Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

SU(2)-in-SU(1,1) nested interferometer

Wei Du, Jia Kong, Jun Fang Jia, Sheng Ming, Chun-Hua Yuan, J. F. Chen, Z. Y. Ou, Morgan W. Mitchell, Weiping Zhang

Published Apr 30, 2020• 2 citations
OpenAlex

Abstract

The use of squeezing and entanglement allows advanced interferometers to detect signals that would otherwise be buried in quantum mechanical noise. High sensitivity instruments including magnetometers and gravitational wave detectors have shown enhanced signal-to-noise ratio (SNR) by injecting single-mode squeezed light into SU(2) interferometers, e.g. the Mach-Zehnder or Michelson topologies. The quantum enhancement in this approach is sensitive to losses, which break the fragile quantum correlations in the squeezed state. In contrast, SU(1,1) interferometers achieve quantum enhancement by noiseless amplification; they noiselessly increase the signal rather than reducing the quantum noise. Prior work on SU(1,1) interferometers has shown quantum-enhanced SNR11 and insensitivity to losses but to date has been limited to low powers and thus low SNR. Here we introduce a new interferometer topology, the SU(2)-in-SU(1,1) nested interferometer, that combines quantum enhancement, the high SNR possible with a SU(2) interferometer, and the loss tolerance of the SU(1,1) approach. We implement this interferometer using four-wave mixing in a hot atomic vapor and demonstrate 2:2(5) dB of quantum SNR enhancement, in a system with a phase variance nearly two orders of magnitude below that of any previous loss-tolerant enhancement scheme. The new interferometer enables new possibilities such as beyond-shot-noise sensing with wavelengths for which efficient detectors are not available.

Related papers

SU(2)-in-SU(1,1) Nested Interferometer for High Sensitivity, Loss-Tolerant Quantum Metrology

Wei Du, Jia Kong, Guzhi Bao +8 more

We present experimental and theoretical results on a new interferometer topology that nests a SU(2) interferometer, e.g., a Mach-Zehnder or Michelson interferometer, inside a SU(1,1) interferometer, i.e., a Mach-Zehnder interferometer with parametric amplifiers in place of beam splitters. This SU(2)-in-SU(1,1) nested interferometer (SISNI) simultaneously achieves a high signal-to-noise ratio (SNR), sensitivity beyond the standard quantum limit (SQL) and tolerance to photon losses external to the interferometer, e.g., in detectors. We implement a SISNI using parametric amplification by four-wave mixing (FWM) in Rb vapor and a laser-fed Mach-Zehnder SU(2) interferometer. We observe path-length sensitivity with SNR 2.2 dB beyond the SQL at power levels (and thus SNR) 2 orders of magnitude beyond those of previous loss-tolerant interferometers. We find experimentally the optimal FWM gains and find agreement with a minimal quantum noise model for the FWM process. The results suggest ways to boost the in-practice sensitivity of high-power interferometers, e.g., gravitational wave interferometers, and may enable high-sensitivity, quantum-enhanced interferometry at wavelengths for which efficient detectors are not available.

arXiv:2004.14266•Physical Review Letters•Jan 20, 2022•52 citations

Overcoming detection loss and noise in squeezing-based optical sensing

Gaetano Frascella, Sascha Agne, Farid Ya. Khalili +1 more

Abstract Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. Squeezed states of atoms and light improve the sensing of the phase, magnetic field, polarization, mechanical displacement. They promise to considerably increase signal-to-noise ratio in imaging and spectroscopy, and are already used in real-life gravitational-wave detectors. But despite being more robust than other states, they are still very fragile, which narrows the scope of their application. In particular, squeezed states are useless in measurements where the detection is inefficient or the noise is high. Here, we experimentally demonstrate a remedy against loss and noise: strong noiseless amplification before detection. This way, we achieve loss-tolerant operation of an interferometer fed with squeezed and coherent light. With only 50% detection efficiency and with noise exceeding the level of squeezed light more than 50 times, we overcome the shot-noise limit by 6 dB. Sub-shot-noise phase sensitivity survives up to 87% loss. Application of this technique to other types of optical sensing and imaging promises a full use of quantum resources in these fields.

arXiv:2005.08843•npj Quantum Information•May 12, 2021•68 citations

SU(1,1) interferometry via four-wave mixing in Rb

Travis Horrom, Brian E. Anderson, Prasoon Gupta +1 more

Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].

•Jan 1, 2015•3 citations

Implementation of Polarization-Based Truncated SU (1,1) Interferometer in Hot Rb Vapor

Nikunj Prajapati, Irina V. Novikova

In this manuscript, we discuss the performance of a recently demonstrated polarization-based truncated SU(1,1) interferometer1 which can potentially generate polarization-entangled twin beams for applications in quantum communications or in quantum metrology as an interferometer with enhanced phase sensitivity. Using the intensity-squeezed twin beams generated via four-wave mixing (FWM) in hot Rubidium vapor, we report the detection of nearly -2 dB of noise reduction below the shot-noise in the joint-quadrature measurements in such interferometer. We also used this setup to confirms the non-classical nature of quantum correlations between the twin beams with an inseparability parameter I = 1:32±0:04 that falls below the classical limit of 2. One of the important advantages of the proposed interferometer is its better rejection of common-mode, technical, and environmental noises due to its intrinsic symmetry, which allows for squeezing and entanglement measurements at wide spectrum of detection frequencies from as low as 200 Hz (limited by 1=f electronic noise) to up to a few MHz (limited by the photodetector gain bandwidth).

Optical and Quantum Sensing and Precision Metrology II•Feb 25, 2020•0 citations

Phase sensing beyond the standard quantum limit with a variation on the SU(1,1) interferometer

Brian E. Anderson, Prasoon Gupta, Bonnie L. Schmittberger +4 more

An SU(1,1) interferometer replaces the beamsplitters in a Mach-Zehnder interferometer with nonlinear interactions and offers the potential of achieving high phase sensitivity in applications with low optical powers. We present a novel variation in which the second nonlinear interaction is replaced with balanced homodyne detection. The phase-sensing quantum state is a two-mode squeezed state produced by seeded four-wave-mixing in Rb vapor. Measurements as a function of operating point show that even with $\approx35~\%$ loss this device can surpass the standard quantum limit by 4~dB.

arXiv:1610.06891•Optica•Jun 30, 2017•168 citations

Loss-tolerant interferometry with squeezed light

Maria V. Chekhova, Gaetano Frascella, Sascha Agne +1 more

An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.

Emerging Imaging and Sensing Technologies for Security and Defence; and Advanced Manufacturing Technologies for Micro- and Nanosystems in Security and Defence•Sep 18, 2020•0 citations
The use of squeezing and entanglement allows advanced interferometers to detect signals that would otherwise be buried in quantum mechanical noise. High sensitivity instruments including magnetometers and gravitational wave detectors have shown enhanced signal-to-noise ratio (SNR) by injecting single-mode squeezed light into SU(2) interferometers, e.g. the Mach-Zehnder or Michelson topologies. The quantum enhancement in this approach is sensitive to losses, which break the fragile quantum correlations in the squeezed state. In contrast, SU(1,1) interferometers achieve quantum enhancement by noiseless amplification; they noiselessly increase the signal rather than reducing the quantum noise. Prior work on SU(1,1) interferometers has shown quantum-enhanced SNR11 and insensitivity to losses but to date has been limited to low powers and thus low SNR. Here we introduce a new interferometer topology, the SU(2)-in-SU(1,1) nested interferometer, that combines quantum enhancement, the high SNR possible with a SU(2) interferometer, and the loss tolerance of the SU(1,1) approach. We implement this interferometer using four-wave mixing in a hot atomic vapor and demonstrate 2:2(5) dB of quantum SNR enhancement, in a system with a phase variance nearly two orders of magnitude below that of any previous loss-tolerant enhancement scheme. The new interferometer enables new possibilities such as beyond-shot-noise sensing with wavelengths for which efficient detectors are not available.
We present experimental and theoretical results on a new interferometer topology that nests a SU(2) interferometer, e.g., a Mach-Zehnder or Michelson interferometer, inside a SU(1,1) interferometer, i.e., a Mach-Zehnder interferometer with parametric amplifiers in place of beam splitters. This SU(2)-in-SU(1,1) nested interferometer (SISNI) simultaneously achieves a high signal-to-noise ratio (SNR), sensitivity beyond the standard quantum limit (SQL) and tolerance to photon losses external to the interferometer, e.g., in detectors. We implement a SISNI using parametric amplification by four-wave mixing (FWM) in Rb vapor and a laser-fed Mach-Zehnder SU(2) interferometer. We observe path-length sensitivity with SNR 2.2 dB beyond the SQL at power levels (and thus SNR) 2 orders of magnitude beyond those of previous loss-tolerant interferometers. We find experimentally the optimal FWM gains and find agreement with a minimal quantum noise model for the FWM process. The results suggest ways to boost the in-practice sensitivity of high-power interferometers, e.g., gravitational wave interferometers, and may enable high-sensitivity, quantum-enhanced interferometry at wavelengths for which efficient detectors are not available.
Abstract Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. Squeezed states of atoms and light improve the sensing of the phase, magnetic field, polarization, mechanical displacement. They promise to considerably increase signal-to-noise ratio in imaging and spectroscopy, and are already used in real-life gravitational-wave detectors. But despite being more robust than other states, they are still very fragile, which narrows the scope of their application. In particular, squeezed states are useless in measurements where the detection is inefficient or the noise is high. Here, we experimentally demonstrate a remedy against loss and noise: strong noiseless amplification before detection. This way, we achieve loss-tolerant operation of an interferometer fed with squeezed and coherent light. With only 50% detection efficiency and with noise exceeding the level of squeezed light more than 50 times, we overcome the shot-noise limit by 6 dB. Sub-shot-noise phase sensitivity survives up to 87% loss. Application of this technique to other types of optical sensing and imaging promises a full use of quantum resources in these fields.
Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].
In this manuscript, we discuss the performance of a recently demonstrated polarization-based truncated SU(1,1) interferometer1 which can potentially generate polarization-entangled twin beams for applications in quantum communications or in quantum metrology as an interferometer with enhanced phase sensitivity. Using the intensity-squeezed twin beams generated via four-wave mixing (FWM) in hot Rubidium vapor, we report the detection of nearly -2 dB of noise reduction below the shot-noise in the joint-quadrature measurements in such interferometer. We also used this setup to confirms the non-classical nature of quantum correlations between the twin beams with an inseparability parameter I = 1:32±0:04 that falls below the classical limit of 2. One of the important advantages of the proposed interferometer is its better rejection of common-mode, technical, and environmental noises due to its intrinsic symmetry, which allows for squeezing and entanglement measurements at wide spectrum of detection frequencies from as low as 200 Hz (limited by 1=f electronic noise) to up to a few MHz (limited by the photodetector gain bandwidth).
An SU(1,1) interferometer replaces the beamsplitters in a Mach-Zehnder interferometer with nonlinear interactions and offers the potential of achieving high phase sensitivity in applications with low optical powers. We present a novel variation in which the second nonlinear interaction is replaced with balanced homodyne detection. The phase-sensing quantum state is a two-mode squeezed state produced by seeded four-wave-mixing in Rb vapor. Measurements as a function of operating point show that even with ≈35 %\approx35~\%≈35 % loss this device can surpass the standard quantum limit by 4~dB.
An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.