Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Radiophysics and Quantum Electronics

Transformation of the radiation fluctuations of a low-coherence source in a two-arm interferometer

Dmitry V. Shabanov

Published Apr 1, 2000• 1 citation
Publisher
DOI
10.1007/bf02677197

Related papers

Radiation noise of an active interferometer

Sergei N Bagayev, A. A. Kurbatov, Е. А. Титов

Applied Physics B•Mar 1, 1997•5 citations

Excess broadband noise at equal intensities in the interferometer arms

Valentin M. Gelikonov, Vladimir N. Romashov, Grigory V. Gelikonov

Abstract We report a theoretical and experimental study of the excess photocurrent noise in the detection of low-coherence radiation caused by the beats of the random components of the optical spectrum at equal intensities in the interferometer arms. It is shown that, in this case, the spectral density of photocurrent fluctuations is times higher than when detecting radiation without interference. This result makes it possible to clarify the value of the limiting level of the total fundamental noise of low-coherence radiation during interference. Excess noise cannot be completely subtracted in balanced detection.

Quantum Electronics•Apr 27, 2021•2 citations

Coherent State in an Interferometer

Ray LaPierre

Undergraduate texts in physics•Jan 1, 2022•0 citations

Fourier transform spectroscopy: a tool for quantum optics studies

Gian Giuseppe Bentini, M. Chiarini, Agostino Desalvo

Most of the experimental interferometric setup are based on the Mach-Zehnder geometry. Usually in the experimental configurations the photons travel in air, at a speed v independent of λ. An integrated optics approach appears necessary both for practical applications and because it can be useful for fundamental optics studies because the transmitted photons are in a spatial coherent state. We exploited a hybrid setup integrating optical fibres and monolithic optical waveguides to implement an asymmetric nonlinear Mach-Zehnder Interferometer (ANLI). One arm of the interferometer was equipped with a single mode Er:LiNbO3 waveguide, acting as nonlinear component whereas the other arm was an undoped LiNbO3 single mode waveguide, used to obtain a phase shift through the application of a voltage ramp. We injected in the ANLI a 980 nm laser radiation to collect interferograms that could be ascribed exclusively to the pump photons, as all frequency conversion events are localized only in one arm of the interferometer. The Fourier Transform analysis of the experimental data allowed us to perform a n Interaction-Free Quantum Optics experiment. This is a novel approach that can be used because in quantum mechanics the wave functions of a state, expressed in terms of two conjugate variables, are Fourier Transform pairs. In fact, operating in the Fourier Transform time-frequency space-domain, we recovered the spectral composition, in the wavenumber space-domain, of the photons generated by the excitation of an Er3+ doped crystal placed in one arm of the interferometer.

Italian National Conference on Photonic Technologies (Fotonica)•Jan 1, 2018•0 citations

Coherent Emission Light Source

Robert B. Griffiths, Robert Henry Dicke

A sharp, intense emission line may be obtained by use of resonance radiation coherently scattered from a collimated beam of atoms. The coherently scattered light may be separated from the exciting radiation by placing the atomic beam in one arm of a Mach-Zehnder interferometer or by diffraction from several parallel atomic beam pencils. The latter technique has been tested experimentally by observing hyperfine structure in light coherently scattered from a beam of sodium atoms.

Review of Scientific Instruments•Aug 1, 1957•5 citations

Interferometry with Two Photons

Ricardo Asch Campos

•Jan 1, 1992•0 citations
Abstract We report a theoretical and experimental study of the excess photocurrent noise in the detection of low-coherence radiation caused by the beats of the random components of the optical spectrum at equal intensities in the interferometer arms. It is shown that, in this case, the spectral density of photocurrent fluctuations is times higher than when detecting radiation without interference. This result makes it possible to clarify the value of the limiting level of the total fundamental noise of low-coherence radiation during interference. Excess noise cannot be completely subtracted in balanced detection.
Most of the experimental interferometric setup are based on the Mach-Zehnder geometry. Usually in the experimental configurations the photons travel in air, at a speed v independent of λ. An integrated optics approach appears necessary both for practical applications and because it can be useful for fundamental optics studies because the transmitted photons are in a spatial coherent state. We exploited a hybrid setup integrating optical fibres and monolithic optical waveguides to implement an asymmetric nonlinear Mach-Zehnder Interferometer (ANLI). One arm of the interferometer was equipped with a single mode Er:LiNbO3 waveguide, acting as nonlinear component whereas the other arm was an undoped LiNbO3 single mode waveguide, used to obtain a phase shift through the application of a voltage ramp. We injected in the ANLI a 980 nm laser radiation to collect interferograms that could be ascribed exclusively to the pump photons, as all frequency conversion events are localized only in one arm of the interferometer. The Fourier Transform analysis of the experimental data allowed us to perform a n Interaction-Free Quantum Optics experiment. This is a novel approach that can be used because in quantum mechanics the wave functions of a state, expressed in terms of two conjugate variables, are Fourier Transform pairs. In fact, operating in the Fourier Transform time-frequency space-domain, we recovered the spectral composition, in the wavenumber space-domain, of the photons generated by the excitation of an Er3+ doped crystal placed in one arm of the interferometer.