magnetic sensitivity of OPMs is proposed. Our model is based solely on the mean-field density matrix dynamics and in contrast to previous models, it applies to both low and high field regimes, it takes into account the degree of spin polarization, the intra- and interhyperfine correlations, the decoherence processes, the atom-light coupling and the effects of the spin dynamics on the spin-noise spectra. Fine tuning of the probe frequency allow us to explore different hyperfine states and ground-state correlations. Especially in the spin-exchange-relaxation-free (SERF) regime, alongside the magnetic resonance narrowing and the increased number density, hallmarks of SERF magnetometers, we report on a new SERF feature; the reduction of spin-projection noise at the spin precession frequency as a consequence of strongly-correlated hyperfine spins that attenuate and redistribute SPN when properly probed.

arXiv:2402.10746•Feb 16, 2024•0 citations

Zero-field optical magnetometer based on spin alignment

Adil Meraki, L. Elson, N.J. Ho +4 more

Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.

arXiv:2308.12233•Physical Review A•Dec 11, 2023•19 citations

Second-order effects in parametric-resonance magnetometers based on atomic alignment

François Beato, Agustin Palacios-Laloy

Abstract Optically-pumped magnetometers (OPM) based on parametric resonance allow real-time tri-axial measurement of very small magnetic fields with a single optical access to the gas cell. Most of these magnetometers rely on circularly polarized pumping light. We focus here on the ones relying on linearly polarized light, yielding atomic alignment. For these magnetometers we investigate three second order effects which appear in the usual regimes of operation, so to clarify if they translate to metrological problems like systematic errors or increased noise. The first of these effects is the breakdown of the three-step approach when the optical beam has a large intensity. The second one is the breakdown of the rotating wave approximation when the frequencies of the RF fields are not much larger than the rates of other atomic processes. The third one is the tensor light-shift which appears when the light is slightly detuned from resonance. This work should help to clarify the accuracy reachable with OPM, which is an important question notably for medical imaging applications.

EPJ Quantum Technology•May 7, 2020•17 citations

Spectral analysis of spin noise in an optically spin-polarized stochastic Bloch equation driven by noisy magnetic fields

M. M. Kim, Sangkyung Lee

We theoretically analyze an optically spin-polarized collection of atoms, which serves as a basis for atomic sensors. Assuming that the intrinsic atomic spin projection noise is negligible, we provide the closed-form autocorrelation function and the power spectral density (PSD) of the solution to a noisy version of an optically pumped Bloch equation, wherein each component of the external magnetic field is subjected to white noise. We conclude that noise in the bias B-field direction does not affect the autocorrelation function, up to first order in white noise covariance amplitudes. Moreover, the noise terms for the remaining two axes make different contributions to the magnetic noise-driven spin PSD; in particular, the contribution corresponding to noises perpendicular to the probing direction dominates at high frequencies. Some results concerning the second (and higher)-order terms are given. In particular, we anticipate a decrease in the effective Larmor frequency despite an increase in the magnetic field magnitude in the case of anisotropic transversal B-field noises. The analytic results are supported by Monte Carlo simulations employing the Euler–Maruyama method. The analytic methodology is applied to the case of a Bell–Bloom magnetometer, which reveals a non-linearity in the PSD of the magnetometer output and also a broadening effect due to magnetic field noise.

arXiv:2302.03275•AIP Advances•Feb 1, 2024•2 citations

Optically Pumped Magnetometer and Its Application

Jixi Lu, Yao Chen

The optically pumped magnetometer (OPM) is a class of atomic devices that rely on the measurement of Larmor precession of an atomic spin ensemble in a magnetic field. They need the specific frequency light to complete the pumping and detection process. OPMs typically work under the Earth's magnetic field or a limited field. When operating in near-zero field, they can realize the spin-exchange relaxation-free (SERF) regime, thereby promoting a substantial increase in sensitivity. At present, OPMs have been widely used in magnetoencephalography, magnetocardiography, geomagnetic detection, and inertia measurement (comagnetometer). There are a large number of researchers engaged in the study of relevant mechanisms, devices, technologies, and applications. More importantly, supported by MEMS technology and micro/nano optics, OPMs have the potential to move toward chip-scale sensors. This special issue contains some latest developments in OPMs and related areas. We hope the reprint can provide valuable references for researchers in the related field.

MDPI eBooks•Jul 31, 2025•0 citations

All-Optical Broadband Atomic Magnetometer Utilizing Raman-Driven Spin Noise Spectroscopy

Sayari Majumder, Saptarishi Chaudhuri

We report the development and performance of an atomic magnetometer (AM) utilizing the Raman-driven spin noise spectroscopy (RDSNS) technique, which measures the intrinsic spin fluctuations of an atomic medium subjected to a coherent two-photon optical drive. The RDSNS signal is noninvasively detected using a far-off resonant weak probe light utilizing a polarimetric detection scheme. This overcomes the limitations of the small dynamic range and low bandwidth of traditional optically pumped magnetometers (OPMs) or AMs operating in the spin exchange relaxation-free (SERF) regime. We experimentally demonstrate, using both paraffin-coated and buffer-gas-filled vapor cell containing neutral rubidium atoms, that the dynamic range of such magnetometers can reach beyond 150 G while maintaining a dc magnetometer resolution of around 30 pT and a magnetic noise sensitivity of around$30~\text {pT}/\sqrt {\text {Hz}}$at a bandwidth of 100 Hz and a magnetic field of about 0.6 mT. Being an all-optical setup, this instrument is largely immune to interference with stray radio frequency fields and has the potential to be miniaturized and field deployable. One of the practical applications would be to measure variations in geomagnetic fields precisely without having to shield the magnetometer.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•6 citations
Optically pumped magnetometers (OPMs) are revolutionizing the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturization which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin polarized through optical pumping with circular or linear polarized light, respectively. Characterization of OPMs and the dynamical properties of their noise is important for applications in real-time sensing tasks. In our work, we experimentally perform spin noise spectroscopy of an alignment-based magnetometer. Moreover, we propose a stochastic model that predicts the noise power spectra exhibited by the device when, apart from the strong magnetic field responsible for the Larmor precession of the spin, white noise is applied in the perpendicular direction aligned with the pumping-probing beam. By varying the strength of the noise applied as well as the linear-polarization angle of incoming light, we verify the model to accurately predict the heights of the Larmor-induced spectral peaks and their corresponding linewidths. Our work paves the way for alignment-based magnetometers to become operational in real-time sensing tasks. Published by the American Physical Society 2024
Present protocols for obtaining the ultimate magnetic sensitivity of optically pumped magnetometers (OPMs) utilizing alkali-metal ensembles rely on uncorrelated atoms in stretched states. A new approach for calculating the spin projection noise (SPN)-limited signal to noise ratio (SNR) and the magnetic sensitivity of OPMs is proposed. Our model is based solely on the mean-field density matrix dynamics and in contrast to previous models, it applies to both low and high field regimes, it takes into account the degree of spin polarization, the intra- and interhyperfine correlations, the decoherence processes, the atom-light coupling and the effects of the spin dynamics on the spin-noise spectra. Fine tuning of the probe frequency allow us to explore different hyperfine states and ground-state correlations. Especially in the spin-exchange-relaxation-free (SERF) regime, alongside the magnetic resonance narrowing and the increased number density, hallmarks of SERF magnetometers, we report on a new SERF feature; the reduction of spin-projection noise at the spin precession frequency as a consequence of strongly-correlated hyperfine spins that attenuate and redistribute SPN when properly probed.
Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.
Abstract Optically-pumped magnetometers (OPM) based on parametric resonance allow real-time tri-axial measurement of very small magnetic fields with a single optical access to the gas cell. Most of these magnetometers rely on circularly polarized pumping light. We focus here on the ones relying on linearly polarized light, yielding atomic alignment. For these magnetometers we investigate three second order effects which appear in the usual regimes of operation, so to clarify if they translate to metrological problems like systematic errors or increased noise. The first of these effects is the breakdown of the three-step approach when the optical beam has a large intensity. The second one is the breakdown of the rotating wave approximation when the frequencies of the RF fields are not much larger than the rates of other atomic processes. The third one is the tensor light-shift which appears when the light is slightly detuned from resonance. This work should help to clarify the accuracy reachable with OPM, which is an important question notably for medical imaging applications.
We theoretically analyze an optically spin-polarized collection of atoms, which serves as a basis for atomic sensors. Assuming that the intrinsic atomic spin projection noise is negligible, we provide the closed-form autocorrelation function and the power spectral density (PSD) of the solution to a noisy version of an optically pumped Bloch equation, wherein each component of the external magnetic field is subjected to white noise. We conclude that noise in the bias B-field direction does not affect the autocorrelation function, up to first order in white noise covariance amplitudes. Moreover, the noise terms for the remaining two axes make different contributions to the magnetic noise-driven spin PSD; in particular, the contribution corresponding to noises perpendicular to the probing direction dominates at high frequencies. Some results concerning the second (and higher)-order terms are given. In particular, we anticipate a decrease in the effective Larmor frequency despite an increase in the magnetic field magnitude in the case of anisotropic transversal B-field noises. The analytic results are supported by Monte Carlo simulations employing the Euler–Maruyama method. The analytic methodology is applied to the case of a Bell–Bloom magnetometer, which reveals a non-linearity in the PSD of the magnetometer output and also a broadening effect due to magnetic field noise.
The optically pumped magnetometer (OPM) is a class of atomic devices that rely on the measurement of Larmor precession of an atomic spin ensemble in a magnetic field. They need the specific frequency light to complete the pumping and detection process. OPMs typically work under the Earth's magnetic field or a limited field. When operating in near-zero field, they can realize the spin-exchange relaxation-free (SERF) regime, thereby promoting a substantial increase in sensitivity. At present, OPMs have been widely used in magnetoencephalography, magnetocardiography, geomagnetic detection, and inertia measurement (comagnetometer). There are a large number of researchers engaged in the study of relevant mechanisms, devices, technologies, and applications. More importantly, supported by MEMS technology and micro/nano optics, OPMs have the potential to move toward chip-scale sensors. This special issue contains some latest developments in OPMs and related areas. We hope the reprint can provide valuable references for researchers in the related field.
We report the development and performance of an atomic magnetometer (AM) utilizing the Raman-driven spin noise spectroscopy (RDSNS) technique, which measures the intrinsic spin fluctuations of an atomic medium subjected to a coherent two-photon optical drive. The RDSNS signal is noninvasively detected using a far-off resonant weak probe light utilizing a polarimetric detection scheme. This overcomes the limitations of the small dynamic range and low bandwidth of traditional optically pumped magnetometers (OPMs) or AMs operating in the spin exchange relaxation-free (SERF) regime. We experimentally demonstrate, using both paraffin-coated and buffer-gas-filled vapor cell containing neutral rubidium atoms, that the dynamic range of such magnetometers can reach beyond 150 G while maintaining a dc magnetometer resolution of around 30 pT and a magnetic noise sensitivity of around30 pT/Hz30~\text {pT}/\sqrt {\text {Hz}}30 pT/Hz​at a bandwidth of 100 Hz and a magnetic field of about 0.6 mT. Being an all-optical setup, this instrument is largely immune to interference with stray radio frequency fields and has the potential to be miniaturized and field deployable. One of the practical applications would be to measure variations in geomagnetic fields precisely without having to shield the magnetometer.