Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Soviet Journal of Quantum Electronics

The effect of radiation statistics on the sensitivity of a fiber ring interferometer

É. I. Alekseev, E. N. Bazarov, Viatcheslav Izraelian, А. В. Кухто

Published Jan 1, 1987• 1 citation
OpenAlex

Related papers

Optical nonreciprocity of a fiber ring interferometer induced by nonstationary processes in the single-mode fiber lightguide

E. I. Bazarov, A. T. Polukhin, E I Sverchkov +1 more

Optics and Spectroscopy•Jul 1, 1983•0 citations

Optimization of the Geometric Phase Sensitivity of an Array of Atom Ring Interferometers

Karina Sandoval-Sanchez, Christian Campo, Tabitha Rivera +1 more

Bulletin of the American Physical Society•Jun 11, 2015•0 citations

Nonlinear Sagnac fiber interferometer based on coherent feedback control

Xiaoyu Feng, Min Nie, Guang Yang

In order to improve the phase sensitivity of nonlinear Sagnac interferometer, a nonlinear Sagnac fiber optic interferometer based on feedback control is designed to improve the phase sensitivity by introducing a feedback control loop into the nonlinear Sagnac interferometer. This design adopts the composite feedback control structure of Nonlinear Beam Splitter (NBS) and Linear Beam Splitter (BS). By adjusting the reflectivity of the Linear Beam Splitter, the intensity of the feedback signal can be effectively changed to regulate the phase sensitivity of the interferometer. The feedback amplified signal light passes through the Sagnac fiber optic ring before being processed by a second NBS for quantum enhancement to further improve the phase sensitivity of the interferometer. The simulation results show that the phase sensitivity of the interferometer with certain feedback strength is better than that without feedback. Especially when the phase difference is π, the phase sensitivity of the interferometer with low and medium feedback strengths is improved by 33.3% and 28.9% respectively; In addition, the gain coefficient of the NBS is a key parameter affecting the performance of the interferometer, and a suitable gain coefficient can further optimize the phase sensitivity of the interferometer.

International Conference on Optoelectronic Information and Optical Engineering (OIOE)•Jun 10, 2025•0 citations

Radiation noise of an active interferometer

Sergei N Bagayev, A. A. Kurbatov, Е. А. Титов

Applied Physics B•Mar 1, 1997•5 citations

Transformation of the radiation fluctuations of a low-coherence source in a two-arm interferometer

Dmitry V. Shabanov

Radiophysics and Quantum Electronics•Apr 1, 2000•1 citation

Sub-shot-noise measurement with fiber-squeezed optical pulses

K. Bergman, Christopher Richard Doerr, H. A. Haus +1 more

A novel scheme employing two pulses separated by a short time delay is used to cancel the phase noise from guided-acoustic-wave Brillouin scattering in a fiber ring interferometer. The dual-pulse-excited fiber ring is used to generate squeezed vacuum that, when injected into a measuring Mach–Zehnder interferometer, improves its sensitivity by 3 dB beyond the shot-noise limit.

Optics Letters•Apr 15, 1993•57 citations
In order to improve the phase sensitivity of nonlinear Sagnac interferometer, a nonlinear Sagnac fiber optic interferometer based on feedback control is designed to improve the phase sensitivity by introducing a feedback control loop into the nonlinear Sagnac interferometer. This design adopts the composite feedback control structure of Nonlinear Beam Splitter (NBS) and Linear Beam Splitter (BS). By adjusting the reflectivity of the Linear Beam Splitter, the intensity of the feedback signal can be effectively changed to regulate the phase sensitivity of the interferometer. The feedback amplified signal light passes through the Sagnac fiber optic ring before being processed by a second NBS for quantum enhancement to further improve the phase sensitivity of the interferometer. The simulation results show that the phase sensitivity of the interferometer with certain feedback strength is better than that without feedback. Especially when the phase difference is π, the phase sensitivity of the interferometer with low and medium feedback strengths is improved by 33.3% and 28.9% respectively; In addition, the gain coefficient of the NBS is a key parameter affecting the performance of the interferometer, and a suitable gain coefficient can further optimize the phase sensitivity of the interferometer.